Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
2.
BMC Musculoskelet Disord ; 24(1): 553, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37408033

ABSTRACT

BACKGROUND: Preoperative prediction of prolonged postoperative opioid use (PPOU) after total knee arthroplasty (TKA) could identify high-risk patients for increased surveillance. The Skeletal Oncology Research Group machine learning algorithm (SORG-MLA) has been tested internally while lacking external support to assess its generalizability. The aims of this study were to externally validate this algorithm in an Asian cohort and to identify other potential independent factors for PPOU. METHODS: In a tertiary center in Taiwan, 3,495 patients receiving TKA from 2010-2018 were included. Baseline characteristics were compared between the external validation cohort and the original developmental cohorts. Discrimination (area under receiver operating characteristic curve [AUROC] and precision-recall curve [AUPRC]), calibration, overall performance (Brier score), and decision curve analysis (DCA) were applied to assess the model performance. A multivariable logistic regression was used to evaluate other potential prognostic factors. RESULTS: There were notable differences in baseline characteristics between the validation and the development cohort. Despite these variations, the SORG-MLA ( https://sorg-apps.shinyapps.io/tjaopioid/ ) remained its good discriminatory ability (AUROC, 0.75; AUPRC, 0.34) and good overall performance (Brier score, 0.029; null model Brier score, 0.032). The algorithm could bring clinical benefit in DCA while somewhat overestimating the probability of prolonged opioid use. Preoperative acetaminophen use was an independent factor to predict PPOU (odds ratio, 2.05). CONCLUSIONS: The SORG-MLA retained its discriminatory ability and good overall performance despite the different pharmaceutical regulations. The algorithm could be used to identify high-risk patients and tailor personalized prevention policy.


Subject(s)
Arthroplasty, Replacement, Knee , Opioid-Related Disorders , Humans , Analgesics, Opioid/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Machine Learning , Algorithms , Prescriptions , Retrospective Studies
3.
J Formos Med Assoc ; 122 Suppl 1: S82-S91, 2023.
Article in English | MEDLINE | ID: mdl-37353444

ABSTRACT

BACKGROUND: Previous epidemiological researchers have used various algorithms to identify a second hip fracture; however, there has been no validation of these algorithms to date. This study aimed to verify existing algorithms for identifying second hip fracture under the International Classification of Diseases diagnostic coding systems. Furthermore, we examined the validity of two newly proposed algorithms that integrated the concept of periprosthetic fractures and laterality of the ICD-10 coding system. METHODS: Claims data of patients hospitalized for hip fracture from National Taiwan University Hospitals between 2007 and 2020 were retrieved. Hip fracture was confirmed by 2 orthopaedic surgeons with medical records and imaging data as gold standards. The validity of 9 existing and 2 newly proposed algorithms for identifying second hip fracture was evaluated. RESULTS: The positive predictive value (PPV) range between 84% and 90% in existing algorithms for identifying second hip fractures. Noteworthy, the longer time interval for discrimination resulted in slightly increased PPV (from 87% to 90%), while decreased sensitivity noticeably (from 87% to 72%). When considering the information about periprosthetic fracture, the PPV increased to 91% without diminished sensitivity. The PPV of the newly proposed ICD-10-specific algorithm was 100%. CONCLUSION: Algorithms integrated clinical insights of periprosthetic fractures and laterality concept of ICD-10 coding system provided satisfactory validity and help precisely define second hip fracture in future database research.


Subject(s)
Hip Fractures , Periprosthetic Fractures , Humans , Taiwan/epidemiology , Hip Fractures/diagnosis , Hip Fractures/epidemiology , Medical Records , Algorithms
4.
BMC Musculoskelet Disord ; 23(1): 916, 2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36242041

