Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Echocardiography ; 31(5): 669-73, 2014 May.
Article in English | MEDLINE | ID: mdl-24698513

ABSTRACT

A 2.5-year-old boy presented with frequent hospitalizations due to recurrent respiratory tract infections with dyspnea. A fibromuscular membrane dividing the left atrium with obstruction of left atrial inflow to the left ventricle was documented by two-dimensional transthoracic echocardiography (2DTTE). Live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over 2DTTE by providing en face views of the 2 obstructing orifices in the membrane enabling accurate assessment of their position, shape and size. 3DTTE also showed clearly the location of the membrane superior and proximal to the left atrial appendage which was not well delineated by 2DTTE. In addition, 3DTTE demonstrated the full extent of the left atrial appendage and careful sequential cropping of the 3D dataset showed it to have 2 distinct lobes and no thrombus. These findings provided comprehensive assessment of the lesion and were helpful in surgical decision making and planning.


Subject(s)
Atrial Appendage/diagnostic imaging , Atrial Function, Left/physiology , Cor Triatriatum/diagnostic imaging , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Atrial Appendage/physiopathology , Child, Preschool , Cor Triatriatum/physiopathology , Diagnosis, Differential , Humans , Male
2.
Echocardiography ; 23(9): 763-70, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16999695

ABSTRACT

BACKGROUND: Transcatheter Amplatzer septal occluder (ASO) device closure of atrial septal defects (ASDs) has traditionally been guided by two-dimensional transesophageal echocardiography (2D-TEE) and intracardiac echocardiography (ICE) modalities. Real time three-dimensional transthoracic echocardiography (RT3D-TTE) provides rotating images to define ASD and adjacent structures with potential as an alternative to 2D-TEE or ICE for guiding the device closure of ASD. Our aim was to assess the feasibility and effectiveness of RT3D-TTE in parasternal four-chamber views to guide ASO device closure of ASD. METHODS AND RESULTS: From July 2004 to August 2005, 59 patients underwent transcatheter ASO device closure of ASD. The first 30 patients underwent 2D-TEE guidance under general anesthesia and the remaining 29 patients underwent RT3D-TTE guidance with local anesthesia. All interventions were successfully completed without complications. The clinical characteristics and transcatheter closure variables of RT3D-TTE and 2D-TEE were compared. Echocardiographic visualization of ASD and ASO deployment was found to be adequate when using either methods. Catheterization laboratory time (39.1 +/- 5.4 vs 78.8 +/- 14.1 minutes, P < 0.001) and interventional procedure length (7.6 +/- 4.2 vs 15.3 +/- 2.9 minutes, P < 0.001) were shortened by using RT3D-TTE as compared with 2DE-TEE. There was no difference in the rate of closure following either method, assessed after a 6-month follow-up. The maximal diameter measured by RT3D-TTE and 2D-TEE was correlated well with a balloon-stretched ASD size (y = 0.985x + 0.628, r = 0.924 vs y = 0.93x + 2.08, r = 0.885, respectively). CONCLUSION: RT3D-TTE may be a feasible, safe, and effective alternative to the standard practice of using 2D-TEE to guide ASO deployment.


Subject(s)
Balloon Occlusion/instrumentation , Cardiac Catheterization , Computer Systems , Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Adolescent , Child , Child, Preschool , Feasibility Studies , Female , Follow-Up Studies , Humans , Length of Stay , Male , Observer Variation , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Prosthesis Design , Research Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...