ABSTRACT
Objective:The ability to generate electric fields in specific targets remotely would transform manipulations of processes that rest on electrical signaling.Approach:This article shows that focal electric fields are generated from distance by combining two orthogonal, remotely applied energies-magnetic and focused ultrasonic fields. The effect derives from the Lorentz force equation applied to magnetic and ultrasonic fields.Main results:We elicited this effect using standard hardware and confirmed that the generated electric fields align with the Lorentz equation. The effect significantly and safely modulated human peripheral nerves and deep brain regions of non-human primates.Significance:This approach opens a new set of applications in which electric fields are generated at high spatiotemporal resolution within intact biological tissues or materials, thus circumventing the limitations of traditional electrode-based procedures.
Subject(s)
Brain , Ultrasonics , Animals , Brain/physiology , Electric StimulationABSTRACT
PURPOSE: To demonstrate that magnetic resonance-guided focused ultrasound (MRgFUS) facilitates blood-spinal cord barrier (BSCB) permeability and develop observer-independent MRI quantification of BSCB permeability after MRgFUS for spinal cord injury (SCI). METHODS: Noninjured Sprague-Dawley rats (n = 3) underwent MRgFUS and were administered Evans blue post-MRgFUS to confirm BSCB opening. Absorbance was measured by spectrophotometry and correlated with its corresponding image intensity. Rats (n = 21) underwent T8-T10 laminectomy and extradural compression of the spinal cord (23g weighted aneurysm-type clip, 1 min). The intervention group (n = 11) was placed on a preclinical MRgFUS system, administered microbubbles (Optison, 0.2 mL/kg), and received 3 MRgFUS sonications (25 ms bursts, 1 Hz pulses for 3 min, 3 acoustic W, approximately 1.0-2.1 MPa peak pressure as measured via hydrophone). The sham group (n = 10) received equivalent procedures with no sonications. T1w MRI was obtained both pre- and post-MRgFUS BSCB opening. Spinal cords were segmented manually or semiautomatically and a Pearson correlation with P ≤ 0.001 was used to correlate the two segmentation methods. MRgFUS sonication and control regions intensity values were evaluated with a paired t-test with a P ≤ 0.01. RESULTS: Semiautomatic segmentation reduced computational time by 95% and was correlated with manual segmentation (Pearson = 0.92, P < 0.001, n = 71 regions). In the noninjured rat group, Evans blue absorbance correlated with image intensity in the MRgFUS and control regions (Pearson = 0.82, P = 0.02, n = 6). In rats that underwent the SCI procedure, an increase in signal intensity in the MRgFUS targeted region relative to control was seen in all SCI rats (10.65 ± 12.4%, range: 0.96-43.9%, n = 11, P = 0.002). SCI sham MRgFUS revealed no change (0.63 ± 0.52%, 95% CI 0.320.95, n = 10). This result was significant between both groups (P = 0.003). CONCLUSION: The implemented semiautomatic segmentation procedure improved data analysis efficiency. Quantitative methods using contrast-enhanced MRI with histological validation are sensitive for detection of blood-spinal cord barrier opening induced by magnetic resonance-guided focused ultrasound.