Radiology ; 253(1): 253-62, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19703867

ABSTRACT

PURPOSE: To evaluate the clinical usefulness of volumetric analysis at nonenhanced computed tomography (CT) as the sole method with which to follow up endovascular abdominal aortic aneurysm repair (EVAR) and to identify endoleaks causing more than 2% volumetric increase from the previous volume determination. MATERIALS AND METHODS: The study had institutional review board approval. Images were reviewed retrospectively in a HIPAA-compliant manner for 230 CT studies in 70 patients (11 women, 59 men; mean age, 74 years) who underwent EVAR. The scannning protocol consisted of three steps: (a) contrast material-enhanced CT angiography before endovascular stent placement, (b) contrast-enhanced CT angiography 0-3 months after repair to depict immediate complications, and (c) nonenhanced CT at 3, 6, and 12 months after repair. At each follow-up visit, immediate aortic volume analysis was performed. If the interval volumetric change was 2% or less, no further imaging was performed. If the volume increased by more than 2% on the nonenhanced CT image, contrast-enhanced CT angiography was performed immediately to identify the suspected endoleak. Confidence intervals (CIs) were obtained by using bootstrapping to account for repeated measurements in the same patients. RESULTS: Mean volume decrease was -3.2% (95% CI: -4.7%, -1.9%) in intervals without occurrence of a clinically relevant endoleak (n = 183). Types I and III high-pressure endoleaks (n = 10) showed a 10.0% (95% CI: 5.0%, 18.2%) interval volumetric increase. Type II low-pressure endoleaks (n = 37) showed a 5.4% (95% CI: 4.6%, 6.2%) interval volumetric increase. Endoleaks associated with minimal aortic volume increase of less than 2% did not require any intervention. This protocol reduced radiation exposure by approximately 57%-82% in an average-sized patient. CONCLUSION: Serial volumetric analysis of aortic aneurysm with nonenhanced CT serves as an adequate screening test for endoleak, causing volumetric increase of more than 2% from the volume seen at the previous examination.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/therapy , Cone-Beam Computed Tomography/methods , Stents , Aged , Contrast Media , Female , Follow-Up Studies , Humans , Male , ROC Curve , Retrospective Studies , Treatment Outcome
2.
AJR Am J Roentgenol ; 189(6): 1451-6, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18029884

ABSTRACT

OBJECTIVE: Disparate results from the existing large CT colonography (CTC) trials suggest that 2D polyp detection is less sensitive than 3D detection, but no direct evidence exists to support this claim. Our goal was to assess the sensitivity of primary 2D polyp detection with cases from the Department of Defense CTC screening trial and compare results with the primary 3D evaluation and previous 2D CTC trials. MATERIALS AND METHODS: Ten radiologists, blinded to polyp findings, retrospectively interpreted 730 consecutive colonoscopy-proven CTC cases in asymptomatic adults using a primary 2D approach, with 3D reserved for problem solving. Primary 2D CTC performance was compared with the primary 3D CTC results from the original trial of 1,233 asymptomatic adults. The 10 2D reviewers were significantly more experienced in CTC interpretation (> 100 cases interpreted) than the six reviewers from the original 3D trial. RESULTS: Primary 2D CTC sensitivity for adenomas > or = 6 mm was 44.1% (56/127), compared with 85.7% (180/210) at 3D (p < 0.001). Sensitivity of 2D CTC for adenomas > or = 10 mm was 75.0% (27/36) compared with 92.2% (47/51) at 3D (p = 0.027). Similar sensitivity trends were seen for the by-patient analysis and for all polyps at the 6-mm and 10-mm thresholds. By-patient specificity for 2D evaluation at the 10-mm threshold was 98.1% (676/689), compared with 97.4% (1,131/1,161) at 3D evaluation (p = 0.336). CONCLUSION: Primary 2D CTC is less sensitive than primary 3D CTC for polyp detection in low-prevalence screening cohorts. The disappointing 2D sensitivity in this study was very similar to results obtained with primary 2D evaluation in previous CTC trials.


Subject(s)
Algorithms , Colonic Polyps/diagnostic imaging , Colonography, Computed Tomographic/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Pattern Recognition, Automated/methods , Aged , Female , Humans , Male , Mass Screening/methods , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Single-Blind Method