Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Diabetes ; 16(4): e13536, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38599884

ABSTRACT

AIMS: It is not clear whether there are differences in glycemic control between the Equil patch and the MMT-712 insulin pump. Our objective was to compare two types of insulin pumps in the treatment of type 2 diabetes mellitus (T2DM), using continuous glucose monitoring (CGM) metrics and profiles. METHODS: This was a randomized case-crossover clinical trial. Participants were hospitalized and randomly allocated to two groups and underwent two types of insulin pump treatments (group A: Equil patch-Medtronic MMT-712 insulin pump; group B: Medtronic MMT-712-Equil patch insulin pump) separated by a 1-day washout period. Glycemic control was achieved after 7-8 days of insulin pump therapy. Each patient received CGM for 5 consecutive days (from day 1 to day 5). On day 3 of CGM performance, the Equil patch insulin pump treatment was switched to Medtronic MMT-712 insulin pump treatment at the same basal and bolus insulin doses or vice versa. CGM metrics and profiles including glycemic variability (GV), time in range (TIR, 3.9-10.0 mmol/L), time below range (TBR, <3.9 mmol/L), time above range (TAR, >10.0 mmol/L), and postprandial glucose excursions, as well as incidence of hypoglycemia. RESULTS: Forty-six T2DM patients completed the study. There was no significant difference in parameters of daily GV and postprandial glucose excursions between the Equil patch insulin pump treatment and the Medtronic insulin pump treatment. Similarly, there was no between-treatment difference in TIR, TBR, and TAR, as well as the incidence of hypoglycemia. CONCLUSION: The Equil patch insulin pump was similar to the traditional MMT-712 insulin pump in terms of glycemic control. Equil patch insulin pump is a reliable tool for glycemic management of diabetes mellitus.


Subject(s)
Diabetes Mellitus, Type 2 , Hypoglycemia , Humans , Blood Glucose , Blood Glucose Self-Monitoring , Catheters , Continuous Glucose Monitoring , Diabetes Mellitus, Type 2/drug therapy , Glucose , Hypoglycemia/chemically induced , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Cross-Over Studies
2.
PeerJ ; 11: e15761, 2023.
Article in English | MEDLINE | ID: mdl-37489121

ABSTRACT

Background: Short-term (2 weeks to 3 months) insulin intensive therapy using continuous subcutaneous insulin infusion (CSII) can improve islet beta cell function and prolong glycemic remission in patients with newly diagnosed type 2 diabetes mellitus (T2DM). However, the total daily insulin dose (TDD, IU/kg/d) required to achieve near-normoglycemic control with CSII still needs to be frequently adjusted based on blood glucose monitoring. Although real-time continuous glucose monitoring (rtCGM), which measures the interstitial fluid glucose concentration continuously without much difficulty, facilitates the adjustment of insulin dosage, its adoption in the T2DM population is strictly limited by insurance coverage and lack of awareness of rtCGM among clinicians. Thus, it is of clinical significance to identify easy-to-use parameters that may allow a more rapid and accurate prediction of TDD requirement. This study aimed to explore the association between hand grip strength (HGS) and TDD requirement in patients with T2DM receiving CSII therapy. Methods: A total of 180 eligible patients with T2DM were enrolled in the study and divided into three groups based on their HGS: low (L), medium (M), and high (H). The TDD requirement was calculated on day 7 or 8 of CSII treatment. Anthropometric parameters, including HGS, skeletal muscle mass, skeletal muscle index (SMI) and 6-m gait speed, and laboratory data, were collected on the morning of the second day after admission, within the first 24 h of CSII therapy. These parameters were used to identify significant predictors of TDD requirement using Pearson or Spearman correlation test, and stepwise multiple regression analysis. Results: There were no significant differences in age, duration of T2DM, waist-to-hip ratio (WHR), body mass index (BMI), blood pressure, liver function, estimated glomerular filtration rate, triglyceride, total cholesterol, glycosylated hemoglobin A1c (HbA1c), homeostatic model assessment of insulin resistance (HOMA-IR), and homeostasis model assessment of beta cell function (HOMA-ß) among the groups. The H group had higher body muscle mass-to-fat ratio (BMFR), skeletal muscle mass-to-fat ratio (SMFR), SMI, 6-m gait speed, and lower TDD requirement than the M and L groups. The HGS negatively correlated with TDD requirement (r = -0.33, p < 0.001) after adjusting for sex, age, BMI, WHR, HbA1c, Ln (HOMA-ß), Ln (HOMA-IR), Ln (BMFR), Ln (SMFR), SMI, and 6-m gait speed. Multivariate stepwise regression analysis indicated that HGS was an independent predictor of TDD requirement in patients with T2DM (ß = -0.45, p < 0 001). Conclusion: Lower HGS is associated with an increased TDD requirement in T2DM patients. HGS may facilitate the prediction of TDD requirement in T2DM patients receiving CSII therapy.


Subject(s)
Diabetes Mellitus, Type 2 , Insulin , Humans , Insulin/therapeutic use , Diabetes Mellitus, Type 2/drug therapy , Hypoglycemic Agents/therapeutic use , Blood Glucose Self-Monitoring , Cross-Sectional Studies , Glycated Hemoglobin , Hand Strength , Blood Glucose/metabolism , Insulin, Regular, Human/therapeutic use
3.
Anaesthesist ; 70(10): 854-862, 2021 10.
Article in English | MEDLINE | ID: mdl-34003302

ABSTRACT

PURPOSE: Only few studies have analyzed the global distribution of anesthesia research. This study was designed to reveal the current global research status of anesthesiology. METHODS: Articles published between 1999 and 2018 in international journals in the field of anesthesiology were retrieved from the PubMed database. The top 20 ranked countries were identified. The gross domestic product (GDP) of each country was also retrieved to reveal the correlation between research outputs and the economy. The total outputs and outputs per 10 million inhabitants in each country were calculated and compared. To analyze the quality of publications among the top 10 ranked countries, the impact factor (IF), article influence score (AIS), and immediacy index (ImI) were calculated and analyzed. In addition, the keywords of publications were retrieved to conduct co-occurrence analysis in order to determine the research focus in anesthesiology. RESULTS: A total of 112,918 articles were published in 30 selected journals from 1999 to 2018. There was a positive correlation between research outputs and GDP of 10 countries (p < 0.001, r = 0.825). The USA ranked 1st with 21,703 articles, followed by the UK (8393 articles) and Germany (6504 articles). Canada had the highest number of publications per 10 million inhabitants in 2018. The UK had the highest average IF (4.70), average AIS (1.16), and average ImI (1.64) among the 10 countries. The research highlights in the field of anesthesiology included "mechanism and management of pain", "cardiac anesthesia", "pediatric anesthesia and airway management", "analgesia" and "anesthetic agents". CONCLUSION: Regarding quantity trend, the output of global production in anesthesiology increased continuously as the number of articles from the high-output countries showed an increasing trend; however, there was still a gap between developing and developed countries in research quality. High-quality research should be encouraged in developing countries.


Subject(s)
Anesthesia , Anesthesiology , Bibliometrics , Child , Germany , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...