Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Anesthesiology ; 137(6): 704-715, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36129686

ABSTRACT

BACKGROUND: Improper endotracheal tube (ETT) positioning is frequently observed and potentially hazardous in the intensive care unit. The authors developed a deep learning-based automatic detection algorithm detecting the ETT tip and carina on portable supine chest radiographs to measure the ETT-carina distance. This study investigated the hypothesis that the algorithm might be more accurate than frontline critical care clinicians in ETT tip detection, carina detection, and ETT-carina distance measurement. METHODS: A deep learning-based automatic detection algorithm was developed using 1,842 portable supine chest radiographs of 1,842 adult intubated patients, where two board-certified intensivists worked together to annotate the distal ETT end and tracheal bifurcation. The performance of the deep learning-based algorithm was assessed in 4-fold cross-validation (1,842 radiographs), external validation (216 radiographs), and an observer performance test (462 radiographs) involving 11 critical care clinicians. The performance metrics included the errors from the ground truth in ETT tip detection, carina detection, and ETT-carina distance measurement. RESULTS: During 4-fold cross-validation and external validation, the median errors (interquartile range) of the algorithm in ETT-carina distance measurement were 3.9 (1.8 to 7.1) mm and 4.2 (1.7 to 7.8) mm, respectively. During the observer performance test, the median errors (interquartile range) of the algorithm were 2.6 (1.6 to 4.8) mm, 3.6 (2.1 to 5.9) mm, and 4.0 (1.7 to 7.2) mm in ETT tip detection, carina detection, and ETT-carina distance measurement, significantly superior to that of 6, 10, and 7 clinicians (all P < 0.05), respectively. The algorithm outperformed 7, 3, and 0, 9, 6, and 4, and 5, 5, and 3 clinicians (all P < 0.005) regarding the proportions of chest radiographs within 5 mm, 10 mm, and 15 mm error in ETT tip detection, carina detection, and ETT-carina distance measurement, respectively. No clinician was significantly more accurate than the algorithm in any comparison. CONCLUSIONS: A deep learning-based algorithm can match or even outperform frontline critical care clinicians in ETT tip detection, carina detection, and ETT-carina distance measurement.


Subject(s)
Deep Learning , Adult , Humans , Trachea , Intubation, Intratracheal , Radiography , Mediastinum
2.
Diagnostics (Basel) ; 12(8)2022 Aug 07.
Article in English | MEDLINE | ID: mdl-36010263

ABSTRACT

In intensive care units (ICUs), after endotracheal intubation, the position of the endotracheal tube (ETT) should be checked to avoid complications. The malposition can be detected by the distance between the ETT tip and the Carina (ETT-Carina distance). However, it struggles with a limited performance for two major problems, i.e., occlusion by external machine, and the posture and machine of taking chest radiographs. While previous studies addressed these problems, they always suffered from the requirements of manual intervention. Therefore, the purpose of this paper is to locate the ETT tip and the Carina more accurately for detecting the malposition without manual intervention. The proposed architecture is composed of FCOS: Fully Convolutional One-Stage Object Detection, an attention mechanism named Coarse-to-Fine Attention (CTFA), and a segmentation branch. Moreover, a post-process algorithm is adopted to select the final location of the ETT tip and the Carina. Three metrics were used to evaluate the performance of the proposed method. With the dataset provided by National Cheng Kung University Hospital, the accuracy of the malposition detected by the proposed method achieves 88.82% and the ETT-Carina distance errors are less than 5.333±6.240 mm.

3.
Diagnostics (Basel) ; 11(1)2020 Dec 24.
Article in English | MEDLINE | ID: mdl-33374307

ABSTRACT

BACKGROUND AND OBJECTIVE: In the first trimester of pregnancy, fetal growth, and abnormalities can be assessed using the exact middle sagittal plane (MSP) of the fetus. However, the ultrasound (US) image quality and operator experience affect the accuracy. We present an automatic system that enables precise fetal MSP detection from three-dimensional (3D) US and provides an evaluation of its performance using a generative adversarial network (GAN) framework. METHOD: The neural network is designed as a filter and generates masks to obtain the MSP, learning the features and MSP location in 3D space. Using the proposed image analysis system, a seed point was obtained from 218 first-trimester fetal 3D US volumes using deep learning and the MSP was automatically extracted. RESULTS: The experimental results reveal the feasibility and excellent performance of the proposed approach between the automatically and manually detected MSPs. There was no significant difference between the semi-automatic and automatic systems. Further, the inference time in the automatic system was up to two times faster than the semi-automatic approach. CONCLUSION: The proposed system offers precise fetal MSP measurements. Therefore, this automatic fetal MSP detection and measurement approach is anticipated to be useful clinically. The proposed system can also be applied to other relevant clinical fields in the future.