Pacing Clin Electrophysiol ; 31(2): 251-2, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18233982

ABSTRACT

This report describes a patient who underwent cardiac resynchronization therapy (CRT) in the setting of a severe stenosis in the lateral coronary vein that prevented passage of a left ventricular lead. The stenosis was unresponsive to standard compliant balloon dilatation but was successfully treated with a noncompliant balloon. Venoplasty with noncompliant balloon should be considered for resistant coronary vein stenosis encountered during CRT device implantation.


Subject(s)
Angioplasty, Balloon/methods , Cardiac Pacing, Artificial/methods , Coronary Stenosis/therapy , Electrodes, Implanted , Pacemaker, Artificial , Coronary Angiography , Humans , Male , Middle Aged