Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 87
Filter
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658126

ABSTRACT

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
3.
Article in English | MEDLINE | ID: mdl-38599918

ABSTRACT

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

4.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
5.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38552656

ABSTRACT

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Adolescent , Adult , Aged , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Cardiovasc Revasc Med ; 58: 60-67, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37550123

ABSTRACT

BACKGROUND: Patients with high bleeding risk (HBR) are often treated with abbreviated dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) to reduce bleeding risk, however this strategy is associated with an increase in ischemic events, especially if the acute PCI result is suboptimal. We compared clinical outcomes among patients with HBR treated with 1-month DAPT who underwent intravascular ultrasound (IVUS)- or optical coherence tomography (OCT)-guided PCI versus those who underwent angiography-guided PCI without intravascular imaging. METHODS: The Onyx ONE Clear study includes patients with HBR from the Onyx ONE US/Japan and Onyx ONE randomized studies who were treated with the Resolute Onyx zotarolimus-eluting stent. The primary endpoint was the composite of cardiac death (CD) or myocardial infarction (MI) between 1 month and 2 years after PCI. Propensity-score adjustments and matching were performed for differences in baseline and procedural characteristics between groups. RESULTS: Among the 1507 patients in Onyx ONE Clear, 271 (18.0 %) had IVUS or OCT used during PCI (Imaging-guided group) and 1236 (82.0 %) underwent Angiography-guided PCI (Angio-guided group). Imaging-guided patients were less likely to present with atrial fibrillation, acute coronary syndrome, and left ventricle ejection fraction ≤35 %. Conversely, Imaging-guided patients were more likely to have complex (ACC/AHA type B2/C), longer, and heavily calcified lesions. Between 1 month and 2 years, the composite rate of CD or MI was similar between Imaging-guided and Angio-guided patients (9.9 % vs. 12.4 %, P = 0.33). There was also no difference between groups after adjustment; (P = 0.56). However, CD was significantly lower among Imaging-guided patients (2.7 % vs. 6.1 %, P = 0.048). There were no between-group differences in MI or stent thrombosis. Propensity score matching results were similar. CONCLUSION: Despite higher lesion complexity, using intravascular imaging guidance for PCI between 1-month and 2-years follow-up had comparable outcomes with angiographic guidance alone in patients with HBR treated with 1-month DAPT. (ClinicalTrials.gov: Identifier: NCT03647475 and NCT03344653). NON-STANDARD ABBREVIATIONS AND ACRONYMS: BARC: Bleeding Academic Research Consortium; DAPT: dual antiplatelet therapy; DES: drug-eluting stent; HBR: high bleeding risk; IVUS: intravascular ultrasound; OCT: optical coherence tomography; SAPT: single antiplatelet therapy.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Coronary Angiography/adverse effects , Coronary Angiography/methods , Drug-Eluting Stents/adverse effects , Myocardial Infarction/therapy , Myocardial Infarction/drug therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/adverse effects , Treatment Outcome , Prospective Studies
7.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38110018

ABSTRACT

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Follow-Up Studies , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Surgical Instruments , Prosthesis Design , Risk Factors
8.
Am J Cardiol ; 213: 99-105, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38110022

ABSTRACT

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Male , Female , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Treatment Outcome , Registries , North America
9.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37812864

ABSTRACT

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Quality of Life , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography , Risk Factors
10.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37438029

ABSTRACT

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheters
11.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Article in English | MEDLINE | ID: mdl-37480877

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Atrial Fibrillation/epidemiology , Stroke Volume , Heart Atria , Prosthesis Implantation , Prognosis
12.
Struct Heart ; 7(3): 100164, 2023 May.
Article in English | MEDLINE | ID: mdl-37273856

