Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Publication year range
1.
ACS Nano ; 11(9): 8790-8795, 2017 09 26.
Article in English | MEDLINE | ID: mdl-28800221

ABSTRACT

Pressure sensors should have an excellent sensitivity in the range of 0-20 kPa when applied in wearable applications. Traditional pressure sensors cannot achieve both a high sensitivity and a large working range simultaneously, which results in their limited applications in wearable fields. There is an urgent need to develop a pressure sensor to make a breakthrough in both sensitivity and working range. In this paper, a graphene-paper pressure sensor that shows excellent performance in the range of 0-20 kPa is proposed. Compared to most reported graphene pressure sensors, this work realizes the optimization of sensitivity and working range, which is especially suitable for wearable applications. We also demonstrate that the pressure sensor can be applied in pulse detection, respiratory detection, voice recognition, as well as various intense motion detections. This graphene-paper pressure sensor will have great potentials for smart wearable devices to achieve health monitoring and motion detection.


Subject(s)
Biosensing Techniques/instrumentation , Graphite/chemistry , Paper , Pressure , Wearable Electronic Devices , Equipment Design , Humans , Motion , Movement , Nanostructures/chemistry , Nanostructures/ultrastructure
2.
Front Plant Sci ; 8: 980, 2017.
Article in English | MEDLINE | ID: mdl-28642779

ABSTRACT

In the North China Plain, groundwater tables have been dropping at unsustainable rates of 1 m per year due to irrigation of a double cropping system of winter wheat and summer maize. To reverse the trend, we examined whether alternative crop rotations could save water. Moisture contents were measured weekly at 20 cm intervals in the top 180 cm of soil as part of a 12-year field experiment with four crop rotations: sweet potato→ cotton→ sweet potato→ winter wheat-summer maize (SpCSpWS, 4-year cycle); peanuts → winter wheat-summer maize (PWS, 2-year cycle); ryegrass-cotton→ peanuts→ winter wheat-summer maize (RCPWS, 3-year cycle); and winter wheat-summer maize (WS, each year). We found that, compared to WS, the SpCSpWS annual evapotranspiration was 28% lower, PWS was 19% lower and RCPWS was 14% lower. The yield per unit of water evaporated improved for wheat within any alternative rotation compared to WS, increasing up to 19%. Average soil moisture contents at the sowing date of wheat in the SpCSpWS, PWS, and RCPWS rotations were 7, 4, and 10% higher than WS, respectively. The advantage of alternative rotations was that a deep rooted crop of winter wheat reaching down to 180 cm followed shallow rooted crops (sweet potato and peanut drawing soil moisture from 0 to 120 cm). They benefited from the sequencing and vertical complementarity of soil moisture extraction. Thus, replacing the traditional crop rotation with cropping system that involves rotating with annual shallow rooted crops is promising for reducing groundwater depletion in the North China Plain.

3.
Nanoscale ; 9(24): 8266-8273, 2017 Jun 22.
Article in English | MEDLINE | ID: mdl-28585963

ABSTRACT

Conventional strain sensors rarely have both a high gauge factor and a large strain range simultaneously, so they can only be used in specific situations where only a high sensitivity or a large strain range is required. However, for detecting human motions that include both subtle and large motions, these strain sensors can't meet the diverse demands simultaneously. Here, we come up with laser patterned graphene strain sensors with self-adapted and tunable performance for the first time. A series of strain sensors with either an ultrahigh gauge factor or a preferable strain range can be fabricated simultaneously via one-step laser patterning, and are suitable for detecting all human motions. The strain sensors have a GF of up to 457 with a strain range of 35%, or have a strain range of up to 100% with a GF of 268. Most importantly, the performance of the strain sensors can be easily tuned by adjusting the patterns of the graphene, so that the sensors can meet diverse demands in both subtle and large motion situations. The graphene strain sensors show significant potential in applications such as wearable electronics, health monitoring and intelligent robots. Furthermore, the facile, fast and low-cost fabrication method will make them possible and practical to be used for commercial applications in the future.


Subject(s)
Actigraphy/instrumentation , Graphite , Movement , Equipment Design , Humans , Wearable Electronic Devices
4.
Nat Commun ; 8: 14579, 2017 02 24.
Article in English | MEDLINE | ID: mdl-28232739

ABSTRACT

Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas.


