Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Eur Heart J Cardiovasc Imaging ; 19(5): 562-568, 2018 05 01.
Article in English | MEDLINE | ID: mdl-29053805

ABSTRACT

Aims: The relationship between echocardiographic measures of left ventricular (LV) systolic function and reference-standard measures have not been assessed in children. The objective of this study was to assess the validity of echocardiographic indices of LV systolic function via direct comparison to a novel composite measure of contractility derived from pressure-volume loop (PVL) analysis. Methods and results: Children with normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. A composite invasive composite contractility index (ICCI) was developed using data reduction strategies to combine four measures of contractility derived from PVL analysis. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Conventional and speckle-tracking echocardiographic measures of systolic function were measured. Of 24 patients, 18 patients were heart transplant recipients, 6 patients had a small patent ductus arteriosus or small coronary fistula. Mean age was 9.1 ± 5.6 years. Upon multivariable regression, longitudinal strain was associated with ICCI (ß = -0.54, P = 0.02) while controlling for indices of preload, afterload, heart rate, and LV mass under baseline conditions. Ejection fraction and shortening fraction were associated with LV mass and load indices, but not contractility. Conclusion: Speckle-tracking derived longitudinal strain is associated ICCI in children with normal loading conditions. Longitudinal measures of deformation appear to accurately assess LV contractility in children.


Subject(s)
Cardiac Catheterization/methods , Echocardiography/methods , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Image Interpretation, Computer-Assisted , Ventricular Function, Left/physiology , Adolescent , Child , Child, Preschool , Cohort Studies , Echocardiography, Three-Dimensional/methods , Female , Hospitals, University , Humans , Male , Monitoring, Physiologic/methods , Myocardial Contraction/physiology , Prognosis , Prospective Studies , Stroke Volume/physiology
2.
J Am Soc Echocardiogr ; 31(3): 342-348.e1, 2018 03.
Article in English | MEDLINE | ID: mdl-29246510

ABSTRACT

BACKGROUND: Pediatric heart transplant recipients are at risk for increased left ventricular (LV) diastolic stiffness. However, the noninvasive evaluation of LV stiffness has remained elusive in this population. The objective of this study was to compare novel echocardiographic measures of LV diastolic stiffness versus gold-standard measures derived from pressure-volume loop (PVL) analysis in pediatric heart transplant recipients. METHODS: Patients undergoing left heart catheterization were prospectively enrolled. PVLs were obtained via conductance. The end-diastolic pressure-volume relationship was obtained via balloon occlusion. The stiffness constant, ß, was calculated. Echocardiographic measures of diastolic function were derived from spectral and tissue Doppler and two-dimensional speckle-tracking. Ventricular volumes were measured using three-dimensional echocardiography. The novel echocardiographic estimates of ventricular stiffness included E:e'/end-diastolic volume (EDV) and E:early diastolic strain rate/EDV. RESULTS: Of 24 children, 18 were heart transplant recipients. Six control patients had hemodynamically insignificant patent ductus arteriosus or coronary fistula. The mean age was 9.1 ± 5.6 years. Median end-diastolic pressure was 9 mm Hg (interquartile range, 8-13 mm Hg). Lateral E:e'/EDV (r = 0.59, P < .01), septal E:e'/EDV (r = 0.57, P < .01), and (E:circumferential early diastolic strain rate)/EDV (r = 0.54, P < .01) correlated with ß. Lateral E:e'/EDV displayed a C statistic of 0.93 in detecting patients with abnormal LV stiffness (ß > 0.015 mL-1). A lateral E:e'/EDV of >0.15 mL-1 had 89% sensitivity and 93% specificity in detecting an abnormal ß. CONCLUSIONS: Echocardiographic estimates of ventricular stiffness may be accurate compared with the gold standard in pediatric heart transplant recipients. The clinical usefulness of these noninvasive measures in assessing LV stiffness merits further study in children.


Subject(s)
Echocardiography, Three-Dimensional/methods , Heart Defects, Congenital/surgery , Heart Transplantation/adverse effects , Heart Ventricles/diagnostic imaging , Transplant Recipients , Ventricular Dysfunction, Left/diagnosis , Adolescent , Cardiac Catheterization/methods , Child , Child, Preschool , Diastole , Female , Follow-Up Studies , Heart Ventricles/physiopathology , Humans , Infant , Infant, Newborn , Male , Pilot Projects , Prospective Studies , Stroke Volume/physiology , Ventricular Dysfunction, Left/physiopathology , Young Adult
3.
Pediatr Cardiol ; 38(1): 27-35, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27655413

ABSTRACT

The accuracy of echocardiographic measures of right ventricular (RV) diastolic function has been sparsely studied. Our objective was to evaluate the correlation between echocardiographic and reference standard measures of RV diastolic function derived from micromanometer pressure analysis before and after preload alteration in children. Echocardiograms and micromanometer pressure analyses were prospectively performed before and after fluid bolus in children undergoing right heart catheterization. The isovolumic relaxation time constant (τ) and end-diastolic pressure (EDP) were measured. Conventional and speckle-tracking echocardiographic (STE) parameters of RV systolic and diastolic function were assessed. Normal saline bolus was given to increase RV EDP by 20 %. Twenty-eight studies were performed in 22 patients with congenital heart disease or postheart transplantation. Mean age was 8.7 ± 6.1 years. RV longitudinal early diastolic strain rate (EDSR) correlated with τ before (r = 0.57, p = 0.001) and after fluid bolus (r = 0.48, p = 0.008). No conventional echocardiographic measures correlated with τ both before and after fluid bolus. Multiple regression analysis revealed RV EDSR and LV circumferential EDSR as independent predictors of RV τ. There were no independent predictors of EDP. RV EDSR appears to correlate with the reference standard measure of early active ventricular relaxation in children at baseline and after changes in preload. Conventional echocardiographic measures of diastolic function were not predictive of diastolic function after preload alteration. Future studies should assess the prognostic significance of STE measures of diastolic function in this population.


