Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Injury ; 54(8): 110909, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37393776

ABSTRACT

INTRODUCTION: Atypical femoral fractures (AFFs) are associated with delayed union and higher reoperation rates. Axial dynamization of intramedullary nails is hypothesized to reduce time-to-union (TTU) and fixation failure as compared to static locking. METHODS: Consecutive acutely displaced AFFs fixed with long intramedullary nails across five centres between 2006 and 2021 with a minimum postoperative follow-up of three months were retrospectively reviewed. The primary outcome was TTU, compared between AFFs treated with dynamically or statically locked intramedullary nails. Fracture union was defined as a modified Radiographic Union Score for Tibial fractures score of 13 or greater. Secondary outcomes involved revision surgery and treatment failure, defined as non-union beyond 18 months or revision internal fixation for mechanical reasons. RESULTS: A total of 236 AFFs (127 dynamically locked and 109 statically locked) were analysed with good interobserver reliability of fracture union assessment (intraclass correlation coefficient = 0.89; 95% CI = 0.82-0.98). AFFs treated with dynamized nails had significantly shorter median TTU (10.1 months; 95% CI = 9.24-10.96 vs 13.0 months; 95% CI = 10.60-15.40) (log-rank test, p = 0.019). Multivariate Cox regression revealed that dynamic locking was independently associated with greater likelihood of fracture union within 24 months (p = 0.009). Reoperations were less frequent in the dynamic locking group (18.9% vs 28.4%), although the difference was not statistically significant (p = 0.084). Static locking was an independent risk factor for reoperation (p = 0.049), as were varus reduction and lack of teriparatide use within three months of surgery. Static locking also demonstrated a higher frequency of treatment failure (39.4% vs 22.8%, p = 0.006) and was an independent predictor of treatment failure in logistic regression (p = 0.018). Other factors associated with treatment failure included varus reduction and open reduction. CONCLUSIONS: Dynamic locking of intramedullary nails in AFFs is associated with faster time to union, lower rate of non-union, and fewer treatment failures.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Reoperation , Follow-Up Studies , Retrospective Studies , Treatment Outcome , Reproducibility of Results , Bone Nails , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery
2.
BMC Musculoskelet Disord ; 21(1): 413, 2020 Jun 29.
Article in English | MEDLINE | ID: mdl-32600366

ABSTRACT

BACKGROUND: Plate fixation is frequently used to treat displaced midshaft clavicular fractures, however the ideal plate choice remains subject to discussion; reconstruction locking compression plates (RLCPs) are cheaper and can be easily contoured, whereas anatomically pre-contoured locking compression plates (ALCPs) are thought to provide better stability and therefore lower rates of mechanical failure. To compare the incidence of mechanical failures, functional and radiological outcomes in patients with midshaft clavicular fractures treated with ALCPs versus RLCPs. METHODS: A propensity score matched retrospective cohort study was conducted across two centers. One hundred and six consecutively recruited patients with displaced midshaft clavicular fractures, who were treated with plate fixation and had a minimum follow-up of 6 months, were matched on gender, age, fracture grading, energy of injury, and fracture location. The resulting groups included 53 ALCP-treated fractures and 53 matched controls treated with RLCPs. RESULTS: During a mean follow-up of 20.5 months, there were no implant deformities in the ALCP group whereas the RLCP group had 6 patients (11.3%, p = 0.012) with implant deformities (5 occurrences of plate bending with fracture union, and 1 plate breakage with nonunion). Despite the higher rate of plate deformities in the RLCP group, there were no statistically significant differences in number of patients recovering full shoulder range of motion (ALCP 90.6%, RLCP 88.7%, p = 0.751), incidence of rest pain (ALCP 13.2%, RLCP 9.4%, p = 0.542), or implant removals (ALCP 49.1%, RLCP 56.6%, p = 0.439). CONCLUSION: ALCPs may be superior to RLCPs in terms of implant stability but appear to produce similar clinical results.