ABSTRACT

OBJECTIVE: Antibiotic-loaded bone cement beads and spacers have been widely used for orthopaedic infection. Poor antibiotic elution is not capable of eradicating microbial pathogens and could lead to treatment failure. The elution profiles differ among different cement formulations. Although Simplex P cement has the least release amount, it is widely used due to its ready availability. Previous methods aiming to improve the elution profiles were not translated well to clinical practice. We sought to address this by using easily available materials to improve the elution profile of antibiotics from PMMA, which allows clinicians to implement the method intraoperatively. METHODS: Vancomycin was mixed with Simplex P cement. We used Vicryl Rapide sutures to fabricate sustained-release cement beads by repetitively passing the sutures through the beads and/or mixing suture segments into the cement formulation. Vancomycin elution was measured for 49 days. The mechanism of antibiotic release was observed with gross appearance and scanning electron microscopic images. The antimicrobial activities against MRSA were tested using an agar disk diffusion bioassay. RESULTS: Passing Vicryl Rapide sutures through cement beads significantly improved the elution profiles in the 7-week period. The increased ratios were 9.0% on the first day and 118.0% from the 2nd day to the 49th day. Addition of suture segments did not increase release amount. The Vicryl Rapide sutures completely degraded at the periphery and partially degraded at the center. The antibiotic particles were released around the suture, while antibiotic particles kept densely entrapped in the control group. The antimicrobial activities were stronger in passing suture groups. CONCLUSION: Passing fast absorbable sutures through PMMA cement is a feasible method to fabricate sustained-release antibiotic bone cement. Intra-cement tunnels can be formed, and the effect can last for at least 7 weeks. It is suitable for a temporary spacer between two stages of a revision surgery.


Subject(s)
Bone Cements , Polymethyl Methacrylate , Agar , Anti-Bacterial Agents , Delayed-Action Preparations , Humans , Methylmethacrylate , Polyglactin 910 , Sutures , Vancomycin
6.
Pharmaceutics ; 14(3)2022 Mar 10.
Article in English | MEDLINE | ID: mdl-35335980

ABSTRACT

BACKGROUND: Meniscus tissue engineering has yet to achieve clinical application because it requires chondrogenic induction and in vitro cell expansion. Contrarily, cartilage engineering from autologous chondrocytes has been successfully applied in one-stage surgery. If the natural chondrogenic potential of meniscus cells can be demonstrated, meniscus tissue engineering would have more value in clinical settings. MATERIALS AND METHODS: In total, 10 menisci and pieces of cartilage were obtained during total knee replacements. The tissues were collected for cell isolation and expansion. Their chondrogenic properties were examined by immunohistofluorescence and gene expression analyses. RESULTS: In native cartilage, immunofluorescence demonstrated the presence of collagen I, aggrecan, and traces of collagen I, whereas comparable staining was seen in the inner and middle meniscus. The presence of collagen I but the absence of collagen II and aggrecan were observed in the outer meniscus. In passage 2, chondrocytes showed the presence of collagen II and aggrecan, and the absence of vimentin. The vimentin and aggrecan staining were comparable in the inner and middle meniscus cells, whereas the outer cells showed only vimentin staining. In the gene expression analyses, the expressions of collagen II and aggrecan in the native chondrocyte and the inner and middle meniscus were higher than those of the cells from the outer meniscus, but they were not different in collagen I. In the passage 2 culture, chondrocytes had a higher expression of collagen II and aggrecan than the meniscus cells. Cells from the inner and middle areas had higher collagen II and aggrecan expression than those from the outer meniscus. CONCLUSION: Without chondrogenic induction, inner and middle meniscus cells possess a chondrogenic phenotype. Specifically, native meniscus cells exhibited more robust chondrogenic potential compared with those of the passage 2 monolayer culture.

