Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Magn Reson ; 357: 107588, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37976810

ABSTRACT

We demonstrate the construction of 7 Tesla and 12 Tesla all high-temperature-superconducting (HTS) magnets, small enough to fit on your wrist. The size of the magnet reduces the cost of fabrication, decreases the fringe field to permit facile siting of magnets, and decreases the stored energy of high field magnets. These small HTS-based magnets are being developed for gyrotron microwave sources for use in high-field nuclear magnetic resonance applications. The 7 Tesla and 12 Tesla magnets employ a no-insulation winding technique and are cooled to 4.2 Kelvin in a liquid helium cryostat. The 7 Tesla magnet is a single pancake coil, made of only 9.4 m of HTS tape, with an inner diameter of 8 mm and an outer diameter of 24 mm. This magnet was charged up to 1168 Amperes, generating a field of 7.3 Tesla. The 12 Tesla magnet is comprised of two pancake coils (inner diameter of 10 mm and outer diameter of 27 mm) connected in series. This magnet reached its maximum field at a current of 850 Amperes.

2.
J Magn Reson ; 343: 107305, 2022 10.
Article in English | MEDLINE | ID: mdl-36191440

ABSTRACT

Spherical rotors in magic angle spinning (MAS) nuclear magnetic resonance (NMR) experiments have potential advantages relative to cylindrical rotors in terms of ease of fabrication, low risk of rotor crash, easy sample exchange, and better microwave access. However, one major disadvantage so far of spherical rotors is poor NMR filling factor due to the small sample volume and large cylindrical radiofrequency (RF) coil. Here we present a novel NMR coil geometry in the form of a spherical coil. The spherical coil best fits the spherical sample to maximize sensitivity, while also providing excellent RF homogeneity. We further improve NMR sensitivity by employing a spherical shell as the rotor, thereby maximizing sample volume (219 µL in this case of 9.5 mm outer diameter spheres). The spinning gas is supplied by a 3D-printed ring stator external to the coil, thereby introducing a simplified form of MAS stators. In this apparatus, the RF field generated along the coil axis is perpendicular to the external magnetic field, regardless of rotor orientation. We observe a linear increase in sensitivity with increasing sample volume. We also simulate the RF performance of spherical and cylindrical solenoid coils with constant or variable pitch for spherical and cylindrical rotors, respectively. The simulation results show that spherical solenoid coils generate comparable B1 field intensities but have better homogeneity than cylindrical solenoid coils do.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Magnetic Resonance Spectroscopy/methods , Microwaves , Computer Simulation
3.
J Magn Reson ; 308: 106518, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31345770

ABSTRACT

Continuous wave dynamic nuclear polarization (DNP) increases the sensitivity of NMR, yet intense microwave fields are required to transition magic angle spinning (MAS) DNP to the time domain. Here we describe and analyze Teflon lenses for cylindrical and spherical MAS rotors that focus microwave power and increase the electron Rabi frequency, ν1s. Using a commercial simulation package, we solve the Maxwell equations and determine the propagation and focusing of millimeter waves (198 GHz). We then calculate the microwave intensity in a time-independent fashion to compute the ν1s. With a nominal microwave power input of 5 W, the average ν1s is 0.38 MHz within a 22 µL sample volume in a 3.2 mm outer diameter (OD) cylindrical rotor without a Teflon lens. Decreasing the sample volume to 3 µL and focusing the microwave beam with a Teflon lens increases the ν1s to 1.5 MHz. Microwave polarization and intensity perturbations associated with diffraction through the radiofrequency coil, losses from penetration through the rotor wall, and mechanical limitations of the separation between the lens and sample are significant challenges to improving microwave coupling in MAS DNP instrumentation. To overcome these issues, we introduce a novel focusing strategy using dielectric microwave lenses installed within spinning rotors. One such 9.5 mm OD cylindrical rotor assembly implements a Teflon focusing lens to increase the ν1s to 2.7 MHz within a 2 µL sample. Further, to access high spinning frequencies while also increasing ν1s, we analyze microwave coupling into MAS spheres. For 9.5 mm OD spherical rotors, we compute a ν1s of 0.36 MHz within a sample volume of 161 µL, and 2.5 MHz within a 3 µL sample placed at the focal point of a novel double lens insert. We conclude with an analysis and discussion of sub-millimeter diamond spherical rotors for time domain DNP at spinning frequencies >100 kHz. Sub-millimeter spherical rotors better overlap a tightly focused microwave beam, resulting in a ν1s of 2.2 MHz. Lastly, we propose that sub-millimeter dielectric spherical microwave resonators will provide a means to substantially improve electron spin control in the future.

