1.
J Anaesthesiol Clin Pharmacol ; 40(1): 95-100, 2024.
Article in English | MEDLINE | ID: mdl-38666173

ABSTRACT

Background and Aims: LMA ProSeal (PLMA) is a commonly used airway maintenance device in elective procedures and is routinely inserted from the head-end of the patient. It is also used in pre-hospital emergencies where it may not always be possible to access the head-end. This study aims to compare the insertion characteristics of PLMA when inserted while standing, either at the head-end or from the front. Material and Methods: After institutional ethics committee approval, 60 consenting patients of either sex, between 18 and 60 years, ASA class I/II, and scheduled to undergo elective surgeries were randomly allocated to either group H (head-end insertion) or group F (front-end insertion). Patients with anticipated difficult airway, chronic respiratory disease, obesity, and who were pregnant were excluded. Insertion time, ease of insertion, fiber optic view, ease of drain tube insertion, number of attempts and success rate were noted. Normally distributed quantitative variables were compared using t-test, and qualitative variables were compared using Chi-squared test. A P < 0.05 was considered significant. Results: Insertion time in group H (23.76 ± 4.48 s) was lesser than in group F (30.53 ± 6.23s) (P = 0.027). Ease of insertion (P = 0.052), fiber optic view, ease of drain tube placement (P = 1.000), and number of attempts (P = 1.000) were comparable among the groups. Conclusion: Although the insertion time from the front is longer than from the head-end, the other insertion characteristics of PLMA including ease of its insertion, placement and success rate of placement are similar when it is inserted from the front or from the head-end. It is an appropriate airway device for securing the airway when the head-end is inaccessible.

2.
J Anaesthesiol Clin Pharmacol ; 39(3): 451-457, 2023.
Article in English | MEDLINE | ID: mdl-38025583

ABSTRACT

Background and Aims: Pre-eclamptic parturients may have an exaggerated response to vasopressors. This study compares the efficacy of a 50 µg fixed bolus of phenylephrine for treatment of post-spinal hypotension in pre-eclamptic versus normotensive parturients. Material and Methods: After written informed consent and ethics committee approval, 30 normotensive and 30 pre-eclamptic parturients between 18 and 40 years with singleton term pregnancy about to undergo cesarean section (CS) under spinal anesthesia were included. Post-spinal hypotension was treated with a 50 µg fixed bolus of phenylephrine. The cumulative dose of phenylephrine, the number of boluses, and the median dose required to treat the first hypotensive episode, total number of hypotensive episodes, maternal side effects, neonatal appearance, pulse, grimace, activity, and respiration (APGAR) scores, and umbilical arterial cord blood pH were noted. Statistical analysis was done using Student's t-test, Mann-Whitney U-test, Chi-square test/Fisher's exact test as appropriate. A P <0.05 was considered significant. Results: The cumulative dose and number of boluses of phenylephrine required to treat post-spinal hypotension were comparable. The median dose required to treat the first episode of post-spinal hypotension was also similar (p = 0.792). The time to develop the first hypotensive episode was significantly earlier for group N (p = 0.002). The efficacy of a single fixed bolus of 50 µg phenylephrine was similar in both groups (p = 1.000). Neonatal median APGAR scores at 1 min after birth were significantly higher for group N (p = 0.016). Conclusion: A fixed-dose bolus of 50 µg phenylephrine is safe and effective in treating post-spinal hypotension in pre-eclampsia. The efficacy of phenylephrine is comparable in pre-eclamptic and normotensive parturients.

SELECTION OF CITATIONS
SEARCH DETAIL
...