Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Heart Rhythm ; 20(12): 1682-1688, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37689174

ABSTRACT

BACKGROUND: Although studies have shown that an increased resting heart rate measured randomly at a single point of the day has been associated with adverse cardiovascular outcomes, the utility of continuous monitoring of nighttime heart rate (NTHR) has remained largely uninvestigated. OBJECTIVE: This study aimed to explore the association between NTHR and cardiovascular mortality. METHODS: The Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-implanted Patients, which is a prospective cohort study, enrolled patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator between 2010 and 2015. Baseline NTHR was measured during the programmed sleep period from 30 to 60 days after implantation. The primary outcome was cardiovascular mortality, fitted by a restricted cubic spline function. RESULTS: A total of 534 implantable cardioverter-defibrillator recipients with sinus rhythm during the detection window were included in the study. The mean baseline NTHR was 59.6 ± 8.0 beats/min. During the follow-up period of 60.4 ± 21.8 months, 88 (16.5%) patients experienced cardiovascular mortality. After considering potential confounders, a linear association was observed. Each 1 beat/min increase in NTHR was associated with a 7.8%, 10.1%, and 5.7% increase in the risk of cardiovascular mortality in the total population, patients with heart failure, and patients without heart failure, respectively. CONCLUSION: Continuous monitoring of NTHR may identify patients at high risk of cardiovascular mortality in a timely manner, with the potential for "preemptive" action. TRIAL REGISTRATION: No. ChiCTR-ONRC-13003695.


Subject(s)
Defibrillators, Implantable , Heart Failure , Humans , Cohort Studies , Heart Rate , Prospective Studies , Arrhythmias, Cardiac , Tachycardia , Treatment Outcome
2.
Am J Cardiol ; 204: 96-103, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37541154

ABSTRACT

Atrial high-rate episodes (AHREs) are prevalent in approximately 1/3 of patients with cardiac implanted electronic devices and are associated with an increased risk of several adverse outcomes. This study aimed to explore the factors associated with AHRE progression and the risk of all-cause mortality. At least 1 day with AHRE burden ≥15 minutes was identified in 124 of 343 recipients (36.2%) of an implantable cardioverter defibrillator or cardiac resynchronization therapy device. We included patients whose AHRE burden at the time of first detection was ≥15 minutes but <24 hours (n = 107). Various cut-off values (15 minutes, 6 hours, and 24 hours) of daily AHRE burden were analyzed. During an average follow-up of 4.2 years, 60 patients (56.1%) experienced ≥1 progression to greater AHRE burden. Patients with hypertension or greater AHRE burden at first detection were associated with faster progression. In addition, 27 deaths (45%) occurred among 60 patients with AHRE progression, compared with 25.5% (12 of 47) for those without progression. After multivariable adjustment, AHRE progression was independently associated with all-cause mortality (hazard ratio 2.56, 95% confidence interval 1.23 to 5.35, p = 0.012). Notably, AHRE progression within 1 month after their first detection was associated with an increased risk for all-cause mortality (hazard ratio 4.01, 95% confidence interval 1.76 to 9.16, p = 0.001) compared with patients without progression. However, a similar risk was not observed among patients with AHRE progression occurring after 1 month after their first detection. In conclusion, >1/2 of the patients with AHRE progressed to a greater burden over time. Continuous monitoring of the AHRE burden may help identify patients at great risk for death.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Humans , Risk Assessment , Heart Atria/diagnostic imaging , Defibrillators, Implantable/adverse effects , Cardiac Resynchronization Therapy Devices/adverse effects , Risk Factors
3.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37337705