Subject(s)
Artificial Intelligence , Artificial Organs , Pharynx/physiopathology , Speech Disorders/therapy , Wearable Electronic Devices , Equipment Design , Graphite/chemistry , Humans , Lasers, Semiconductor , Sound , Sound Spectrography , Speech Disorders/physiopathology
5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(2): 520-6, 2016 Feb.
Article in Chinese | MEDLINE | ID: mdl-27209761

ABSTRACT

This paper discussed the response of spectral characteristics on high temperature at grain filling stage of different spring maize varieties by adopting two spectrometer (SPAD-502 Chlorophyll Meter and Sunscan Plant Canopy Analyzer), and analyzed the impact of high temperature on the photosynthetic properties of spring maize in North China Plain. The test was conductedfrom the year 2011 to 2012 in Wuqiao County, Hebei Province. This test chose three different varieties, i. e. Tianyu 198 (TY198), Xingyu 998 (XY998) and Tianrun 606 (TR606), then two sowing date (April 15th and April 25th) was set. We analyzed chlorophyll relative content (SPAD), leaf area index (LAI) and photosynthetically active radiation (PAR) at grain filling stage. The results showed that the days of daily maximum temperature above 33 °C and the mean day temperature at grain filling stage in spring maize sowing on April 15th increased 3.5 d and 0.8 °C, respectively, compared to that sowing on April 25th, moreover the sunshine hours, rainfall, diurnal temperature and length of growing period were similar. Compared with XY998 and TR606, TY198's stress tolerance indices (STI) increased by 2.9% and 11.0%, respectively. According to STI from high to low order, TY198, XY998 and TR606 respectively as heat resistant type, moderate heat resistant type and thermo-labile type variety. TY198, compared with XY998 and TR606 sowing on April 15th, yield increased by 4.1% and 13.7%, SPAD increased by 12.5% and 19.6%, LAI increased by 5.3% and 5.6%, PAR increased by 4.0% and 14.0%. Sowing on April 15th, yield increased by 1.3% and 2.8%, SPAD increased by 3.5% and 6.0%, LAI increased by 1.7% and 4.1%, PAR increased by -4.4% and 0.9%. Three varieties had significant yield differences in the environment of high temperature stress, heat resistant type have significant (p < 0.05) advantage in the aspect of yield, SPAD and LAI. The production of TY198, XY998 and TR606 sowing on April 15th compared to that sowing on April 25th decreased by 3.2%, 5.9% and 12.6%, and SPAD decreased by 8.6%, 12.4% and 15.7%, LAI decreased by 11.7%, 17.6% and 19.8%, PAR decreased by 3.4%, 11.3% and 14.5%; STI had a significant negatively correlated with SPAD fall range (r = -0.883, p < 0.05) and LAI fall range (r = -0.853, P < 0.05), and highly significantly negatively correlated with PAR fall range (r = -0.923, p < 0.01); while SPAD fall range and PAR fall range showed a significant positive correlation (r = 0.872, p < 0.05); LAI fall range and PAR fall range were significantly positive correlation (r = 0.943, p < 0.05). In conclusion, heat tolerant type varieties of spring maize under high temperature stress at gain filling stage could maintain a relatively high content of chlorophyll at the individual level, a relatively high leaf area at the group level, and then keep a higher luminous energy interception and utilization, and weakened inhibition magnitude of high temperature on photosynthetic capacity, reduced the yield fall range, then achieved high and stable yield. The heat tolerance in varieties could be one of the main indicators for identification and evaluation the response to high temperature by spectral characteristics (SPAD, LAI and PAR). Thus it provides a basis by using spectral characteristics to study heat tolerance on maize.


Subject(s)
Hot Temperature , Spectrum Analysis , Zea mays/physiology , China , Chlorophyll/analysis , Edible Grain , Photosynthesis , Plant Leaves , Stress, Physiological , Sunlight
6.
Nanoscale ; 8(10): 5516-25, 2016 Mar 14.
Article in English | MEDLINE | ID: mdl-26787399

ABSTRACT

A point Electrical Thermal Acoustic (ETA) device based on aluminum nanowire contacts is designed and fabricated. Interdigitated structural aluminum nanowires are released from the substrate by Inductively Coupled Plasma Reactive Ion Etching (ICP-RIE). By releasing the interdigitated structure, the nanowires contact each other at approximately 1 mm above the wafer, forming a Point Contact Structure (PCS). It is found that the PCS acoustic device realizes high efficiency when a biased AC signal is applied. The PCS acoustic device reaches a sound pressure level as high as 67 dB at a distance of 1 cm with 74 mW AC input. The power spectrum is flat, ranging from 2 kHz to 20 kHz with a less than ±3 dB fluctuation. The highest normalized Sound Pressure Level (SPL) of the point contact structure acoustic device is 18 dB higher than the suspended aluminum wire acoustic device. Comparisons between the PCS acoustic device and the Suspended Aluminum Nanowire (SAN) acoustic device illustrate that the PCS acoustic device has a flatter power spectrum within the 20 kHz range, and enhances the SPL at a lower frequency. Enhancing the response at lower frequencies is extremely useful, which may enable earphone and loudspeaker applications within the frequency range of the human ear with the help of pulse density modulation.