7.
Spine J ; 22(7): 1119-1130, 2022 07.
Article in English | MEDLINE | ID: mdl-35202784

ABSTRACT

BACKGROUND CONTEXT: Preoperative prediction of prolonged postoperative opioid prescription helps identify patients for increased surveillance after surgery. The SORG machine learning model has been developed and successfully tested using 5,413 patients from the United States (US) to predict the risk of prolonged opioid prescription after surgery for lumbar disc herniation. However, external validation is an often-overlooked element in the process of incorporating prediction models in current clinical practice. This cannot be stressed enough in prediction models where medicolegal and cultural differences may play a major role. PURPOSE: The authors aimed to investigate the generalizability of the US citizens prediction model SORG to a Taiwanese patient cohort. STUDY DESIGN: Retrospective study at a large academic medical center in Taiwan. PATIENT SAMPLE: Of 1,316 patients who were 20 years or older undergoing initial operative management for lumbar disc herniation between 2010 and 2018. OUTCOME MEASURES: The primary outcome of interest was prolonged opioid prescription defined as continuing opioid prescription to at least 90 to 180 days after the first surgery for lumbar disc herniation at our institution. METHODS: Baseline characteristics were compared between the external validation cohort and the original developmental cohorts. Discrimination (area under the receiver operating characteristic curve and the area under the precision-recall curve), calibration, overall performance (Brier score), and decision curve analysis were used to assess the performance of the SORG ML algorithm in the validation cohort. This study had no funding source or conflict of interests. RESULTS: Overall, 1,316 patients were identified with sustained postoperative opioid prescription in 41 (3.1%) patients. The validation cohort differed from the development cohort on several variables including 93% of Taiwanese patients receiving NSAIDS preoperatively compared with 22% of US citizens patients, while 30% of Taiwanese patients received opioids versus 25% in the US. Despite these differences, the SORG prediction model retained good discrimination (area under the receiver operating characteristic curve of 0.76 and the area under the precision-recall curve of 0.33) and good overall performance (Brier score of 0.028 compared with null model Brier score of 0.030) while somewhat overestimating the chance of prolonged opioid use (calibration slope of 1.07 and calibration intercept of -0.87). Decision-curve analysis showed the SORG model was suitable for clinical use. CONCLUSIONS: Despite differences at baseline and a very strict opioid policy, the SORG algorithm for prolonged opioid use after surgery for lumbar disc herniation has good discriminative abilities and good overall performance in a Han Chinese patient group in Taiwan. This freely available digital application can be used to identify high-risk patients and tailor prevention policies for these patients that may mitigate the long-term adverse consequence of opioid dependence: https://sorg-apps.shinyapps.io/lumbardiscopioid/.


Subject(s)
Intervertebral Disc Displacement , Opioid-Related Disorders , Algorithms , Analgesics, Opioid/adverse effects , Humans , Intervertebral Disc Displacement/drug therapy , Intervertebral Disc Displacement/surgery , Machine Learning , Prescriptions , Retrospective Studies
8.
Int Orthop ; 44(9): 1745-1754, 2020 09.
Article in English | MEDLINE | ID: mdl-32367232

ABSTRACT

PURPOSE: Autologous minced cartilage has been used to repair cartilage defects. We have developed a biphasic cylindrical osteochondral construct for such use in human knees, and report the five year post-operative outcomes. METHODS: Ten patients with symptomatic osteochondral lesion at femoral condyles were treated by replacing pathological tissue with the osteochondral composites, each consisted a DL-poly-lactide-co-glycolide chondral phase and a DL-poly-lactide-co-glycolide/ß-tricalcium phosphate osseous phase. A flat chamber between the two phases served as a reservoir to house double-minced (mechanical pulverization and enzymatical dissociation) autologous cartilage graft. The osteochondral lesion was drill-fashioned a pit of identical dimensions as the construct. Graft-laden construct was press fit to the pit. Post-operative outcome was evaluated using Knee Injury and Osteoarthritis Outcome Score (KOOS) up to five years. Regenerated tissue was sampled with arthroscopic needle biopsy for histology at one year, and imaged with magnetic resonance at one, three, and five years to evaluate the neocartilage with MOCART chart. Subchondral bone integration was evaluated with computed tomography at three and five years. RESULTS: Nine patients completed the five-year follow-up. Post-operative mean KOOS, except that of the "symptom" subscale, had been significantly higher than pre-operation from one year and maintained to five years. The change of MOCRAT scores of the regenerated cartilage paralleled the change of KOOS. The osseous phase remained mineralized during the five-year period, yet did not fully integrate with the host bone. CONCLUSIONS: This novel construct for chondrocyte implantation yielded promising mid-term outcome. It repaired the osteochondral lesion with hyaline-like cartilage durable for at least five years.


