Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Magn Reson Imaging ; 59(1): 311-322, 2024 01.
Article in English | MEDLINE | ID: mdl-37335079

ABSTRACT

BACKGROUND: The choice between different diffusion-weighted imaging (DWI) techniques is difficult as each comes with tradeoffs for efficient clinical routine imaging and apparent diffusion coefficient (ADC) accuracy. PURPOSE: To quantify signal-to-noise-ratio (SNR) efficiency, ADC accuracy, artifacts, and distortions for different DWI acquisition techniques, coils, and scanners. STUDY TYPE: Phantom, in vivo intraindividual biomarker accuracy between DWI techniques and independent ratings. POPULATION/PHANTOMS: NIST diffusion phantom. 51 Patients: 40 with prostate cancer and 11 with head-and-neck cancer at 1.5 T FIELD STRENGTH/SEQUENCE: Echo planar imaging (EPI): 1.5 T and 3 T Siemens; 3 T Philips. Distortion-reducing: RESOLVE (1.5 and 3 T Siemens); Turbo Spin Echo (TSE)-SPLICE (3 T Philips). Small field-of-view (FOV): ZoomitPro (1.5 T Siemens); IRIS (3 T Philips). Head-and-neck and flexible coils. ASSESSMENT: SNR Efficiency, geometrical distortions, and susceptibility artifacts were quantified for different b-values in a phantom. ADC accuracy/agreement was quantified in phantom and for 51 patients. In vivo image quality was independently rated by four experts. STATISTICAL TESTS: QIBA methodology for accuracy: trueness, repeatability, reproducibility, Bland-Altman 95% Limits-of-Agreement (LOA) for ADC. Wilcoxon Signed-Rank and student tests on P < 0.05 level. RESULTS: The ZoomitPro small FOV sequence improved b-image efficiency by 8%-14%, reduced artifacts and observer scoring for most raters at the cost of smaller FOV compared to EPI. The TSE-SPLICE technique reduced artifacts almost completely at a 24% efficiency cost compared to EPI for b-values ≤500 sec/mm2 . Phantom ADC 95% LOA trueness were within ±0.03 × 10-3 mm2 /sec except for small FOV IRIS. The in vivo ADC agreement between techniques, however, resulted in 95% LOAs in the order of ±0.3 × 10-3 mm2 /sec with up to 0.2 × 10-3 mm2 /sec of bias. DATA CONCLUSION: ZoomitPro for Siemens and TSE SPLICE for Philips resulted in a trade-off between efficiency and artifacts. Phantom ADC quality control largely underestimated in vivo accuracy: significant ADC bias and variability was found between techniques in vivo. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Head , Neck , Male , Humans , Reproducibility of Results , Phantoms, Imaging , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods
2.
Eur Radiol ; 30(11): 6303-6310, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32468106

ABSTRACT

OBJECTIVES: The aim of this study is to assess the diagnostic performance of a new MR sign, named the round window sign (RWS), to diagnose perilymphatic fistula (PLF) in a population of patients with chronic cochleo-vestibular symptoms, classified as definite or probable Menière's disease (MD). METHODS: A total of 164 patients (mean age 52 ± 35 years) with chronic cochleo-vestibular symptoms underwent MRI, between 4 and 5 h after intravenous gadoteric acid injection (Dotarem®, 0.1 mmol/kg). MRI exploration was carried out on a 3-T Achieva® TX scanner. We analyzed the presence of the RWS, defined as a nodular FLAIR high signal in the round window (RW) and the presence of associated saccular hydrops. When this RWS was present, a temporal bone CT scan was performed and the RW was analyzed. RESULTS: Of the 164 patients with definite MD (85 patients) or probable MD (79 patients), we found the RWS in 18 (11%), and 17/18 were classified into the group of probable MD. All these 18 patients showed other MR sequences considered as normal, including heavily weighted T2 imaging. Among these 18 patients, the temporal bone CT examination presented a filling of the RW in 13 patients (72%) and no filling of the RW in 5 patients (28%). Seven patients were surgically managed confirming in vivo the PLF diagnosis. The RWS was associated with the presence of a saccular hydrops in 4 cases. CONCLUSION: Delayed postcontrast 3D-FLAIR may reveal perilymphatic fistulae in patients with probable Menière's disease using the round window sign. KEY POINTS: • MRI with delayed acquisition can detect perilymphatic fistulae with perfect sensitivity, based on the presence of the round window sign. • This visual sign is only visible on a 3D-FLAIR sequence. • 3D-FLAIR sequence with delayed acquisition is more sensitive than temporal bone CT scan examination in detecting PLF.


Subject(s)
Contrast Media/chemistry , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Meniere Disease/diagnostic imaging , Vestibular Diseases/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media/pharmacology , Endolymphatic Hydrops/diagnosis , Female , Fistula/complications , Heterocyclic Compounds/chemistry , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Organometallic Compounds/chemistry , Vestibule, Labyrinth , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...