ABSTRACT

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

13.
JACC Cardiovasc Interv ; 16(8): 942-953, 2023 04 24.
Article in English | MEDLINE | ID: mdl-37100557

ABSTRACT

BACKGROUND: Aortic stenosis treatment should consider risks and benefits for lifetime management. Although the feasibility of redo transcatheter aortic valve replacement (TAVR) remains unclear, concerns are emerging regarding reoperation after TAVR. OBJECTIVES: The authors sought to define comparative risk of surgical aortic valve replacement (SAVR) after prior TAVR or SAVR. METHODS: Data on patients undergoing bioprosthetic SAVR after TAVR and/or SAVR were extracted from the Society of Thoracic Surgeons Database (2011-2021). Overall and isolated SAVR cohorts were analyzed. The primary outcome was operative mortality. Risk adjustment using hierarchical logistic regression as well as propensity score matching for isolated SAVR cases were performed. RESULTS: Of 31,106 SAVR patients, 1,126 had prior TAVR (TAVR-SAVR), 674 had prior SAVR and TAVR (SAVR-TAVR-SAVR), and 29,306 had prior SAVR (SAVR-SAVR). Yearly rates of TAVR-SAVR and SAVR-TAVR-SAVR increased over time, whereas SAVR-SAVR was stable. The TAVR-SAVR patients were older, with higher acuity, and with greater comorbidities than other cohorts. The unadjusted operative mortality was highest in the TAVR-SAVR group (17% vs 12% vs 9%, respectively; P < 0.001). Compared with SAVR-SAVR, risk-adjusted operative mortality was significantly higher for TAVR-SAVR (OR: 1.53; P = 0.004), but not SAVR-TAVR-SAVR (OR: 1.02; P = 0.927). After propensity score matching, operative mortality of isolated SAVR was 1.74 times higher for TAVR-SAVR than SAVR-SAVR patients (P = 0.020). CONCLUSIONS: The number of post-TAVR reoperations is increasing and represent a high-risk population. Yet even in isolated SAVR cases, SAVR after TAVR is independently associated with increased risk of mortality. Patients with life expectancy beyond a TAVR valve and unsuitable anatomy for redo-TAVR should consider a SAVR-first approach.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Risk Factors
14.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Article in English | MEDLINE | ID: mdl-36882136

ABSTRACT

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Male , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Risk Factors , Treatment Outcome , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/surgery
15.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922042

ABSTRACT

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , United States , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Critical Pathways , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis/adverse effects
16.
Catheter Cardiovasc Interv ; 101(4): 756-763, 2023 03.
Article in English | MEDLINE | ID: mdl-36748804

ABSTRACT

BACKGROUND: TandemHeart has been demonstrated to improve hemodynamic and metabolic complications in cardiogenic shock (CS). Contemporary outcomes have not been reported. OBJECTIVES: To evaluate the outcomes of the TandemHeart (LivaNova) in contemporary real-world use. METHODS: We analyzed baseline characteristics, hemodynamic changes, and outcomes of all patients treated with TandemHeart who were enrolled in the THEME registry, a multicenter, prospective, observational study. RESULTS: Between May 2015 and June 2019, 50 patients underwent implantation of the TandemHeart device. 22% of patients had TandemHeart implanted within 12 h, 32% within 24 h, and 52% within 48 h of CS diagnosis. Cardiac index (CI) was significantly improved 24 h after implantation (median change 1.0, interquartile range (IQR) (0.5-1.4 L/min/m2 ). In survivors, there was a significant improvement in CI (1.0, IQR (0.5-2.25 L/min/m2 ) and lactate clearance -2.3 (-5.0 to -0.7 mmol/L). The 30-day and 180-day survival were 74% (95% confidence interval: 60%-85%) and 66% (95% confidence interval: 51%-79%), respectively. Survival was similarly high in those in whom TandemHeart has been used as a bridge to surgery (85% 180-day survival). CONCLUSION: In a contemporary cohort of patients presenting in CS, the use of TandemHeart is associated with a 74% 30-day survival and a 66% 180-day survival.


Subject(s)
Heart-Assist Devices , Shock, Cardiogenic , Humans , Shock, Cardiogenic/therapy , Prospective Studies , Heart-Assist Devices/adverse effects , Treatment Outcome , Registries
17.
JACC Cardiovasc Interv ; 16(2): 168-176, 2023 01 23.
Article in English | MEDLINE | ID: mdl-36697152