Subject(s)
Cartilage Diseases , Cartilage, Articular , Cartilage, Articular/surgery , Chondrocytes , Feasibility Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Magnetic Resonance Imaging , Transplantation, Autologous
9.
Regen Ther ; 15: 97-102, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33426207

ABSTRACT

In articular cartilage-repair, grafts usually fuse unsatisfactorily with surrounding host cartilage. Enzymatic dissociation of cartilaginous matrix to free chondrocytes may benefit fusion. We tested such a hypothesis with human cartilage in vitro, and with porcine cartilage in vivo. Human articular cartilage was collected from knee surgeries, cut into disc-and-ring sets, and randomly distributed into three groups: disc-and-ring sets in Group 1 were left untreated; in Group 2 only discs, and in Group 3 both discs and rings were treated with enzyme. Each disc-and-ring reassembly was cultured in a perfusion system for 14 days; expression of cartilage marker proteins and genes was evaluated by immunohistochemistry and PCR. Porcine articular cartilage from knees was similarly fashioned into disc-and-ring combinations. Specimens were randomly distributed into a control group without further treatment, and an experimental group with both disc and ring treated with enzyme. Each disc-and-ring reassembly was transplanted into subcutaneous space of a nude mouse for 30 days, and retrieved to examine disc-ring interface. In in vitro study with human cartilage, a visible gap remained at disc-ring interfaces in Group 1, yet became indiscernible in Group 2 and 3. Marker genes, including type II collagen, aggrecan and Sox 9, were well expressed by chondrocytes in all specimens, indicating that chondrocytes' phenotype retained regardless of enzymatic treatment. Similar results were found inin vivo study with porcine cartilage. Enzymatic dissociation of cartilaginous matrix promotes fusion of adjacent cartilage. The clinical relevance may be a novel method to facilitate integration of repaired cartilage in joints.

10.
Carbohydr Polym ; 229: 115496, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-31826425

ABSTRACT

Chondroitin sulfates (CS) account for more than 80% of the glycosaminoglycans of articular cartilage, which impart its physiological functions. We quantified the absolute concentration of the CS components of the full thickness cartilages from the knees of patients with terminal-phase osteoarthritis. Osteochondrol biopsies were removed from the medial femoral condyle and lateral femoral condyle of sixty female patients received total knee arthroplasty, aged from 58 to 83 years old. We found the total CS concentrations and chondroitin-4-sulfate disaccharide were significantly lowered in osteoarthritic samples. Microstructure analysis indicated while chondroitin-0-sulfate was equally distributed across different zones of the osteoarthritic cartilages, chondroitin-4-sulfate is significantly less in the deep zones. Down-regulation of sulfotransferases, the enzymes responsible for CS sulfation, in the lesion site of cartilage were observed. Our study suggested chondroitin-4-sulfate down-regulation can be a diagnostic marker for degraded osteoarthritis cartilage, with potential implications in cartilage regeneration.


Subject(s)
Cartilage, Articular/metabolism , Chondroitin Sulfates/metabolism , Osteoarthritis/metabolism , Aged , Aged, 80 and over , Cartilage, Articular/pathology , Female , Gene Expression Regulation , Humans , Male , Middle Aged , Osteoarthritis/pathology
11.
Arch Phys Med Rehabil ; 100(11): 2046-2052, 2019 11.
Article in English | MEDLINE | ID: mdl-31082379

