Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 96(1): 364-372, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38156894

ABSTRACT

We have developed a statistical model-based approach to the quality analysis (QA) and quality control (QC) of a gas micro pre-concentrator chip (µPC) performance when manufactured at scale for chemical and biochemical analysis of volatile organic compounds (VOCs). To test the proposed model, a medium-sized university-led production batch of 30 wafers of chips were subjected to rigorous chemical performance testing. We quantitatively report the outcomes of each manufacturing process step leading to the final functional chemical sensor chip. We implemented a principal component analysis (PCA) model to score individual chip chemical performance, and we observed that the first two principal components represent 74.28% of chemical testing variance with 111 of 118 viable chips falling into the 95% confidence interval. Chemical performance scores and chip manufacturing data were analyzed using a multivariate regression model to determine the most influential manufacturing parameters and steps. In our analysis, we find the amount of sorbent mass present in the chip (variable importance score = 2.6) and heater and the RTD resistance values (variable importance score = 1.1) to be the manufacturing parameters with the greatest impact on chemical performance. Other non-obvious latent manufacturing parameters also had quantified influence. Statistical distributions for each manufacturing step will allow future large-scale production runs to be statistically sampled during production to perform QA/QC in a real-time environment. We report this study as the first data-driven, model-based production of a microfabricated chemical sensor.

2.
J Chromatogr A ; 1705: 464151, 2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37419015

ABSTRACT

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert­butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1-5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.


Subject(s)
Natural Gas , Odorants , Humans , Odorants/analysis , Sulfhydryl Compounds/analysis , Sulfur Compounds/analysis
3.
Micromachines (Basel) ; 13(11)2022 Nov 02.
Article in English | MEDLINE | ID: mdl-36363914

ABSTRACT

A bonding process was developed for glass-to-glass fusion bonding using Borofloat 33 wafers, resulting in high bonding yield and high flexural strength. The Borofloat 33 wafers went through a two-step process with a pre-bond and high-temperature bond in a furnace. The pre-bond process included surface activation bonding using O2 plasma and N2 microwave (MW) radical activation, where the glass wafers were brought into contact in a vacuum environment in an EVG 501 Wafer Bonder. The optimal hold time in the EVG 501 Wafer bonder was investigated and concluded to be a 3 h hold time. The bonding parameters in the furnace were investigated for hold time, applied force, and high bonding temperature. It was concluded that the optimal parameters for glass-to-glass Borofloat 33 wafer bonding were at 550 °C with a hold time of 1 h with 550 N of applied force.

4.
J Breath Res ; 16(3)2022 05 26.
Article in English | MEDLINE | ID: mdl-35508102

ABSTRACT

Exhaled breath vapor contains hundreds of volatile organic compounds (VOCs), which are the byproducts of health and disease metabolism, and they have clinical and diagnostic potential. Simultaneous collection of breath VOCs and background environmental VOCs is important to ensure analyses eliminate exogenous compounds from clinical studies. We present a mobile sampling system to extract gaseous VOCs onto commercially available sorbent-packed thermal desorption tubes. The sampler can be connected to a number of commonly available disposable and reusable sampling bags, in the case of this study, a Tedlar bag containing a breath sample. Alternatively, the inlet can be left open to directly sample room or environmental air when obtaining a background VOC sample. The system contains a screen for the operator to input a desired sample volume. A needle valve allows the operator to control the sample flow rate, which operates with an accuracy of -1.52 ± 0.63% of the desired rate, and consistently generated that rate with 0.12 ± 0.06% error across repeated measures. A flow pump, flow sensor and microcontroller allow volumetric sampling, as opposed to timed sampling, with 0.06 ± 0.06% accuracy in the volume extracted. Four samplers were compared by sampling a standard chemical mixture, which resulted in 6.4 ± 4.7% error across all four replicate modular samplers to extract a given VOC. The samplers were deployed in a clinical setting to collect breath and background/environmental samples, including patients with active SARS-CoV-2 infections, and the device could easily move between rooms and can undergo required disinfection protocols to prevent transmission of pathogens on the case exterior. All components required for assembly are detailed and are made publicly available for non-commercial use, including the microcontroller software. We demonstrate the device collects volatile compounds, including use of chemical standards, and background and breath samples in real use conditions.


Subject(s)
Breath Tests , Environmental Monitoring , Volatile Organic Compounds , Breath Tests/methods , COVID-19/prevention & control , Environmental Monitoring/methods , Exhalation , Humans , SARS-CoV-2/isolation & purification , Volatile Organic Compounds/analysis
5.
J Environ Sci (China) ; 103: 135-147, 2021 May.
Article in English | MEDLINE | ID: mdl-33743896

ABSTRACT

Trace analysis of volatile organic compounds (VOCs) during wildfires is imperative for environmental and health risk assessment. The use of gas sampling devices mounted on unmanned aerial vehicles (UAVs) to chemically sample air during wildfires is of great interest because these devices move freely about their environment, allowing for more representative air samples and the ability to sample areas dangerous or unreachable by humans. This work presents chemical data from air samples obtained in Davis, CA during the most destructive wildfire in California's history - the 2018 Camp Fire - as well as the deployment of our sampling device during a controlled experimental fire while fixed to a UAV. The sampling mechanism was an in-house manufactured micro-gas preconcentrator (µPC) embedded onto a compact battery-operated sampler that was returned to the laboratory for chemical analysis. Compounds commonly observed in wildfires were detected during the Camp Fire using gas chromatography mass spectrometry (GC-MS), including BTEX (benzene, toluene, ethylbenzene, m+p-xylene, and o-xylene), benzaldehyde, 1,4-dichlorobenzene, naphthalene, 1,2,3-trimethylbenzene and 1-ethyl-3-methylbenzene. Concentrations of BTEX were calculated and we observed that benzene and toluene were highest with average concentrations of 4.7 and 15.1 µg/m3, respectively. Numerous fire-related compounds including BTEX and aldehydes such as octanal and nonanal were detected upon experimental fire ignition, even at a much smaller sampling time compared to samples taken during the Camp Fire. Analysis of the air samples taken both stationary during the Camp Fire and mobile during an experimental fire show the successful operation of our sampler in a fire environment.


Subject(s)
Air Pollutants , Volatile Organic Compounds , Air Pollutants/analysis , Benzene , California , Environmental Monitoring , Gas Chromatography-Mass Spectrometry , Humans , Toluene/analysis , Volatile Organic Compounds/analysis , Xylenes
SELECTION OF CITATIONS
SEARCH DETAIL
...