7.
Sensors (Basel) ; 15(2): 2538-47, 2015 Jan 23.
Article in English | MEDLINE | ID: mdl-25625905

ABSTRACT

This paper proposes a novel flexible piezoelectric micro-machined ultrasound transducer, which is based on PZT and a polyimide substrate. The transducer is made on the polyimide substrate and packaged with medical polydimethylsiloxane. Instead of etching the PZT ceramic, this paper proposes a method of putting diced PZT blocks into holes on the polyimide which are pre-etched. The device works in d31 mode and the electromechanical coupling factor is 22.25%. Its flexibility, good conformal contacting with skin surfaces and proper resonant frequency make the device suitable for heart imaging. The flexible packaging ultrasound transducer also has a good waterproof performance after hundreds of ultrasonic electric tests in water. It is a promising ultrasound transducer and will be an effective supplementary ultrasound imaging method in the practical applications.


Subject(s)
Diagnostic Imaging , Heart/diagnostic imaging , Phantoms, Imaging , Ceramics , Dimethylpolysiloxanes/chemistry , Equipment Design , Humans , Radiography , Transducers , Ultrasonics
8.
Ying Yong Sheng Tai Xue Bao ; 23(1): 178-84, 2012 Jan.
Article in Chinese | MEDLINE | ID: mdl-22489497

ABSTRACT

Raising duck in paddy rice field is an evolution of Chinese traditional agriculture. In May-October 2010, a field experiment was conducted in a double cropping rice region of Hunan Province, South-central China to study the nitrogen (N) cycling in rice-duck mutual ecosystem during early rice and late rice growth periods, taking a conventional paddy rice field as the control. Input-output analysis method was adopted. The N output in the early rice-duck mutual ecosystem was 239.5 kg x hm(-2), in which, 12.77 kg x hm(-2) were from ducks, and the N output in the late rice-duck mutual ecosystem was 338.7 kg x hm(-2), in which, 23.35 kg x hm(-2) were from ducks. At the present N input level, there existed soil N deficit during the growth seasons of both early rice and late rice. The N input from duck sub-system was mainly from the feed N, and the cycling rate of the duck feces N recycled within the system was 2.5% during early rice growth season and 3.5% during late rice growth season. After late rice harvested, the soil N sequestration was 178.6 kg x hm(-2).


Subject(s)
Agriculture/methods , Ducks/growth & development , Ecosystem , Nitrogen Cycle/physiology , Oryza/growth & development , Animals , Nitrogen/analysis , Seasons , Soil/analysis
9.
Huan Jing Ke Xue ; 31(11): 2795-803, 2010 Nov.
Article in Chinese | MEDLINE | ID: mdl-21250468

ABSTRACT

For the point of view that recycling economy system is one of ways to achieve the low-carbon economy, we have made an evaluation on a typical circular agriculture duck industry in Hunan Province, China, through improving the framework of life cycle assessment (LCA). The analysis indicated that the consumption of non-renewable resources, land and water were 48.629 MJ, 2.36 m2 and 1 321.41 kg, while the potential greenhouse gas (GHGs), acidification, eutrophication, human toxicity, freshwater ecotoxicity and terrestrial ecotoxicity were 11 543.26 g (CO2 eq), 52.36g (SO2eq), 25.83g (PO4eq), 1.26, 60.74 and 24.65 g (1,4-DCBeq), respectively. The potential damage of aquatic eutrophication, freshwater ecotoxicity and terrestrial ecotoxicity was more serious than that of GHGs. Main results were following: i. the circular agricultural chain promoted the principle of "moderate circulation", which based on the traditional production methods; ii. circular agriculture could not blindly pursue low carbon development. Instead, soil and biological carbon sequestration should be considered, in addition to reducing carbon emissions; iii. circular economy and circular agriculture should take other potential environmental impacts into account such as acidification, eutrophication and ecotoxicity,with the exception to carbon emissions,to developed integrated system assessment; iv. LCA could provide a comprehensive assessment of circular agriculture, and it was worth of further study.


Subject(s)
Agriculture , Air Pollution/prevention & control , Carbon Dioxide/analysis , Economics , Environmental Pollution/prevention & control , Animals , China , Conservation of Natural Resources , Ducks/growth & development , Greenhouse Effect , Humans , Life Cycle Stages
SELECTION OF CITATIONS
SEARCH DETAIL
...