Subject(s)
Bone Plates , Clavicle/injuries , Fractures, Bone/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Screws , Clavicle/surgery , Device Removal , Female , Fracture Fixation, Internal/instrumentation , Fracture Healing , Fractures, Bone/diagnostic imaging , Hong Kong , Humans , Male , Middle Aged , Propensity Score , Radiography , Range of Motion, Articular , Retrospective Studies , Treatment Outcome , Young Adult
3.
Geriatr Orthop Surg Rehabil ; 10: 2151459319864736, 2019.
Article in English | MEDLINE | ID: mdl-31384487

ABSTRACT

BACKGROUND: Atypical femoral fractures have been demonstrated to have high risks of reoperation and nonunion. The aim of this study is to evaluate whether the quality of reduction following operative fixation of atypical femoral fracture predicts failure. METHODS: This is a 6.5-year retrospective review of atypical femoral fractures from 2 centers in a high-income region. A total of 56 patients with 66 fractures met our inclusion criteria. The quality of reduction was evaluated from postoperative films according to Hoskins' modification of Baumgartner criteria for subtrochanteric fractures. Our primary outcome measure was failure of treatment, defined as either reoperation or nonunion at 12 months. RESULTS: There were a total of 8 reoperations (12% of all fractures) and 8 nonunion (12% of all fractures), affecting a total of 12 fractures (18%) in 12 patients (21%). Closed reduction (P = .04) and poor quality of reduction (P = .0227 Fisher exact test) are statistically significant risk factors for failure. CONCLUSIONS: An aim for anatomical reduction with both <4 mm maximal cortical displacement and <10° angulation can improve the operative outcome of atypical femoral fractures. The addition of open reduction may be beneficial.

4.
Geriatr Orthop Surg Rehabil ; 5(1): 14-7, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24660094

ABSTRACT

We report 2 cases of atypical femoral fracture displacement despite treatment with intramedullary (IM) nailing. Both patients had received more than 3 years of bisphosphonates. One patient had prophylactic fixation of an atypical femur fracture due to intractable pain. The other had undergone nailing previously for a traumatic shaft fracture. The patient then received bisphosphonate later and sustained an atypical fracture with the nail in place. Both femoral nails were slotted, cannulated stainless steel piriformis entry designs. These 2 cases are among the first reported failures of IM fixation in preventing displacement of a bisphosphonate stress fracture. We advice caution when using slotted nails in prophylaxis of atypical femur fractures because of its significantly reduced torsional stiffness compared to modern nonopen sectioned nails.

5.
J Orthop Surg (Hong Kong) ; 20(2): 162-5, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22933671

ABSTRACT

PURPOSE: To assess the effect of hyaluronic acid instillation after arthroscopic anterior cruciate ligament (ACL) reconstruction for improving pain, range of movement, and function of the knee. METHODS: 28 men and 4 women underwent arthroscopic ACL reconstruction for isolated ACL rupture (partial or complete) and instability after recreational sports injury 2 to 120 months earlier. They were randomised to undergo arthroscopic ACL reconstruction followed by intra-articular viscoseal instillation (13 men and 3 women) or arthroscopic ACL reconstruction alone (15 men and 1 woman). The knee injury osteoarthritis outcome score (for pain, symptoms, activities of daily living, sport and recreation function, and quality of life), range of movement, knee circumference, and analgesic use were assessed on days -1, 1, and 2, and weeks 2, 6 and 12. RESULTS: Patient demographics were similar at baseline. At postoperative days 1 and 2, all subscales of the knee injury osteoarthritis outcome score (except for quality of life) were significantly higher in the viscoseal group. At weeks 2, 6, and 12, improvement in both groups equalised. Knee swelling (change in knee circumference) was significantly less in the viscoseal group at days 1 and 2 (p=0.009 and p=0.038, respectively, Mann-Whitney U test). Only one patient in the viscoseal group had a limited range of movement. No patient developed any adverse reaction. CONCLUSION: Intra-articular viscoseal instillation improved pain control and swelling 2 days after arthroscopic ACL reconstruction.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Arthroscopy , Hyaluronic Acid/administration & dosage , Viscosupplements/administration & dosage , Adult , Double-Blind Method , Female , Humans , Instillation, Drug , Male , Postoperative Care
6.
Blood ; 113(6): 1241-9, 2009 Feb 05.
Article in English | MEDLINE | ID: mdl-18927441

