Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
FASEB J ; 27(4): 1664-73, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23271050

ABSTRACT

The underlying mechanisms of itch are poorly understood. We have investigated a model involving the chemoattractant leukotriene B4 (LTB4) that is up-regulated in common skin diseases. Intradermal injection of LTB4 (0.1 nmol/site) into female CD1 mice induced significant scratching movements (used as an itch index) compared with vehicle-injected (0.1% bovine serum albumin-saline) mice. Intraperitoneal transient receptor potential (TRP) channel antagonist treatment significantly inhibited itch as follows: TRP vanilloid 1 (TRPV1) antagonist SB366791 (0.5 mg/kg, by 97%) and the TRP ankyrin 1 (TRPA1) antagonists TCS 5861528 (10 mg/kg; 82%) and HC-030031 (100 mg/kg; 76%). Leukotriene B4 receptor 2 antagonism by LY255283 (5 mg/kg i.p.; 62%) reduced itch. Neither TRPV1-knockout (TRPV1-KO) nor TRPA1-knockout (TRPA1-KO mice exhibited LTB4-induced itch compared with their wild-type counterparts. The reactive oxygen species scavengers N-acetylcysteine (NAC; 204 mg/kg i.p.; 86%) or superoxide dismutase (SOD; 10 mg/kg i.p.; 83%) also inhibited itch. LTB4-induced superoxide release was attenuated by TCS 5861528 (56%) and HC-030031 (66%), NAC (58%), SOD (50%), and LY255283 (59%) but not by the leukotriene B4 receptor 1 antagonist U-75302 (9 nmol/site) or SB366791. Itch, superoxide, and myeloperoxidase generation were inhibited by the leukocyte migration inhibitor fucoidan (10 mg/kg i.v.) by 80, 61, and 34%, respectively. Myeloperoxidase activity was also reduced by SB366791 (35%) and SOD (28%). TRPV1-KO mice showed impaired myeloperoxidase release, whereas TRPA1-KO mice exhibited diminished production of superoxide. This result provides novel evidence that TRPA1 and TRPV1 contribute to itch via distinct mechanisms.


Subject(s)
Leukocytes/metabolism , Leukotriene B4/pharmacology , Superoxides/metabolism , Transient Receptor Potential Channels/metabolism , Animals , Ankyrins/pharmacology , Female , Leukocytes/drug effects , Mice , Mice, Knockout , Pruritus/drug therapy , Pruritus/metabolism , Receptors, Leukotriene B4/antagonists & inhibitors , TRPV Cation Channels/metabolism
2.
Gastrointest Endosc ; 75(3): 484-90, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21963069

ABSTRACT

BACKGROUND: Complete colonoscopy examination cannot be performed in as many as 10% of cases. The new 9.2-mm ultrathin colonoscope (UTC) with an extra bending section may improve procedure tolerance and allow improvement in colonoscopy completion rate compared with a 12.9-mm standard colonoscope (SC). OBJECTIVE: To compare the performance of the 9.2-mm UTC with that of the 12.9-mm SC. DESIGN: Prospective, randomized, controlled trial. SETTING: Academic endoscopic unit. PATIENTS: Subjects 18 years and older undergoing their first colonoscopy. INTERVENTION: Subjects were randomized to either the UTC or SC group. MAIN OUTCOME MEASUREMENTS: First and rescue successful cecal intubation rates, subject satisfaction scores, and sedation requirements were compared. RESULTS: A total of 1121 patients (56% women, mean age 53.6 years) were randomized to the UTC group (n = 551) or the SC group (n = 570). There was no statistically significant difference in the first successful cecal intubation rate between the UTC and SC groups (98.9% vs 97.4%, P = .057). The mean (standard deviation) dose of midazolam and pethidine used was significantly lower in the UTC group (2.65 [0.65] mg vs 2.82 [0.85] mg, P < .001 and 27.6 [7.4] mg vs 29.7 [9.6] mg, P < .001, respectively). The mean (standard deviation) patient satisfaction score was similar between groups (6.99 [2.89] vs 7.04 [3.06], P = .762). Of the 21 patients (1.9%) with an incomplete initial colonoscopy (6 in the UTC group and 15 in the SC group), all 6 in the UTC group had their procedure completed with an SC. Eleven of 15 patients in the SC group had their procedures completed with a UTC in the same session. LIMITATIONS: Low failure rate may mask any difference between the 2 colonoscopes as a rescue instrument. CONCLUSIONS: The 9.2-mm UTC has performance characteristics similar to those of an SC in Chinese subjects undergoing their first colonoscopy performed by experienced and trainee endoscopists. ( CLINICAL TRIAL REGISTRATION NUMBER: NCT01142167.).


Subject(s)
Cecum , Colonoscopes , Intubation/statistics & numerical data , Patient Satisfaction , Equipment Design , Female , Humans , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...