ABSTRACT

BACKGROUND: The 30-day rate of stroke after transcatheter aortic valve replacement (TAVR) has been suggested as a hospital quality metric. Thirty-day stroke rates for nonsurgical, high, and moderate-risk TAVR trials were 3.4% to 6.1%, whereas those in the national Transcatheter Valve Therapy (TVT) Registry for the same patient population were much lower. Hospital comprehensive stroke center (CSC) is the highest designation for integrated acute stroke recognition, management, and care. OBJECTIVES: Using Michigan TVT data, we assessed whether in-hospital post-TAVR stroke rates varied between CSC and non-CSC institutions. METHODS: TVT data submitted from the 22 Michigan Transcatheter Aortic Valve Replacement Collaborative participating institutions between January 1, 2016, and June 30, 2019, were included (N = 6,231). Bayesian hierarchical regression models accounting for patient clinical characteristics and hospital clustering were fitted to assess the association between hospital CSC accreditation and in-hospital post-TAVR stroke. Adjusted ORs and 95% credible intervals were estimated. The University of Michigan Institutional Review Board has waived the need for the approval of studies based on the data collected by the Blue Cross Blue Shield of Michigan Cardiovascular Consortium registry. RESULTS: There were 3,882 (62.3%) patients at 9 CSC sites and 2,349 (37.7%) patients at 13 non-CSC sites. CSC sites had significantly higher rates of in-hospital post-TAVR stroke (CSC: 2.65% vs non-CSC: 1.15%; P < 0.001). After adjustment, patients who underwent TAVR at a CSC hospital had a significantly higher risk of in-hospital stroke (adjusted OR: 2.21; 95% CI: 1.03-4.62). However, CSC designation was not significantly associated with other important post-TAVR clinical outcomes including 30-day mortality. CONCLUSIONS: Reported Michigan Transcatheter Aortic Valve Replacement Collaborative TVT stroke rates were significantly higher at sites with Joint Hospital Commission stroke designation status; however, other reported important clinical outcomes did not differ significantly based on this designation. CSC designation is a possible factor in stroke rate detection differences between TAVR institutions and might be a factor in the observed differences in stroke rates between TAVR trials and those reported in TVT. In addition, these data suggest that comparison between hospitals based on post-TAVR stroke rates is potentially problematic.


Subject(s)
Aortic Valve Stenosis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Michigan/epidemiology , Bayes Theorem , Treatment Outcome , Stroke/diagnosis , Stroke/epidemiology , Hospitals , Registries , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
18.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36515976

ABSTRACT

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Female , Aortic Valve/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
19.
J Thorac Cardiovasc Surg ; 165(6): 2011-2020.e5, 2023 06.
Article in English | MEDLINE | ID: mdl-34538638

ABSTRACT

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement since its approval, the frequency and outcomes of aortic valve reintervention after transcatheter aortic valve replacement are poorly understood. METHODS: Valve reinterventions, either surgical transcatheter aortic valve explantation or repeat transcatheter aortic valve replacement, between 2012 and 2019 were queried using the Society of Thoracic Surgeons Database and the Transcatheter Valve Therapy Registry through the Michigan Statewide quality collaborative. The reintervention frequency and clinical outcomes including observed-to-expected mortality ratio using Society of Thoracic Surgeons Predicted Risk of Mortality were reviewed. RESULTS: Among 9694 transcatheter aortic valve replacement recipients, a total of 87 patients (0.90%) received a reintervention, consisting of 34 transcatheter aortic valve explants and 53 repeat transcatheter aortic valve replacement procedures. The transcatheter aortic valve explant group demonstrated a higher Society of Thoracic Surgeons Predicted Risk of Mortality. Reintervention cases increased from 0 in 2012 and 2013 to 26 in 2019. The proportion of transcatheter aortic valve explants among all reinterventions increased and was 65% in 2019. Self-expandable devices had a higher reintervention rate than balloon-expandable devices secondary to a higher transcatheter aortic valve explant frequency (0.58% [23/3957] vs 0.19% [11/5737]; P = .001), whereas repeat transcatheter aortic valve replacement rates were similar (0.61% [24/3957] vs 0.51% [29/5737]; P = .51). Among patients with transcatheter aortic valve explants, contraindications to repeat transcatheter aortic valve replacement included unfavorable anatomy (75%), need for other cardiac surgery (29%), other structural issues by transcatheter aortic valve device (18%), and endocarditis (12%). For transcatheter aortic valve explant and repeat transcatheter aortic valve replacement, the 30-day mortality was 15% and 2% (P = .032) and the observed-to-expected mortality ratio was 1.8 and 0.3 (P = .018), respectively. CONCLUSIONS: Aortic valve reintervention remains rare but is increasing. The clinical impact of surgical device explantation was substantial, and the proportion of transcatheter aortic valve explants was significantly higher in patients with a self-expandable device.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Prosthesis Design , Risk Factors
20.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36001335

ABSTRACT

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Female , Heart Valve Prosthesis/adverse effects , Humans , Male , Prospective Studies , Stroke/epidemiology , Stroke/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...