ABSTRACT

The transcription factor Runx1 is essential for the development of definitive hematopoietic stem cells (HSCs) during vertebrate embryogenesis and is transcribed from 2 promoters, P1 and P2, generating 2 major Runx1 isoforms. We have created 2 stable runx1 promoter zebrafish-transgenic lines that provide insight into the roles of the P1 and P2 isoforms during the establishment of definitive hematopoiesis. The Tg(runx1P1:EGFP) line displays fluorescence in the posterior blood island, where definitive erythromyeloid progenitors develop. The Tg(runx1P2:EGFP) line marks definitive HSCs in the aorta-gonad-mesonephros, with enhanced green fluorescent protein-labeled cells later populating the pronephros and thymus. This suggests that a function of runx1 promoter switching is associated with the establishment of discrete definitive blood progenitor compartments. These runx1 promoter-transgenic lines are novel tools for the study of Runx1 regulation and function in normal and malignant hematopoiesis. The ability to visualize and isolate fluorescently labeled HSCs should contribute to further elucidating the complex regulation of HSC development.


Subject(s)
Core Binding Factor Alpha 2 Subunit/physiology , Erythroid Precursor Cells/cytology , Green Fluorescent Proteins/metabolism , Promoter Regions, Genetic/genetics , Zebrafish Proteins/physiology , Animals , Animals, Genetically Modified , Blotting, Southern , Cell Lineage , Embryo, Nonmammalian/cytology , Embryo, Nonmammalian/metabolism , Gene Expression Regulation, Developmental , Green Fluorescent Proteins/genetics , Hematopoiesis , Immunoenzyme Techniques , In Situ Hybridization , Mesonephros/cytology , Mesonephros/embryology , Protein Isoforms , Zebrafish
7.
Dev Dyn ; 228(3): 323-36, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14579373

ABSTRACT

We cloned zebrafish runx3/aml2/cbfa3 and examined its expression and function during embryogenesis. In the developing embryo, runx3 is dynamically expressed in hematopoietic, neuronal, and cartilaginous tissues. Hematopoietic expression of runx3 commences late in embryogenesis in the ventral tail intermediate cell mass and later colocalizes with spi1 and lyz in circulating blood cells. In the cloche mutant, hematopoietic expression was absent, suggesting that Runx3 functions downstream of cloche in a hematopoietic pathway. Neuronal tissues expressing runx3 include the trigeminal ganglia and Rohon-Beard neurons. Runx3 appears to contribute to normal development of primitive and definitive hematopoietic cells. When Runx3 function was compromised using morpholino oligonucleotides, a reduction in the number of mature blood cells was observed. Furthermore, Runx3 depletion decreased runx1 expression in the ventral wall of the dorsal aorta and reduced the number of spi1- and lyz-containing blood cells. Conversely, ubiquitous overexpression of runx3 led to an increase in primitive blood cell numbers, together with an increase in runx1-expressing cells in the ventral wall of the dorsal aorta. We propose a role for Runx3 in the regulation of blood cell numbers.


Subject(s)
DNA-Binding Proteins/genetics , Gene Expression Regulation, Developmental/genetics , Hematopoiesis/physiology , Transcription Factors/genetics , Animals , Cloning, Molecular , Core Binding Factor Alpha 3 Subunit , DNA-Binding Proteins/metabolism , Embryo, Nonmammalian/physiology , Hematopoiesis/genetics , Molecular Sequence Data , Neurons/physiology , Recombinant Proteins/metabolism , Transcription Factors/metabolism , Zebrafish/embryology , Zebrafish/genetics , Zebrafish Proteins/genetics , Zebrafish Proteins/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...