ABSTRACT

AIMS: Left bundle branch pacing (LBBP) maintains left ventricular synchrony but induces right ventricular conduction delay (RVCD). Although anodal-ring capture (ARC) during bipolar LBBP improves RVCD, it is not achieved in all patients receiving LBBP. This study aimed to analyze the factors influencing ARC implementation. METHODS AND RESULTS: Patients receiving LBBP with intraoperative ARC testing were enrolled. Electrocardiographic parameters were measured, including stimulus-to-QRS duration (stim-QRSd), stimulus-to-left/right ventricular activation time (stim-LVAT/RVAT), and V6-V1 interpeak interval. The distribution of lead-tip sites was described as the corrected longitudinal and lateral distance (longit-/lat-dist). Relative angles of the LBBP lead were measured. Echocardiography in short-axis view was used to measure the intraseptal lead length. Intergroup comparisons, correlation analysis, and stepwise logistic regression were performed. In total, 105 patients were included, among which 65 (62%) patients achieved ARC at a pacing output ≤ 5.0 V/0.5 ms (average 3.1 V/0.5 ms). Anodal-ring capture further shortened the stim-QRSd by 13.1 ± 7.5 ms. Better unipolar-ring (cathodal) threshold and R-wave sensing in LBBP-ARC group indicated the critical role of ring-septum contact in ARC. Longer corrected longit-dist and shorter corrected lat-dist of lead-tip sites were positively correlated with higher success likelihood of ARC, likely due to the greater relative angle in which the lead enters the septum and consequently the longer intraseptal lead length and better ring-septum contact. CONCLUSION: This study elucidated the factors affecting the success likelihood of LBBP-ARC. These findings improve the understanding of LBBP-ARC, providing references for future research and clinical practice.


Subject(s)
Bundle of His , Pacemaker, Artificial , Humans , Cardiac Pacing, Artificial/methods , Heart Conduction System , Electrocardiography/methods
5.
Front Physiol ; 14: 1090038, 2023.
Article in English | MEDLINE | ID: mdl-36818447

ABSTRACT

Introduction: Autonomic nervous system (ANS) function quantified by heart rate variability (HRV) was associated with long-term prognosis, but it was rarely used in the evaluation of patients with heart failure, especially those with cardiac resynchronization therapy-defibrillator (CRT-D) implantation. This study aimed to describe the changes in ANS function among patients who underwent CRT-D with remote home monitoring function, and explore predictive value of HRV for ventricular tachyarrhythmias (VTAs) and all-cause mortality. Method: Patients who underwent CRT-D implantation were included. Device-measured all-day HR, night-time HR, and HRV (measured by the standard deviation of the atrial-atrial sensed intervals) were used to quantify ANS function. Multivariate Cox proportional hazards models were fitted to calculate hazard ratios (HRs) and 95% confidence intervals (CIs) of VTAs or all-cause mortality in relation to ANS function at baseline and 6 months post-implantation. The cutoff value was determined using restrictive cubic splines. Multivariable logistic regression was further established to determine factors influencing postoperative HRV. Results: A total of 170 patients treated with CRT-D were eligible for analysis. During a median follow-up period of 50.8 months, 61 patients died and 69 patients experienced at least one spontaneous episode of VTAs. At 6 months after CRT implantation, 114 patients showed improvement in HRV, increasing from 66.4 ± 19.4 ms to 76.7 ± 21.2 ms. The postoperative HRV was associated with both all-cause mortality (HRs: 0.983; 95% CI: 0.968 to 0.998, p = 0.012) and VTAs (HRs: 0.973; 95% CI: 0.954 to 0.993, p = 0.008), and the relative risk would significantly increase when the postoperative HRV lower than 75 ms. After adjusting for basic ANS function and possible influencing factors, patients without diabetes (p = 0.018) and with higher daily physical activity (p = 0.041) could maintain higher postoperative HRV after CRT implantation. Conclusion: More than two-thirds of heart failure patients showed improvement in ANS function following CRT treatment. However, patients with diabetes and low daily physical activity levels have difficulty maintaining a higher postoperative HRV, which is associated with a worse clinical outcome.