ABSTRACT

OBJECTIVES: To evaluate the effects of vibration on Achilles' tendon microcirculation and characteristics following surgical repair of Achilles' tendon rupture. DESIGN: Cohort study with historical controls. SETTING: A university institute. PARTICIPANTS: Participants (N=32), including 19 (16 men, 3 women; median [range] age: 43.0 [25.0-57.0] years) and 13 (10 men, 3 women; 44.00 [29.0-60.0] years) in the vibration (application to the ball of the foot, 30Hz, 2mm amplitude, 4kg pressure, and self-administration) and control groups, respectively, who underwent unilateral Achilles' tendon repairs were recruited. INTERVENTION: A 4-week vibration intervention in the vibration group. MAIN OUTCOME MEASUREMENTS: The tendon microcirculation was measured after the first session of vibration. The participants were evaluated repeatedly with bilateral follow-up measurements of tendon stiffness, 3 functional outcome tests, and a questionnaire survey. RESULTS: Acute effects of the vibration were observed immediately after the 5-minute vibration (P≤.001). Lower total hemoglobin and oxygen saturation were respectively observed (P=.043) in the repaired legs 3 and 6 months postsurgery in the vibration group as compared with the control group. The vibration group also showed greater tendon stiffness, heel raising height and hopping distance 3 or 6 months postoperation in both the repaired and noninjured legs (all P<.05). The microcirculatory characteristics 2 months postoperation were correlated with the outcomes at 6 months postoperation. CONCLUSIONS: Differences in microcirculatory characteristics and better rehabilitation outcomes were observed in the legs with an Achilles repair that underwent the early vibration intervention.


Subject(s)
Achilles Tendon/blood supply , Achilles Tendon/injuries , Microcirculation/physiology , Tendon Injuries/rehabilitation , Vibration/therapeutic use , Achilles Tendon/physiopathology , Adult , Female , Hemoglobins/analysis , Humans , Male , Middle Aged , Oxygen/blood , Physical Therapy Modalities , Prospective Studies , Range of Motion, Articular , Recovery of Function , Tendon Injuries/physiopathology , Tendon Injuries/surgery
12.
Foot Ankle Int ; 40(5): 568-577, 2019 May.
Article in English | MEDLINE | ID: mdl-30654659

ABSTRACT

BACKGROUND: The purpose of the study was to compare the morphomechanical and functional characteristics during maximal isometric, concentric, and eccentric contractions in the legs of patients that underwent unilateral Achilles tendon repair with those in their noninjured control legs. METHODS: Twenty participants (median age = 38.2 years; range, 21.1-57.3 years) who underwent Achilles repair between 3 and 12 months ago were recruited with the following measures: (1) mechanical stiffness of the aponeurosis and (2) electromyography and medial gastrocnemius fascicle angle and length, standing muscle and tendon length, and height of heel rise with isometric contraction. RESULTS: Compared to the noninjured legs, the repaired legs showed less resting fascicle length, standing muscle length, isometric plantarflexion torque, and heel raise distance ( Ps ranged between .044 and <.001). During the concentric and eccentric phases of the raising and lowering test, the repaired legs demonstrated less fascicle length ( P ≤ .028) but greater tendinous tissue length ( Ps ranged between .084 and <.001) and fascicle angle ( Ps ranged between .247 and .008) and fewer change magnitudes of the fascicle length and tendinous tissue length ( P ≤ .003). The change magnitudes of the morphological characteristics showed correlations with the torque or distance. CONCLUSION: Selecting the appropriate surgical repair and rehabilitation for Achilles tendon ruptures is recommended for restoring the length and mechanical strength of the muscle-tendon unit of plantar-flexion muscles. LEVEL OF EVIDENCE: Level III, comparative study.


Subject(s)
Achilles Tendon/physiopathology , Achilles Tendon/surgery , Muscle Contraction , Muscle, Skeletal/physiopathology , Achilles Tendon/injuries , Adult , Electromyography , Female , Humans , Male , Middle Aged , Ultrasonography , Young Adult
13.
J Surg Res ; 215: 167-172, 2017 07.
Article in English | MEDLINE | ID: mdl-28688643

