Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Mater Eng ; 16(5): 309-18, 2006.
Article in English | MEDLINE | ID: mdl-17075166

ABSTRACT

Lower-limb prostheses are used to restore amputee's walking. Monolimb is one of the designs referring to socket and the shank being molded into one piece of thermoplastic material. Appropriate shank flexibility of a monolimb can improve gait of an amputee. However, during the fabrication, the variations of design variables are inevitably produced which may lead the unexpected shank deflection and directly influence on gait efficiency of an amputee. This paper presents a robust design procedure for improvement of quality of the monolimb by simultaneously minimizing performance variations caused by variations in design variables and bringing the mean value of performance on target. The robust design procedure embodies the integration of response surface methodology with genetic algorithms. Response surface models are developed for the responses of monolimb as functions of design variables over the region of interest and genetic algorithms are employed to find the robust solution. A robust design of monolimb is performed for an amputee subject and the results show that the robust design can design a "robust" monolimb which provides specified performance targets that are minimally sensitive to the variations of design variables. This indicates that robust design may have the potential application in improving the quality of the prescribed prosthesis.


Subject(s)
Amputees/rehabilitation , Artificial Limbs , Computer-Aided Design , Knee Joint/physiopathology , Lower Extremity/physiopathology , Models, Biological , Tibia/physiopathology , Algorithms , Computer Simulation , Equipment Design/methods , Equipment Failure Analysis , Humans , Weight-Bearing
2.
Med Eng Phys ; 28(3): 290-6, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16112888

ABSTRACT

Monolimb refers to a transtibial prosthesis with the prosthetic socket and the shank being molded into one piece of thermoplastic material. Shank flexibility of a monolimb can improve gait and comfort. However, fatigue failure of monolimbs under cyclic walking load is an important concern. This study is to evaluate the fatigue life of a monolimb designed for a transtibial amputee, based on finite element analysis, the statistical Miner's rule and reliability analysis. Stress uncertainty due to modeling error and the scatter in fatigue test data were considered. Results indicated that the accuracy of fatigue life evaluation of monolimb depends significantly on the precision of stress estimation. In addition, relationship between fatigue failure probability and the number of walking steps was suggested providing a reference for clinicians to determine the interval of the inspection for the monolimb.


Subject(s)
Artificial Limbs , Equipment Failure Analysis/methods , Knee Joint/physiopathology , Knee Prosthesis , Models, Biological , Prosthesis Failure , Amputees/rehabilitation , Computer Simulation , Finite Element Analysis , Humans , Numerical Analysis, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...