1.
Sensors (Basel) ; 23(3)2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36772645

ABSTRACT

A method for detecting the surface defects of high reflection objects using phase deflection is proposed. The abrupt change in the surface gradient at the defect leads to the change in the fringe phase. Therefore, Gray code combined with a four-step phase-shift method was employed to obtain the surface gradients to characterize the defects. Then, through the double surface illumination model, the relationship between illumination intensity and phase was established. The causes of periodic error interference were analyzed, and the method of adjusting the fringe width to eliminate it was proposed. Finally, experimental results showed the effectiveness of the proposed method.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(10): 2858-62, 2014 Oct.
Article in Chinese | MEDLINE | ID: mdl-25739238

ABSTRACT

Long Wavelength Near InfraRed (LW-NIR) spectrometer has wide applications. Miniaturization and low-cost are two major goals of the development of LW-NIR spectrometer in the industrial or research community. Under the background that having a trend of spectrometer miniaturization and integration, method and main problems involved in miniaturization of LW-NIR spectrometer through MEMS scanning mirror, such as the design strategy of the light-splitting optical system, selection considerations of the MEMS scanning mirror, design method of the preamplifier circuit, etc, have been presented in detail. A prototype of miniaturized LW-NIR spectrometer, with the spectrum range of detection of 900-2,055 nm, is designed and implemented using MEMS scanning mirror, InGaAs single detector unit with high sensitivity. Littrow optical layout is used for its light-splitting optical system, and the spectral resolution is between 9.4-16 nm at 1,000-1,965 nm detection wavelength range. The prototype is successfully applied in LW-NIR spectrum measurement on pure water and ethanol aqueous solution, and a forecast analysis on ethanol aqueous solution concentration is also demonstrated. Through adopting MEMS scanning mirror into the spectrometer system, the complexity of the mechanical scanning fixtures and its controlling mechanism is greatly reduced therefore the size of the spectrometer is reduced. Furthermore, due to MEMS scanning mirror technology, LW-NIR spectrometer with single InGaAs detector is achieved, thus the cost reduction of the NIR spectrometer system is also realized because the expensive InGaAs arrays are avoided.

SELECTION OF CITATIONS
SEARCH DETAIL
...