ABSTRACT

BACKGROUND: Staple removal from surgical wounds is painful. Only a few articles have provided expert opinions using anesthetic cream for such a problem; however, direct application of the anesthetic cream to a wound may cause infection. A safe alternative can be an anesthetic patch without wound contact. MATERIALS AND METHODS: This was a prospective, double-blind, randomized clinical trial. Sixty patients who underwent primary total knee replacement were assigned to an experimental group or control group. One lidocaine patch was applied around the surgical wound for each patient in the experimental group. Alternatively, the adhesive sides of the lidocaine patches were shielded with waterproof films in the control group. A resident peeled off the patch before a single nursing practitioner removed the staples. Pain was assessed with the 10-cm visual analog scale, and a face pain scale-revised was performed. The patients and the nursing practitioner were blind to the management. RESULTS: Mean visual analog scale and face pain scale-revised scores were significantly lower in the experimental group. The mean pain score was significantly lower in the experimental group if the application time was >47 min; for patients with application time of 47 min or shorter, the score was comparable with the mean pain scores of the control group (P = 0.215). CONCLUSIONS: Removal of the metal skin staples after total knee arthroplasty is associated with moderate-to-severe pain. The lidocaine patch applied topically around the surgical wound could effectively reduce the pain during the procedure, without remarkable complications such as systemic adverse effects or wound contamination.


Subject(s)
Anesthesia, Local/methods , Anesthetics, Local/administration & dosage , Arthroplasty, Replacement, Knee , Device Removal , Lidocaine/administration & dosage , Surgical Wound/surgery , Sutures , Administration, Topical , Adult , Aged , Aged, 80 and over , Anesthesia, Local/instrumentation , Double-Blind Method , Female , Follow-Up Studies , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Pain Measurement , Prospective Studies
14.
PM R ; 9(1): 32-39, 2017 01.
Article in English | MEDLINE | ID: mdl-27317915

ABSTRACT

BACKGROUND: Early microcirculatory responses after experimental tenotomy are critical to the healing of tendons and their ultimate tensile strength. The effects of changes in microcirculation on the outcomes of tendon healing, however, have not been determined. OBJECTIVES: To assess microcirculation values in injured Achilles tendons in the first 3 months after surgical repair and to correlate the inter-limb microcirculatory changes with functional outcomes at 3 and 6 months after surgery. DESIGN: Case-control study. SETTING: A university sports physiotherapy laboratory. PARTICIPANTS: Thirteen subjects (median age: 45 years; range: 34.8-51.9 years) with a repaired Achilles tendon were recruited. METHODS OR INTERVENTION: Surgical repair. MAIN OUTCOME MEASUREMENTS: Measurements were obtained at 1, 2, 3, and 6 months after surgery. Bilateral measurements of tendon microcirculation (total hemoglobin [THb] and oxygen saturation [StO2]) were recorded at the first 3 time points, whereas outcome measures of a Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire, one-leg hopping distance, the star excursion balance test, and the heel raise index were conducted at the third and fourth time points. Correlations between the inter-limb microcirculatory changes, eg, between the measurements at 2 months and 1 month (2-1) after surgery, at 3 months and 2 months (3-2) after surgery, and at 3 months and 1 month (3-1) after surgery, and the outcome measures were investigated. RESULTS: Compared with the noninjured tendons, the repaired Achilles demonstrated greater THb (at 1, 2, and 3 months; P = .017, .008, and .012 respectively) and StO2 (at 3 months; P = .017). Furthermore, the THb2-1 and THb3-2, StO2 2-1, and StO2 3-2 showed correlations with the heel raise index, differences in the star excursion balance test and one-leg hopping distance between the noninjured leg and injured leg, and Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire scores (rho -0.921 to 0.855). CONCLUSIONS: Changes in the inter-limb microcirculation shortly after Achilles repair were correlated with subsequent symptoms and functional symmetry. LEVEL OF EVIDENCE: III.