6.
Heart Rhythm ; 20(2): 217-223, 2023 02.
Article in English | MEDLINE | ID: mdl-36347456

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is an alternative strategy for His-bundle pacing (HBP); however, little is known about tricuspid regurgitation (TR) deterioration after LBBP implantation. OBJECTIVES: The purpose of this study was to characterize the incidence of post-LBBP TR deterioration and identify predicting factors, especially lead position parameters. METHODS: Patients who received LBBP were continuously enrolled from January 2018 to August 2020. The progression of TR and the anatomic position of LBBP were characterized by echocardiography. RESULTS: A total of 89 patients were enrolled and assigned to 2 subgroups based on the degree of TR before LBBP implantation: 58 (65.2%) with relatively normal tricuspid valve (TV) function (grade 0/1 subgroup: with none/trivial or mild TR) and 31 (34.8%) with more severe TR (grade 2/3 subgroup: with moderate or severe TR). At 19.0 ± 6.5 months of follow-up, 29 patients (32.6%) had TR deterioration, and 23 of them were in the grade 0/1 subgroup. In the grade 0/1 subgroup, patients with TR deterioration had a shorter distance between the lead-implanted site and TV (Lead-TA-dist) than those without TR (19.0 ± 7.6 vs 23.9 ± 5.4; P = .006). The receiver operating characteristic (ROC) curve (area under the curve 0.721; 95% confidence interval [CI] 0.575-0.867; P = .005) indicated the favorable efficacy of Lead-TA-dist for predicting TR deterioration after LBBP. Lead-TA-dist ≤16.1 mm was independently associated with TR deterioration after LBBP (hazard ratio 0.20; 95% CI 0.06-0.76; P = .017). CONCLUSION: TR was a common complication of LBBP implantation. In patients with none/trivial or mild TR, Lead-TA-dist ≤16.1 mm was an independent predictor of TR deterioration after LBBP implantation.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/etiology , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Time Factors , Bundle of His , Treatment Outcome , Electrocardiography
7.
Front Public Health ; 10: 1031241, 2022.
Article in English | MEDLINE | ID: mdl-36483238

ABSTRACT

Background: A substantial reduction in the number of cardiac implantable electronic device (CIED) implantation was reported in the early stages of the COVID-19 pandemic. None of the studies have yet explored changes in CIED implantation during the following pandemic. Objective: To explore changes in CIED implantation during the COVID-19 pandemic from 2020 to 2021. Methods: From 2019 to 2021, 177,263 patients undergone CIED implantation from 1,227 hospitals in China were included in the analysis. Generalized linear models measured the differences in CIED implantation in different periods. The relationship between changes in CIED implantation and COVID-19 cases was assessed by simple linear regression models. Results: Compared with the pre-COVID-19 period, the monthly CIED implantation decreased by 17.67% (95% CI: 16.62-18.72%, p < 0.001) in 2020. In 2021, the monthly number of CIED implantation increased by 15.60% (95% CI: 14.34-16.85%, p < 0.001) compared with 2020. For every 10-fold increase in the number of COVID-19 cases, the monthly number of pacemaker implantation decreased by 429 in 2021, while it decreased by 676 in 2020. The proportion of CIED implantation in secondary medical centers increased from 52.84% in 2019 to 56.77% in 2021 (p < 0.001). For every 10-fold increase in regional accumulated COVID-19 cases, the proportion of CIED implantation in secondary centers increased by 6.43% (95% CI: 0.47-12.39%, p = 0.036). Conclusion: The impact of the COVID-19 pandemic on the number of CIED implantation is diminishing in China. Improving the ability of secondary medical centers to undertake more operations may be a critical way to relieve the strain on healthcare resources during the epidemic.


Subject(s)
COVID-19 , Pandemics , Humans , COVID-19/epidemiology , China/epidemiology
8.
Front Public Health ; 10: 1027926, 2022.
Article in English | MEDLINE | ID: mdl-36504945

