Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 79(10): 10E317, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044479

ABSTRACT

A spectral resolution measurement of the x-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research machine utilizing a segmented position-sensitive detector and time-to-digital converter based delay-line readout electronics was performed by using an x-ray tube in a laboratory. The measured spectral resolution is about 12,600, which means the actual energy resolution is 0.32 eV for the x-ray tube's bremsstrahlung peak energy of 4 keV. The results from the spectral resolution measurement are described.

2.
Rev Sci Instrum ; 78(10): 103504, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17979416

ABSTRACT

A versatile time-to-digital converter based data acquisition system for a segmented position-sensitive detector has been developed. This data acquisition system was successfully demonstrated to a two-segment position-sensitive detector. The data acquisition system will be developed further to support multisegmented position-sensitive detector to improve the photon count rate capability of the advanced x-ray imaging crystal spectrometer system.


Subject(s)
Crystallography/instrumentation , Information Storage and Retrieval/methods , Signal Processing, Computer-Assisted/instrumentation , Spectrometry, X-Ray Emission/instrumentation , Transducers , Crystallography/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, X-Ray Emission/methods
3.
Rev Sci Instrum ; 78(6): 063504, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17614609

ABSTRACT

An advanced x-ray imaging crystal spectrometer (XICS) for KSTAR tokamak has been developed by utilizing a segmented two dimensional (2D) position-sensitive multiwire proportional counter. The XICS for the KSTAR tokamak provides time-resolved measurements of the radial ion and electron temperature profiles, toroidal plasma rotation velocity, and ionization equilibrium. The segmented 2D detector with delay-line readout and supporting electronics has been adopted to improve the photon count rate capability. The current fabrication status of the XICS for the KSTAR tokamak and the first performance test results of the prototype segmented 2D detector are presented.


Subject(s)
Radiometry/instrumentation , Spectrometry, X-Ray Emission/instrumentation , Equipment Design , Equipment Failure Analysis , Radiation Dosage , Radiometry/methods , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, X-Ray Emission/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...