Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bone Rep ; 14: 100753, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33665236

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the efficacy and toxicity of a novel lanthanum compound, La(XT), in an ovariectomized (OVX) rat model of osteoporosis. METHODS: Twenty-four ovariectomized female Sprague Dawley rats were divided into 3 groups receiving a research diet with/without treatment compounds (alendronate: 3 mg/kg; La(XT) 100 mg/kg) for three months. At the time of sacrifice, the kidney, liver, brain, lung and spleen were collected for histological examination. The trabecular bone structure of the tibiae was evaluated using micro-CT and a three-point metaphyseal mechanical test was used to evaluate bone failure load and stiffness. RESULTS: No significant differences were noted in plasma levels of calcium, phosphorus, creatinine, alanine aminotransferase (ALT), and aspartate aminotransferase (AST) between the La(XT) treatment compared to the non-treated OVX group. Alendronate-treated animals (positive control) showed higher BV/TV, Tb.N and lower Tb.Th and Tb.Sp when compared to the non-treated OVX group. Mechanical analysis indicated that stiffness was higher in the alendronate (32.88%, p = 0.04) when compared to the non-treated OVX group. Failure load did not differ among the groups. CONCLUSIONS: No kidney or liver toxicities of La(XT) treatments were found during the three-month study. The absence of liver and kidney toxicity with drug treatment for 3 months, as well as the increased trabecular bone stiffness are encouraging for the pursuit of further studies with La(XT) for a longer duration of time.

2.
Ann Biomed Eng ; 41(5): 1084-93, 2013 May.
Article in English | MEDLINE | ID: mdl-23358801

ABSTRACT

Colonoscopy is the most sensitive and specific means for detection of colon cancers and polyps. To make colonoscopy more effective several problems must be overcome including: pain associated with the procedure, the risk of perforation, and incomplete intubation colonoscopy. Technically, these problems are the result of loop formation during colonoscopy. Although, several solutions such as modifying the stiffness of the colonoscope, using an overtube and developing image-guided instruments have been introduced to resolve the looping problem, the results of these systems are not completely satisfactory. A new paradigm to overcome loop formation is proposed that is doctor-assistive colonoscopy. In this approach, the endoscopists performance is enhanced by providing using a kinetic model that provides information such as the shape of the scope, direction of the colon and forces exerted within certain sections. It is expected that with the help of this model, the endoscopist would be able to adjust the manipulation to avoid loop formation. In the present studies, the kinetic model is developed and validated using an ex vivo colonoscopy test-bed with a comprehensive kinematic and kinetic data collection. The model utilizes an established colon model based on animal tissue with position tracking sensors, contact force sensors for the intraluminal portion of the scope and a Colonoscopy Force Monitor for the external insertion tube.


Subject(s)
Colon , Colonoscopes , Colonoscopy/methods , Models, Biological , Animals , Colonoscopy/instrumentation , Humans , Kinetics , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...