ABSTRACT

Background: The COVID-19 pandemic has significantly impacted routine cardiovascular health assessments and services. We aim to depict the temporal trend of catheter ablation (CA) and provide experience in dealing with the negative impact of the COVID-19 pandemic. Methods: Data on CA between January 2019, and December 2021, were extracted from the National Center for Cardiovascular Quality Improvement platform. CA alterations from 2019 to 2021 were assessed with a generalized estimation equation. Results: A total of 347,924 patients undergoing CA were included in the final analysis. The CA decreased remarkably from 122,839 in 2019 to 100,019 (-18.58%, 95% CI: -33.40% to -3.75%, p = 0.02) in 2020, and increased slightly to 125,006 (1.81%, 95% CI: -7.01% to 3.38%, p = 0.49) in 2021. The CA experienced the maximal reduction in February 2020 (-88.78%) corresponding with the peak of monthly new COVID-19 cases and decreased by 54.32% (95%CI: -71.27% to -37.37%, p < 0.001) during the 3-month lockdown and increased firstly in June 2020 relative to 2019. Since then, the CA in 2020 remained unchanged relative to 2019 (-0.06%, 95% CI: -7.01% to 3.38%, p = 0.98). Notably, the recovery of CA in 2021 to pre-COVID-19 levels was mainly driven by the growth of CA in secondary hospitals. Although there is a slight increase (2167) in CA in 2021 relative to 2019, both the absolute number and proportion of CA in the top 50 hospitals nationwide [53,887 (43.09%) vs. 63,811 (51.95%), p < 0.001] and top three hospitals in each province [66,152 (52.73%) vs. 72,392 (59.28%), p < 0.001] still declined significantly. Conclusions: The CA experienced a substantial decline during the early phase of the COVID-19 pandemic, and then gradually returned to pre-COVID-19 levels. Notably, the growth of CA in secondary hospitals plays an important role in the overall resumption, which implies that systematic guidance of secondary hospitals with CA experience may aid in mitigating the negative impact of the COVID-19 pandemic.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , Pandemics , Communicable Disease Control , Spatio-Temporal Analysis , Hospitals
9.
Front Cardiovasc Med ; 9: 928372, 2022.
Article in English | MEDLINE | ID: mdl-36225951

ABSTRACT

Background: Physical activity (PA) and resting heart rate (RHR) are connected with all-cause mortality. Moreover, there was an inverse correlation between PA and RHR. However, the causal relationship between PA, RHR, and long-term mortality has been rarely evaluated and quantified, particularly the mediation effect of RHR in the association between PA and all-cause mortality. Objective: To describe the relationship between PA and RHR when consistently measured via cardiac implantable electronic devices (CIED) and further explore the mediation effect of PA on all-cause mortality through RHR. Materials and methods: Patients who underwent CIED implantation and received remote home monitoring services were included. During the first 30-60 days after CIED implantation, daily PA and RHR were continuously measured and automatically transmitted by CIED. The primary endpoint was all-cause mortality. The multiple linear regression model was used to confirm the relationship between PA and RHR. The predictive values of both PA and RHR for all-cause mortality were assessed by multivariable Cox proportional hazards models. The causal mediation model was further established to verify and quantify the mediation effect of RHR in the association between PA and all-cause mortality. Results: A total of 730 patients with CIED were included. The mean daily PA and RHR were 10.7 ± 5.7% and 61.3 ± 9.1 bpm, respectively. During a mean follow-up period of 55.8 months, 187 (26.5%) death was observed. A negative linear relationship between PA and RHR was demonstrated in the multiple regression model (ß = -0.260; 95% CI: -0.377 to -0.143, p < 0.001). Multivariable Cox proportional hazards analysis showed that both lower levels of PA (HR = 0.907; 95% CI: 0.878-0.936, p < 0.001) and higher RHR (HR = 1.016; 95% CI: 1.001-1.032, P = 0.031) were independent risk factors of all-cause mortality. Causal mediation analysis further confirmed and quantified the mediation function of RHR in the process of PA improving all-cause mortality (mediation proportion = 3.9%; 95% CI: 0.2-10.0%, p = 0.036). Conclusion: The effects of the higher level of PA on improving life prognosis may be partially mediated through RHR among patients with CIED. It indicates that changes in the autonomic nervous function during postoperative rehabilitation exercises should get more attention.