4.
J Magn Reson ; 303: 1-6, 2019 06.
Article in English | MEDLINE | ID: mdl-30978570

ABSTRACT

Spherical rotors in magic angle spinning (MAS) experiments have significant advantages over traditional cylindrical rotors including simplified spinning implementation, easy sample exchange, more efficient microwave coupling for dynamic nuclear polarization (DNP), and feasibility of downscaling to access higher spinning frequencies. Here, we implement spherical rotors with 4 mm outside diameter (o.d.) and demonstrate spinning >28 kHz using a single aperture for spinning gas. We show a modified stator geometry to improve fiber optic detection, increase NMR filling factor, and improve alignment for sample exchange and microwave irradiation. Higher NMR Rabi frequencies were obtained using smaller radiofrequency (RF) coils on small-diameter spherical rotors, compared to our previous implementation of MAS spheres with an o.d. of 9.5 mm. We report nutation fields of 110 kHz on 13C with 820 W of input power and 100 kHz on 1H with 800 W of input power. Proton decoupling fields of 78 kHz were applied over 20 ms of signal acquisition without any sign of arcing. Compared to our initial demonstration of a split coil for 9.5 mm spheres, this current implementation of a double-saddle coil inductor for 4 mm spheres not only intensifies the RF fields, but also improves RF homogeneity. We achieve an 810°/90° nutation intensity ratio of 0.84 at 300.197 MHz (1H). We also show electromagnetic simulations predicting a nearly 3-fold improvement in electron Rabi frequency of 0.99 MHz (with 4 mm spheres) compared to 0.38 MHz (with 3.2 mm cylinders), with 5 W of incident microwave power. Further improvements in magnetic resonance spin control are expected as RF inductors and microwave coupling are optimized for spherical rotors and scaled down to the micron scale.


Subject(s)
Magnetic Resonance Spectroscopy/instrumentation , Algorithms , Computer Simulation , Electromagnetic Fields , Equipment Design , Fiber Optic Technology , Gases/chemistry , Microwaves , Radio Waves
5.
Respir Physiol Neurobiol ; 186(3): 296-302, 2013 May 01.
Article in English | MEDLINE | ID: mdl-23499567

ABSTRACT

This study examines the effects of inspiratory muscle warm-up (IMW) on performance and muscle oxygenation during cycling exercise. In a randomized crossover study of 10 female soccer players, the IMW, placebo (IMWP) and control (CON) trials were conducted before two 6-min submaximal cycling exercises (100 and 150W) followed by intermittent high-intensity sprint (IHIS, 6×10s with 60s recovery). The reduction in tissue saturation index (TSI) in legs in the IMW were significantly less than those in IMWP and CON (P<0.01) during submaximal cycling exercises. The average reduction in TSI during the IHIS test with IMW was significantly less than those in the IMWP and CON (P=0.023). Nevertheless, the IHIS performance with IMW did not differ from that in other trials. In conclusion, the leg TSI during continuous submaximal cycling exercise followed by intermittent sprinting was likely improved by specific IMW (40% maximal inspiratory mouth pressure), which did not enhance IHIS performance.


Subject(s)
Athletes , Bicycling/physiology , Hemoglobins/metabolism , Oxygen Consumption/physiology , Respiratory Muscles/physiology , Adolescent , Ammonia/blood , Athletic Performance , Cross-Over Studies , Female , Humans , Lactic Acid/blood , Oxyhemoglobins/metabolism , Physical Endurance , Pulmonary Gas Exchange/physiology , Single-Blind Method , Spectroscopy, Near-Infrared , Statistics, Nonparametric , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...