Subject(s)
Achilles Tendon/blood supply , Achilles Tendon/injuries , Tendon Injuries/surgery , Adult , Case-Control Studies , Female , Humans , Male , Microcirculation , Middle Aged , Recovery of Function , Rupture , Treatment Outcome
15.
Ultrason Sonochem ; 32: 44-53, 2016 09.
Article in English | MEDLINE | ID: mdl-27150744

ABSTRACT

The effects of an implant on temperature distribution in a tissue-mimicking hydrogel phantom during the application of therapeutic ultrasound were investigated. In vitro experiments were conducted to compare the influences of plastic and metal implants on ultrasound diathermy and to calibrate parameters in finite element simulation models. The temperature histories and characteristics of the opaque (denatured) areas in the hydrogel phantoms predicted by the numerical simulations show good correlation with those observed in the in vitro experiments. This study provides an insight into the temperature profile in the vicinity of an implant by therapeutic ultrasound heating typically used for physiotherapy. A parametric study was conducted through numerical simulations to investigate the effects of several factors, such as implant material type, ultrasound operation frequency, implant thickness and tissue thickness on the temperature distribution in the hydrogel phantom. The results indicate that the implant material type and implant thickness are the main parameters influencing the temperature distribution. In addition, once the implant material and ultrasound operation frequency are chosen, an optimal implant thickness can be obtained so as to avoid overheating injuries in tissue.


Subject(s)
Temperature , Ultrasonic Therapy , Computer Simulation , Models, Biological , Phantoms, Imaging
16.
J Orthop Res ; 34(2): 240-8, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26222735

ABSTRACT

Osteoporosis and osteoarthritis commonly coexist in the elderly. In patients undergoing prosthetic total knee arthroplasty (TKA), the bone quality around the knee joint may affect the safety of prosthetic implantation and consequently satisfaction with the surgical outcome. We recruited 50 postmenopausal women undergoing TKA for primary osteoarthritis; 43 completed the study protocol. The bone quality parameters of the operated knee, including bone mineral density assessed using dual-energy X-ray absorptiometry and microarchitecture variables assessed using micro-computed tomography, were determined. Surgical outcomes were assessed according to immediate (<1 week) postoperative pain quantified using the visual analog scale and knee function quantified using the Knee Injury and Osteoarthritis Outcome Score (KOOS) at 2 and 6 months postoperatively. The influence of bone quality parameters on surgical outcomes was analyzed using simple and multiple regression analyses. Volumetric bone mineral density (R(2) = 0.187-0.234, p < 0.01), the structural model index (R(2) = 0.103-0.181, p < 0.05), and trabecular separation (R(2) = 0.289-0.424, p < 0.05) were significantly associated with postoperative pain and improvement according to the KOOS. In conclusion, local bone quality, including mineral content and microarchitecture, affects the surgical outcome of TKA.


Subject(s)
Arthroplasty, Replacement, Knee/statistics & numerical data , Bone Density , Osteoarthritis, Knee/surgery , Osteoporosis, Postmenopausal/complications , Aged , Female , Humans , Knee Joint/diagnostic imaging , Knee Prosthesis , Middle Aged , Osteoarthritis, Knee/complications , Pain, Postoperative/epidemiology , Prospective Studies , Radiography , Taiwan/epidemiology , Treatment Outcome
17.
J Orthop Sports Phys Ther ; 45(7): 563-9, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26039223

ABSTRACT

STUDY DESIGN: Controlled laboratory study. OBJECTIVES: To measure Achilles tendon microcirculation (total hemoglobin [THb] and oxygen saturation [StO2]) before and after the application of a physical agent in asymptomatic participants, and to compare differences between application location and physical agent dosage. BACKGROUND: Tendon microcirculation can be altered by superficial heating or cryotherapy. METHODS: Fifty-one healthy adults (median age, 22 years; range, 20-34 years) were recruited and randomly assigned into 1 of 4 groups. Participants in each group received an intervention consisting of 1 of the following 4 physical agents: ultrasound (n = 12), interferential current (n = 14), low-level laser (n = 11), or vibration massage (n = 14). In each group, the selected intervention was applied at 2 different doses (ultrasound, 0.8 or 1.2 W/cm(2); laser, 5.4 or 18 J) or target locations (vibration and electrostimulation, calf muscle or Achilles tendon). For each participant, each dose or target location was randomly applied to 1 randomly selected lower leg (each leg receiving only 1 of the 2 options). RESULTS: The StO2 values significantly increased after ultrasound at both doses (P<.008), and the THb value significantly increased for the higher dose only (P<.008). Both THb and StO2 values also significantly increased in response to vibration massage targeting the Achilles tendon (P<.008), and these values were greater than those resulting from the vibration massage applied to the calf muscle (P = .003 and .002, respectively). No significant THb and StO2 differences were found after the application of interferential current or low-level laser. CONCLUSION: Tendon microcirculation increases after ultrasound and vibration massage intervention concentrated on the Achilles tendon. These modalities may be considered for the purpose of temporarily increasing microcirculation in the tendon.


