Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Ophthalmol ; 15(8): 1273-1278, 2022.
Article in English | MEDLINE | ID: mdl-36017042

ABSTRACT

AIM: To investigate the surgical outcomes of patients with chronic angle-closure glaucoma (CACG) treated with phacoemulsification (phaco)/endocyclophotocoagulation (ECP) with and without endoscopic goniosynechialysis (E-GSL). METHODS: A retrospective, nonrandomized, comparative case series was conducted. Patients with CACG who underwent phaco in combination with either ECP alone (ECP group) or GSL with ECP (E-GSL group) from 2018 to 2019 were followed for 12mo and reviewed. Clinical features and outcomes were identified and analyzed. The ECP and E-GSL groups were matched in age and baseline intraocular pressure (IOP). Changes in IOP, mean of visual acuity (VA), peripheral anterior synechiae (PAS) formation, and the number of glaucoma medications was examined. RESULTS: The ECP group included 32 eyes of 27 patients, and the E-GSL group included 32 eyes of 26 patients. The preoperative baseline IOP was 22.18±6.48 mm Hg in the ECP group and 22.95±6.71 mm Hg in the E-GSL group (P=0.644). The mean IOP reduction was 26.2% in the ECP group and 41.6% in the E-GSL group at 12mo. The mean postoperative VA (logMAR units) at 12mo was 0.47 in the ECP group and 0.36 in the E-GSL group. The reduction in PAS formation and the number of glaucoma medications was also higher in the ECP group than E-GSL group at 12mo. CONCLUSION: The phaco/ECP and phaco/E-GSL groups both achieve a significant reduction in IOP without complications associated with traditional glaucoma filtration surgeries.

2.
Exp Biol Med (Maywood) ; 247(14): 1287-1297, 2022 07.
Article in English | MEDLINE | ID: mdl-35507096

ABSTRACT

Due to the lack of an assessment approach, the image of in vivo nasal ciliary motion of allergic rhinitis (AR) has never been captured and analyzed to date. Here, we have used an optimized approach to analyze the nasal ciliary function in vivo in AR rats. The digital microscopy system, a method for direct observation of ciliary motion in a living AR rat model, was applied to visualize and measure ciliary motion in vivo, including ciliary beat frequency (CBF) and ciliary beat distance (CBD). The AR rat model was established by ovalbumin sensitization. Comparisons of nasal ciliary motion in vivo between the experimental group (ovalbumin sensitization, allergen, or histamine) and the control group were analyzed. In the living rat model of allergic rhinitis, CBF and CBD decreased to 57.8 and 73.1% of the control group, respectively, but were restored after administration of chlorpheniramine maleate. Ovalbumin (OVA) significantly inhibited the ciliary motion of normal mucosa in vivo. However, responding to the OVA challenge, the ciliary motion of OVA-sensitized mucosa would not decrease further and stay at a stable level. Histamine stimulated in vivo ciliary motion quickly within 30 min, but afterward, the ciliary motion gradually decreased below the baseline. These results have clarified that in vivo ciliary motion was impaired by nasal mucosal sensitization, and this impairment was most likely related to allergen challenge and histamine. In addition, the short-term stimulation and long-term inhibition effects of histamine on in vivo ciliary motion were first reported in this study.


Subject(s)
Histamine , Rhinitis, Allergic , Allergens , Animals , Cytokines , Disease Models, Animal , Histamine/pharmacology , Mice , Mice, Inbred BALB C , Nasal Mucosa , Ovalbumin/pharmacology , Rats
3.
ACS Biomater Sci Eng ; 8(5): 2016-2027, 2022 05 09.
Article in English | MEDLINE | ID: mdl-35412808

ABSTRACT

In the last few years, the use of tissue adhesives in corneal perforation has gained immense popularity in clinical practices. The present study aimed to devise a new application of urocanic-acid-modified chitosan (CS) with methylene blue (MB) as a photosensitizer for the development of a photo-crosslinked tissue adhesive. In particular, the curing time was controlled with the aid of a 650 nm red diode. Under the same irradiation condition, the mechanical properties were tuned using the photosensitizer at different concentrations. In vitro tests revealed that the gel was ductile and biocompatible. The application of the gel to a perforated cornea model stopped the leakage of aqueous humor, immediately after the gel was photo-crosslinked. The blue appearance of the gel provided high precision when applied to corneal wounds. Importantly, the crosslinked gel became transparent within 24 h, owing to the dissipation of MB from tears, and the gel spontaneously sloughed off without artificial removal. Altogether, the study reported the development of a novel photo-crosslinkable urocanic-acid-modified CS gel that exhibited significant potential to be utilized in the healing of corneal perforation.


Subject(s)
Chitosan , Corneal Perforation , Urocanic Acid , Humans , Hydrogels , Photosensitizing Agents
4.
Acta Otolaryngol ; 137(10): 1077-1082, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28641038

ABSTRACT

OBJECTIVES: To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. METHODS: Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. RESULTS: With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p < .001). CONCLUSION: The study suggests six-month CI activation can be effective for suppressing tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss/therapy , Speech Perception/physiology , Tinnitus/prevention & control , Adolescent , Adult , Aged , Auditory Threshold , Cohort Studies , Female , Hearing Loss/complications , Hearing Loss/physiopathology , Humans , Male , Middle Aged , Tinnitus/complications , Tinnitus/diagnosis , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...