Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Nanobioscience ; 21(1): 65-74, 2022 01.
Article in English | MEDLINE | ID: mdl-34516379

ABSTRACT

BACKGROUND: Fluctuation in serotonin (5-HT) level is an essential manifestation of several neurological disorders. In view of such importance, it is necessary to monitor the levels of 5-HT with good sensitivity, selectivity, affordability and low response time. Zinc oxide (ZnO) based field effect transistors (FET) with attributes like minimized noise levels and large on-off ratio are regarded as emerging high performance biosensor platforms. However, their response is significantly non-linear and there has been no appreciable endeavor for improving the non-linearity. METHOD: In this paper, we have introduced embedded gate electrode encompassing the channel of the FET which improves the uniformity in electric field line distribution through the electrolyte and proportionately enhances the capture of target biomolecule at ultra-low concentrations, thereby increasing the linearity. Further, we have incorporated the optimized parameters of ZnO nanorods reported previously, for rapid and selective detection of 5-HT. RESULTS: It has been observed that the fabricated ZnO FET biosensor lowers the detection limit down to 0.1fM which is at least one order of magnitude lower than the existing reports. The sensor also has wide linear range from 0.1fM to 1nM with a detection time of about 20 minutes. CONCLUSION: The proposed zinc oxide nanorod-based sensor can be used as an excellent tool for future diagnosis of neurological disorders.


Subject(s)
Biosensing Techniques , Nanotubes , Zinc Oxide , Electrodes , Serotonin
2.
Sci Rep ; 11(1): 2962, 2021 02 03.
Article in English | MEDLINE | ID: mdl-33536505

ABSTRACT

Developing point-of-care (PoC) diagnostic platforms for carcinoembryonic antigen detection is essential. However, thefew implementations of transferring the signal amplification strategies in electrochemical sensing on paper-based platforms are not satisfactory in terms of detection limit (LOD). In the quest for pushing down LOD, majority of the research has been targeted towards development of improved nanostructured substrates for entrapping more analyte molecules and augmenting the electron transfer rate to the working electrode. But, such approaches have reached saturation. This paper focuses on enhancing the mass transport of the analyte towards the sensor surface through the application of an electric field, in graphene-ZnO nanorods heterostructure. These hybrid nanostructures have been deposited on flexible polyethylene terephthalate substrates with screen printed electrodes for PoC application. The ZnO nanorods have been functionalized with aptamers and the working sensor has been integrated with smartphone interfaced indigenously developed low cost potentiostat. The performance of the system, requiring only 50 µl analyte has been evaluated using electrochemical impedance spectroscopy and validated against commercially available ELISA kit. Limit of detection of 1 fg/ml in human serum with 6.5% coefficient of variation has been demonstrated, which is more than three orders of magnitude lower than the existing attempts on PoC device.


Subject(s)
Carcinoembryonic Antigen/blood , Electrochemical Techniques/instrumentation , Nanotubes/chemistry , Point-of-Care Systems , Point-of-Care Testing , Aptamers, Nucleotide/chemistry , Graphite/chemistry , Humans , Limit of Detection , Zinc Oxide/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...