Subject(s)
Cardiac Catheterization/methods , Echocardiography/methods , Heart Defects, Congenital/physiopathology , Heart Ventricles/diagnostic imaging , Ventricular Function, Right/physiology , Adolescent , Blood Volume/physiology , Child , Child, Preschool , Diastole , Female , Heart Defects, Congenital/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Manometry , Prospective Studies , Reference Standards , Sodium Chloride/administration & dosage
4.
J Am Soc Echocardiogr ; 29(7): 640-7, 2016 07.
Article in English | MEDLINE | ID: mdl-27025669

ABSTRACT

BACKGROUND: The accuracy of echocardiography in evaluating left ventricular contractility has not been validated in children. The objective of this study was to compare echocardiographic measures of contractility with those derived from pressure-volume loop (PVL) analysis in children. METHODS: Patients with relatively normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. The gold-standard measure of contractility, end-systolic elastance (Ees), was obtained via balloon occlusion of one or both vena cavae. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Single-beat estimations of echocardiographic Ees were calculated using four different methods. These estimates were calculated using a combination of noninvasive blood pressure readings, ventricular volumes derived from three-dimensional echocardiography, and Doppler time intervals. RESULTS: Of 24 patients, 18 patients were heart transplant recipients, and six patients had small patent ductus arteriosus or small coronary fistulae. The mean age was 9.1 ± 5.6 years. The average invasive Ees was 3.04 ± 1.65 mm Hg/mL. Invasive Ees correlated best with echocardiographic Ees by the method of Tanoue (r = 0.85, P < .01), with a mean difference of -0.07 mm Hg/mL (95% limits of agreement, -2.0 to 1.4 mm Hg/mL). CONCLUSIONS: Echocardiographic estimates of Ees correlate well with gold-standard measures obtained via conductance catheters in children with relatively normal loading conditions. The use of these noninvasive measures in accurately assessing left ventricular contractility appears promising and merits further study in children.


Subject(s)
Blood Pressure Determination/methods , Cardiac Catheterization/methods , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Myocardial Contraction/physiology , Stroke Volume , Ventricular Function, Left/physiology , Child , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
5.
J Am Soc Echocardiogr ; 21(3): 230-3, 2008 Mar.
Article in English | MEDLINE | ID: mdl-17904813

ABSTRACT

INTRODUCTION: We used 3-dimensional (3D) echocardiography to identify and quantify left ventricular (LV) dyssynchrony in children with LV dysfunction compared with control subjects. METHODS: The 3D echocardiography LV full volumes were acquired in 18 children, 9 with LV dysfunction and 9 control subjects. The LV was subdivided into 16 segments (apex excluded). Time from end diastole to the minimal systolic volume for each segment was expressed as a percent of the R-R interval. The SD of these times provided a 16-segment dyssynchrony index (16-SDI). The second index (12-SDI) was similarly calculated using 6 basal and 6 mid segments. The third index consisted of 6 basal segments (6-SDI). RESULTS: The dysfunction group exhibited significantly increased 16-SDI (P = .008) and 12-SDI (P = .01). The 16-SDI was negatively correlated with 3D ejection fraction and 2-dimensional fractional shortening. CONCLUSIONS: Children with LV dysfunction demonstrate increased intraventricular LV dyssynchrony by 3D echocardiography, in a pattern that is negatively correlated with LV systolic function.


Subject(s)
Echocardiography, Three-Dimensional/methods , Image Interpretation, Computer-Assisted/methods , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Fibrillation/complications , Ventricular Fibrillation/diagnostic imaging , Child , Child, Preschool , Humans , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic
6.
Echocardiography ; 23(3): 225-31, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16524393

ABSTRACT

OBJECTIVE: We sought to determine whether three-dimensional echocardiography (3DE) is useful in the evaluation of patients with atrioventricular septal defect (AVSD). BACKGROUND: Recent advances in 3DE have enhanced its practicality. We assessed whether 3DE provided new information compared to 2DE among patients with AVSD. METHODS: We retrospectively reviewed 52 3DE datasets from 51 patients (median age: 4.6 years, range 0-30 years; median BSA: 0.6 m2, range 0.2-1.9 m2) with any type of AVSD during a 1-year period. 3DE findings were compared to 2DE and surgical reports. For each study, AVSD was classified by 2DE as one of the following: unrepaired balanced defect, repaired balanced defect with residual lesions, repaired balanced defect without residual lesions, or unbalanced defect. 3DE was graded as (1) Additive: 3DE resulted in a new finding or changed diagnosis; (2) Useful: While useful, 3DE did not result in new findings or changed diagnosis; or (3) Not useful. RESULTS: 3DE on unrepaired balanced AVSD and repaired AVSD with residual lesions was more often additive/useful (33/36; 92%) than on repaired AVSD without residual lesions or unbalanced AVSD (9/16 (56%), P=0.009). 3DE was additive or useful in all three patients with unbalanced AVSD being considered for biventricular repair. Useful information obtained by 3DE included: precise characterization of mitral regurgitation and cleft leaflet, substrate for subaortic stenosis, valve anatomy, and presence and location of additional septal defects. CONCLUSION: 3DE provides useful and additive information in unrepaired balanced AVSD, repaired AVSD with residual lesions, and unbalanced AVSD under consideration for biventricular repair.


Subject(s)
Echocardiography, Three-Dimensional , Heart Defects, Congenital/diagnostic imaging , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Ventricular/diagnostic imaging , Adolescent , Adult , Chi-Square Distribution , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...