Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Water Health ; 21(12): 1908-1921, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38153720

ABSTRACT

The present study aimed to assess chemical risks in the drinking water of inhabitants in the basin of the Tonle Sap Great Lake. Water samples from tube wells (n = 52), dug wells (n = 13), stored rain water (n = 39), ponds/lakes (n = 19), canals/rivers (n = 24), and household pipe water (n = 45) were collected and analyzed for physicochemical properties, as well as microbial and chemical qualities using standard methods. Analytical results revealed that 42.1% of tube wells had As > 10 µg L-1 while 8.3% had Cr > 0.05 mg L-1. Concurrently, 55.2 and 11.8% of tube wells had Cd > 3.00 µg L-1 and Pb > 10 µg L-1, respectively. Moreover, 35.0% of pipe water had Fe > 0.3 mg L-1, whereas 85.7% of tube wells and 69.2% of dug wells had Mn > 0.1 mg L-1. All water sources including pipe water could pose risks of non-carcinogenic effects of chemical mixtures to all exposure groups through their drinking water pathway. Children were at a higher risk of chemical mixtures in their drinking water than adults. This study suggests that advanced treatment technologies should be applied to the current water treatment plants to provide inhabitants with safe drinking water.


Subject(s)
Drinking Water , Adult , Child , Humans , Lakes , Ponds , Rain , Rivers
2.
Nanoscale Res Lett ; 12(1): 351, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28506026

ABSTRACT

ZnO nanorods (NRs) arrays doped with a large concentration of Mn synthesized by aqueous chemical growth and were characterized by SEM, photoluminescence, Raman scattering, magnetic force microscopy (MFM). By comparison of spectra taken on pure and Mn-doped ZnO NRs, a few new Raman impurity-related phonon modes, resulting from the presence of Mn in the investigated samples. We also present a vibrational and magnetic characterization of individual lying nanorods using Raman and MFM imaging. Confocal scanning micro-Raman mapping of the spatial distribution of intensity and frequency of phonon modes in single Mn-doped ZnO NRs nanorods is presented and analyzed for the first time. Mn-related local vibrational modes are also registered in Raman spectra of the single nanorod, confirming the incorporation of Mn into the ZnO host matrix. At higher Mn concentration the structural transformation toward the spinel phase ZnMn2O4 and Mn3O4 is observed mainly in 2D bottom layers. MFM images of Mn-doped ZnO NR arrays and single nanorod were studied in nanoscale at room temperature and demonstrate magnetic behavior. The circular domain magnetic pattern on top of single nanorod originated to superposition of some separate domains inside rod. This demonstrates that long-range ferromagnetic order is present at room temperature. Aligned Mn-doped ZnO NRs demonstrates that long-range ferromagnetic order and may be applied to future spintronic applications.

3.
Sensors (Basel) ; 12(11): 15063-77, 2012 Nov 06.
Article in English | MEDLINE | ID: mdl-23202200

ABSTRACT

A potentiometric glucose biosensor based on immobilization of glucose oxidase (GOD) on ZnO nanorods (ZnO-NRs) has been developed for the indirect determination of environmental mercury ions. The ZnO-NRs were grown on a gold coated glass substrate by using the low temperature aqueous chemical growth (ACG) approach. Glucose oxidase in conjunction with a chitosan membrane and a glutaraldehyde (GA) were immobilized on the surface of the ZnO-NRs using a simple physical adsorption method and then used as a potentiometric working electrode. The potential response of the biosensor between the working electrode and an Ag/AgCl reference electrode was measured in a 1mM phosphate buffer solution (PBS). The detection limit of the mercury ion sensor was found to be 0.5 nM. The experimental results provide two linear ranges of the inhibition from 0.5 × 10(-6) mM to 0.5 × 10(-4) mM, and from 0.5 × 10(-4) mM to 20 mM of mercury ion for fixed 1 mM of glucose concentration in the solution. The linear range of the inhibition from 10(-3) mM to 6 mM of mercury ion was also acquired for a fixed 10 mM of glucose concentration. The working electrode can be reactivated by more than 70% after inhibition by simply dipping the used electrode in a 10 mM PBS solution for 7 min. The electrodes retained their original enzyme activity by about 90% for more than three weeks. The response to mercury ions was highly sensitive, selective, stable, reproducible, and interference resistant, and exhibits a fast response time. The developed glucose biosensor has a great potential for detection of mercury with several advantages such as being inexpensive, requiring minimum hardware and being suitable for unskilled users.


Subject(s)
Biosensing Techniques , Glucose/analysis , Mercury/analysis , Nanotubes , Zinc Oxide/chemistry , Enzymes, Immobilized/metabolism , Glucose Oxidase/metabolism , Hydrogen-Ion Concentration , Limit of Detection , Microscopy, Electron, Scanning , Reproducibility of Results
4.
Biosensors (Basel) ; 1(4): 153-63, 2011 Oct 27.
Article in English | MEDLINE | ID: mdl-25585565

ABSTRACT

In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed.

SELECTION OF CITATIONS
SEARCH DETAIL
...