10.
Front Physiol ; 13: 996640, 2022.
Article in English | MEDLINE | ID: mdl-36187788

ABSTRACT

Background: Left bundle branch pacing (LBBP) is an alternative strategy for His bundle pacing (HBP). This study aimed to analyze the long-term performance of LBBP and the potential factors affecting long-term cardiac function. Methods: Patients with LBBP were continuously enrolled from January 2018 to August 2020. Pacing parameters, electrocardiogram (ECG), and echocardiography were collected. The anatomic position of LBBP leads was described by echocardiographic and fluoroscopic parameters. Results: A total of 91 patients with a median follow-up of 18 months were enrolled. Most patients maintained stable pacing parameters during follow-up. The intra-septal position of the 3830 lead also remained stable as the distance from the lead tip to the left surface of the ventricular septum was 0.4 (0, 1.4) mm. The overall level of left ventricular ejection fraction (LVEF) slightly increased. 59 patients had improved LVEF (∆LVEF > 0), while 28 patients had unchanged or reduced LVEF (∆LVEF ≤ 0). The declines of baseline LVEF, ∆ Paced QRSd, and corrected longitudinal distance (longit-dist) of lead-implanted site correlated with LVEF improvement, and these three factors had negative linear correlations with ∆LVEF. Patients with tricuspid valve regurgitation (TVR) deterioration had longer follow-up duration (20.5 vs. 15.0 months, p = 0.01) and shorter Lead-TVA-dist (18.6 vs. 21.6 mm, p = 0.04) than those without TVR deterioration. Conclusion: Patients with LBBP generally remained stable in pacing performance, anatomic lead positions, and cardiac function in long-term follow-up. Baseline LVEF, ∆ Paced QRSd, and corrected longit-dist might be associated with potential LVEF decrease, which required further confirmation.

11.
Front Physiol ; 13: 912126, 2022.
Article in English | MEDLINE | ID: mdl-35991167

ABSTRACT

Background: Left bundle branch area pacing (LBBAP) has become a safe and effective option for heart failure (HF) patients indicated for cardiac resynchronization therapy (CRT) and/or ventricular pacing, yet the response rate was only 70%. Repolarization parameters were demonstrated to be associated with cardiac mechanics and systolic function. This study aimed to investigate the effects of LBBAP on repolarization parameters and the potential association between those parameters and echocardiographic response. Methods and results: A total of 59 HF patients undergoing successful LBBAP were consecutively included. QTc, Tpeak-Tend (TpTe), and TpTe/QTc were measured before and after the implantation. The results turned out that the dispersion of ventricular repolarization (DVR) improved after LBBAP among the total population. Although trends of repolarization parameters varied according to different QRS configurations at baseline, the post-implant parameters showed no significant difference between groups. The association between repolarization parameters and LBBAP response was then evaluated among patients with wide QRS. Multivariate analysis demonstrated that post-implant TpTe was the independent predictor of LBBAP response (p < 0.05). Receiver operating characteristic analysis indicated an area under the curve of 0.77 (95% CI, 0.60-0.93) with a cutoff value of 81.2 ms (p < 0.01). Patients with post-implant TpTe<81.2 ms had a significantly higher rate of echocardiographic response (93.3 vs. 44.4%, p < 0.01). Further subgroup analysis indicated that the predictive value of post-implant TpTe for LBBAP response was more significant in non-left bundle branch block (LBBB) patients than in LBBB patients. Conclusion: LBBAP improved DVR significantly in HF patients. Post-implant TpTe was associated with the echocardiographic response after LBBAP among patients with wide QRS, especially for non-LBBB patients.

