Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Thorac Surg ; 109(6): e453-e456, 2020 06.
Article in English | MEDLINE | ID: mdl-31987827

ABSTRACT

Accidental entry into the right ventricular cavity is a common occurrence during exposure of the intra-myocardial left anterior descending artery. Several techniques have been described for repair of the perforation. Although these methods can be used, there is still a danger of persistent bleeding or distal ischemia. We describe a method that is safe and reproducible.


Subject(s)
Cardiac Surgical Procedures/methods , Coronary Vessels/surgery , Heart Injuries/surgery , Heart Ventricles/surgery , Suture Techniques , Humans
2.
J Indian Prosthodont Soc ; 19(2): 141-148, 2019.
Article in English | MEDLINE | ID: mdl-31040548

ABSTRACT

AIM AND OBJECTIVES: The purpose of this study was to investigate the effect of dentin surface treatment with aluminum oxide air abrasion and Er:YAG laser on tensile bond strength of metal crowns. Metal crowns were luted with conventional glass ionomer cement (GIC) in the teeth with reduced crown height, where preparation geometry did not provide optimal retention form. MATERIALS AND METHODS: Forty-eight human premolars were prepared to receive metal crowns and were randomly divided into four groups for tensile bond strength testing. Group A: Untreated dentin luted with self-adhesive composite resin cement as positive control; Group B: Untreated dentin luted with GIC as negative control; Group C: Surface treatment with 50 µm aluminum oxide air abrasion and luted with GIC; Group D: Surface treatment with Er:YAG laser (λ =2.94 mm) with a total energy 84.88 J/cm2 of (60 mJ/pulse, 10 Hz, 60 pulses, and 100 µs pulse width) and luted with GIC. The cemented specimens were thermocycled and later subjected to axial load in a universal testing machine at 0.5 mm/min cross-head speed for tensile testing. Scanning electron microscopic evaluation of dentin surface treatment and cement-dentin interface was also done in representative specimens. RESULTS: One-way analysis of variance showed statistically significant difference among/within the groups (P < 0.001). Tukey's post hoc test presented significant increased tensile bond strength of Er:YAG laser group. Air abrasion group showed no significant increase in tensile bond strength values (P = 0.033). CONCLUSION: Dentin surface treatment with Er:YAG laser significantly improved the tensile bond strength of luting GIC compared to air-abraded and untreated dentin.

3.
J Indian Prosthodont Soc ; 18(3): 201-211, 2018.
Article in English | MEDLINE | ID: mdl-30111908

ABSTRACT

PURPOSE: This systematic review aimed to evaluate retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches. METHODS: The relevant articles were retrieved from MEDLINE (PubMed), Cochrane Library, and EBSCO electronic databases for articles published from January 1995 to January 2016 and were restricted to randomized controlled trials and retrospective and prospective studies on human subjects that were reported in English. A further hand search was conducted on individual journals and reference list of the articles found. Reviewed studies which reported retention failures in fixed implant-supported prostheses using screw and cement retention mechanism. Information on the type and nature of restoration, as well as different luting cement, were also collected. RESULTS: Thirty-three articles were finalized, 20 short-term clinical studies (up to 5 years) and 13 long-term studies (≥5 years). Out of 33 studies, 16 studies were included in meta-analysis, 8 in short-term and 8 in long-term studies. The results of the meta-analysis for short-term studies showed statistically significant difference between cement-retained and screw-retained prosthesis, with the forest plot favoring cement-retained prostheses (risk ratio [RR]: 0.26; confidence interval [CI]: 0.09-0.74; P < 0.0001; I2 = 79%). In long-term studies, the forest plot revealed statistically significant difference between both retention systems favoring cement-retained prostheses (RR: 0.31; CI: 0.13-0.76; P = 0.03; I2 = 56%). CONCLUSION: Analysis of the short- and long-term studies shows lesser retention failures with cement-retained prostheses when compared to screw-retained prostheses. Further, multicentric, high-quality randomized controlled studies with long-term observations and modified cementation protocols can yield higher grades of recommendation to avoid retention failures.

SELECTION OF CITATIONS
SEARCH DETAIL
...