Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Org Lett ; 26(26): 5447-5452, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38896796

ABSTRACT

Interest in electrocatalytic bioconjugation reactions has surged, particularly for modifying tryptophan and tyrosine residues in proteins. We used a cost-effective graphite felt electrode and low-current methodology to achieve selective bioconjugation of tryptophan with thiophenols, yielding up to 92%. This method exclusively labeled tryptophan residues and incorporated fluorinated tryptophan for NMR analysis. Eight polypeptides, including lanreotide and leuprorelin, were effectively coupled, demonstrating the method's versatility and potential for novel diagnostic and therapeutic agents.


Subject(s)
Peptides , Tryptophan , Tryptophan/chemistry , Peptides/chemistry , Electrochemical Techniques , Molecular Structure , Somatostatin/chemistry , Somatostatin/analogs & derivatives , Peptides, Cyclic/chemistry , Electrodes
2.
Sci Rep ; 13(1): 10025, 2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37340014

ABSTRACT

We investigated the effectiveness of using methylboronic acid MIDA ester (ADM) as an additive in an electrolyte to enhance the overall electrochemical and material properties of an LNCAO (LiNi0.8Co0.15Al0.05O2) cathode. The cyclic stability of the cathode material measured at 40 °C (@ 0.2 C) showed an enhanced capacity of 144.28 mAh g-1 (@ 100 cycles), a capacity retention of 80%, and a high coulombic efficiency (99.5%), in contrast to these same properties without the electrolyte additive (37.5 mAh g-1, ~ 20%, and 90.4%), thus confirming the effectiveness of the additive. A Fourier transform infrared spectroscopy (FTIR) analysis distinctly showed that the ADM additive suppressed the EC-Li+ ion coordination (1197 cm-1 and 728 cm-1) in the electrolyte, thereby improving the cyclic performance of the LNCAO cathode. The cathode after 100 charge/discharge cycles revealed that the ADM-containing system exhibited better surface stability of the grains in the LNCAO cathode, whereas distinct cracks were observed in the system without the ADM in the electrolyte. A transmission electron microscopy (TEM) analysis revealed the presence of a thin, uniform and dense cathode electrolyte interface (CEI) film on the surface of LNCAO cathode. An operando synchrotron X-ray diffraction (XRD) test identified the high structural reversibility of the LNCAO cathode with a CEI layer formed by the ADM, which effectively maintained the structural stability of the layered material. The additive effectively inhibited the decomposition of electrolyte compositions, as confirmed by X-ray photoelectron spectroscopy (XPS).

3.
Lab Chip ; 13(7): 1333-41, 2013 Apr 07.
Article in English | MEDLINE | ID: mdl-23381092

ABSTRACT

A dual-chip, multidimensional micro gas chromatographic module was designed, built and evaluated. Column chips were fabricated on a silicon wafer with an etched rectangular channel 100 µm (width) × 250 µm (depth) using a deep reactive ion etching (DRIE) process. The column chip for the first GC dimension was 3 m long and was coated with polydimethylsiloxane (DB-1) as the stationary phase. The columns on the second dimensional chip were etched with the same width and depth as the first chip, but the flow channel was split into three parallel columns, 1 m long, on the same sized silicon chip (i.e., 3 cm × 3 cm). These three parallel columns on the second chip were coated with polyethylene oxide (DB-Wax), trifluoropropylpolymethylsilicone (OV-210) and cyanopropylmethylphenylmethylpolysilicone (OV-225), accordingly, in order to provide diversified chromatographic retention. These two chips were connected via a stop-flow configuration to simultaneously generate multiple two-dimensional gas chromatograms for every analysis. This stop-flow µGC × µGCs design allowed the first column to function as a pre-separator and as a sequencing injector for the second parallel-separation chip. Fifteen volatile organic compounds with boiling points that ranged from 80-131 °C with various functional groups were tested using this µGC × µGCs module. Three discrete 2-D chromatograms were generated simultaneously, which demonstrated the advantages of simultaneously combining GC × GC with parallel separation GCs in microchip chromatography. The total traveling length in the column was only 4 m for each eluted peak and fully resolved separation was achieved through the cross reference among triplet 2-D chromatograms.

SELECTION OF CITATIONS
SEARCH DETAIL
...