12.
J Geriatr Cardiol ; 19(3): 177-188, 2022 Mar 28.
Article in English | MEDLINE | ID: mdl-35464647

ABSTRACT

OBJECTIVE: To evaluate the association of longitudinal changes in physical activity (PA) with long-term outcomes after implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) implantation. METHODS: Patients with ICD/CRT-D implantation from SUMMIT registry were retrospectively analyzed. Accelerometer-derived PA changes over 12 months post implantation were obtained from the archived home monitoring data. The primary endpoints were cardiac death and all-cause mortality. The secondary endpoints were the first ventricular arrthymia (VA) and first appropriate ICD shock. RESULTS: In 705 patients, 446 (63.3%) patients showed improved PA over 12 months after implantation. During a mean 61.5-month follow-up duration, 99 cardiac deaths (14.0%) and 153 all-cause deaths (21.7%) occurred. Compared to reduced/unchanged PA, improved PA over 12 months could result in significantly reduced risks of cardiac death (improved PA ≤ 30 min: hazard ratio (HR) = 0.494, 95% CI: 0.288-0.848; > 30 min: HR = 0.390, 95% CI: 0.235-0.648) and all-cause mortality (improved PA ≤ 30 min: HR = 0.467, 95%CI: 0.299-0.728; > 30 min: HR = 0.451, 95% CI: 0.304-0.669). No differences in the VAs or ICD shocks were observed across different groups of PA changes. PA changes can predict the risks of cardiac death only in the low baseline PA group, but improved PA was associated with 56.7%, 57.4%, and 62.3% reduced risks of all-cause mortality in the low, moderate, and high baseline PA groups, respectively, than reduced/unchanged PA. CONCLUSIONS: Improved PA could protect aganist cardiac death and all-cause mortality, probably reflecting better clinical efficacy after ICD/CRT-D implantation. Low-intensity exercise training might be encouraged among patients with different baseline PA levels.

13.
Clin Res Cardiol ; 111(11): 1219-1230, 2022 Nov.
Article in English | MEDLINE | ID: mdl-34761309

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is a novel near-physiological pacing method that still lacks quantitative criteria to guide the selection of lead-implanted sites to enhance the success likelihood of lead deployments. This study aimed to quantitatively analyze the relationships of LBBP success likelihood to the distribution of lead-implanted sites and the lead-localization-pacing electrocardiographic (ECG) features. METHODS: All the lead-implanted sites in patients with finally successful LBBP were enrolled for analysis, including successful and failed sites. A novel coordinate system was invented to describe the sites' distribution as longitudinal distance (longit-dist) and lateral distance (lat-dist). Corrected distance parameters were generated to eliminate the cardiac dimension variations. The lead-localization-pacing ECG parameters were also collected, such as paced QRS duration (locat-QRSd), left ventricular activation time (locat-LVAT), LVAT/QRSd ratio (locat-LVAT/QRSd), and QRS directions. RESULTS: A total of 94 patients with 105 successful sites and 93 failed sites were enrolled. Longit-dist and corrected longit-dist of successful sites were significantly longer, while locat-QRSd and locat-LVAT were shorter and locat-LVAT/QRSd was lower than failed sites. There was a positive dose-response relationship between LBBP success likelihood and corrected longit-dist with a cut-off of 26.95 mm, whereas there were negative dose-response relationships of LBBP success likelihood to locat-QRSd, locat-LVAT, and locat-LVAT/QRSd with the cut-offs of 142 ms, 92 ms, and 64.7%, respectively. Downward QRS direction in II/III ECG leads was also associated with successful LBBP. CONCLUSION: Longit-dist, locat-QRSd, locat-LVAT, and locat-LVAT/QRSd were quantitative parameters to guide the selection of lead-implanted sites during LBBP implantation. Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing. LBBP, left bundle branch pacing; Longit-dist, longitudinal distance; CL-apex-dist, distance from contraction line to apex; LBBB, left bundle branch block; IVCD, intraventricular conduction delay; Locat-QRSd, lead-localization-pacing QRS duration; Locat-LVAT, lead-localization-pacing left ventricular activation time; Locat-LVAT/QRSd, lead-localization-pacing LVAT/QRSd ratio.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Humans , Cardiac Pacing, Artificial/methods , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Electrocardiography/methods , Heart Conduction System
14.
JMIR Mhealth Uhealth ; 8(10): e22137, 2020 10 21.
Article in English | MEDLINE | ID: mdl-33084588

ABSTRACT

BACKGROUND: The potential effectiveness of integrated management in further improving the prognosis of patients with atrial fibrillation has been demonstrated; however, the best strategy for implementation remains to be discovered. OBJECTIVE: The aim of this study was to ascertain the feasibility of implementing integrated atrial fibrillation care via the Hospital-Community-Family-Based Telemedicine (HCFT-AF) program. METHODS: In this single-arm, pre-post design pilot study, a multidisciplinary teamwork, supported by efficient infrastructures, provided patients with integrated atrial fibrillation care following the Atrial fibrillation Better Care (ABC) pathway. Eligible patients were continuously recruited and followed up for at least 4 months. The patients' drug adherence, and atrial fibrillation-relevant lifestyles and behaviors were assessed at baseline and at 4 months. The acceptability, feasibility, and usability of the HCFT-AF technology devices and engagement with the HCFT-AF program were assessed at 4 months. RESULTS: A total of 73 patients (mean age, 68.42 years; 52% male) were enrolled in November 2019 with a median follow up of 132 days (IQR 125-138 days). The patients' drug adherence significantly improved after the 4-month intervention (P<.001). The vast majority (94%, 64/68) of indicated patients received anticoagulant therapy at 4 months, and none of them received antiplatelet therapy unless there was an additional indication. The atrial fibrillation-relevant lifestyles and behaviors ameliorated to varying degrees at the end of the study. In general, the majority of patients provided good feedback on the HCFT-AF intervention. More than three-quarters (76%, 54/71) of patients used the software or website more than once a week and accomplished clinic visits as scheduled. CONCLUSIONS: The atrial fibrillation-integrated care model described in this study is associated with improved drug adherence, standardized therapy rate, and lifestyles of patients, which highlights the possibility to better deliver integrated atrial fibrillation management. TRIAL REGISTRATION: Clinicaltrials.gov NCT04127799; https://clinicaltrials.gov/ct2/show/NCT04127799.


Subject(s)
Atrial Fibrillation , Telemedicine , Aged , Anticoagulants/therapeutic use , Atrial Fibrillation/drug therapy , Feasibility Studies , Female , Humans , Male , Pilot Projects
15.
BMC Cardiovasc Disord ; 19(1): 178, 2019 07 26.
Article in English | MEDLINE | ID: mdl-31349811

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) significantly increases the risk of ischemic stroke depending on various risk factors. The CHA2DS2-VASc score is used widely to improve stratification of AF-related stroke to identify for whom anticoagulation could be safely withheld. As upstream therapy, the management of lifestyle for AF and related stroke prevention has been ongoing for past decades. CASE PRESENTATION: A 56-year-old male was taken to our hospital because of acute ischemic stroke. Without intracranial vascular malformation and angiostenosis, two small emboli were successfully taken out from the left middle cerebral artery by mechanical thrombectomy. During the hospitalisation, no apparent abnormalities were found in various laboratory tests, echocardiogram or the coronary computed tomography angiography. However, asymptomatic paroxysmal AF was first diagnosed and was presumed to be responsible for his stroke. Noticeable, he was always in good fitness benefiting from the formed good habits of no smoking and drinking. With a CHA2DS2-VASc score of 0, he had no history of any known diseases or risk factors associated with AF and related stroke. Instead of lacking exercise, he persisted in playing table tennis faithfully 3-4 times a week and 2-3 h each time over the past 30 years, and, in fact, has won several amateur table tennis championships. CONCLUSION: In view of the possible pathophysiological mechanisms resulting from the long-term vigorous endurance exercise, it may be a potential risk factor for developing AF and even for subsequent stroke. Not merely should strengthen the screening for AF in specific individuals as sports enthusiasts, but the necessity of oral anticoagulant for those with a CHA2DS2-VASc score of 0 might deserve the further investigation.


Subject(s)
Atrial Fibrillation/complications , Brain Ischemia/etiology , Exercise , Intracranial Embolism/etiology , Stroke/etiology , Administration, Oral , Anticoagulants/administration & dosage , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Brain Ischemia/diagnostic imaging , Brain Ischemia/physiopathology , Brain Ischemia/therapy , Clinical Decision-Making , Humans , Intracranial Embolism/diagnostic imaging , Intracranial Embolism/physiopathology , Intracranial Embolism/therapy , Male , Middle Aged , Physical Endurance , Risk Assessment , Risk Factors , Stroke/diagnostic imaging , Stroke/physiopathology , Stroke/therapy , Thrombectomy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...