Subject(s)
Achilles Tendon/blood supply , Electric Stimulation Therapy , Low-Level Light Therapy , Microcirculation/radiation effects , Ultrasonic Therapy , Vibration , Adult , Female , Healthy Volunteers , Humans , Male , Random Allocation , Young Adult
18.
Arch Phys Med Rehabil ; 94(8): 1590-8, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23380346

ABSTRACT

OBJECTIVES: To compare the neuromechanical and functional characteristics of the legs of athletes who underwent unilateral Achilles' tendon repair and their controls, and to determine any correlation between the characteristics. DESIGN: A case-control and cross-sectional study. SETTING: A university institute. PARTICIPANTS: Male athletes (N=33) were recruited; 23 in the ≥3- and <12-month postsurgical group (median age, 29.8y; age range, 21.9-40.0y) and 10 in the control group (median age, 30.0y; age range, 21.1-39.5y) who had not undergone any surgery. INTERVENTION: Surgical Achilles' tendon repair in the study group. MAIN OUTCOME MEASURES: Bilateral measurements of activation strategy involving the triceps surae and tibialis anterior muscles, mechanical properties of the Achilles' tendon, and explosive performance tests were conducted. RESULTS: Compared with the noninjured legs and the control legs, the repaired legs showed lower normalized rates of electromyographic rise (RER) in the soleus, gastrocnemius medialis, and gastrocnemius lateralis (P ranged between .006 and .001); and less tendon stiffness, greater hysteresis, and less rates of force development (RFD) (P ranged between .006 and <.001). Repaired legs had less ankle dorsiflexion, a shorter 1-leg hopping distance, and lower balance scores (P≤.001). The noninjured legs of the athletes who underwent surgical Achilles' tendon repair had a lower normalized RER (0-50 ms) in the soleus and lateral gastrocnemius when compared with the legs of the healthy controls (P=.011). The neuromechanical outcomes and explosive performances showed correlations with RFD, 1-leg hopping distance, and balance score. CONCLUSIONS: The athletes who underwent unilateral Achilles' tendon repair demonstrated bilateral neuromechanical deficits within the 1-year postsurgical period.


Subject(s)
Achilles Tendon/injuries , Achilles Tendon/physiopathology , Athletic Injuries/surgery , Muscle, Skeletal/physiopathology , Muscle, Skeletal/transplantation , Adult , Athletic Injuries/physiopathology , Athletic Injuries/rehabilitation , Case-Control Studies , Cross-Sectional Studies , Electromyography , Humans , Male , Muscle Contraction/physiology , Range of Motion, Articular , Recovery of Function/physiology , Rupture , Time Factors , Treatment Outcome , Young Adult
19.
J Formos Med Assoc ; 111(12): 698-704, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23265749

ABSTRACT

BACKGROUND/PURPOSE: Quadriceps-sparing minimally invasive total knee arthroplasty (TKA) has been proposed to limit surgical dissection without compromising surgical outcome. We conducted a prospective and randomized study to compare the outcomes of patients who underwent quadriceps-sparing TKA with the outcomes of those who underwent standard medial parapatellar TKA, after a 2-year follow-up period. METHODS: Eighty primary TKA procedures that were to be performed in 60 osteoarthritis patients were randomly assigned to either a quadriceps-sparing (40 knees) or a standard medial parapatellar (40 knees) group. All surgeries were designed to set the prosthesis with a femoral component alignment of 7° valgus and a tibial component alignment that was perpendicular to the tibial shaft. Surgical time and tourniquet time were recorded. Outcome variables included knee function, as defined by a hospital for special surgery knee score; quadriceps muscle strength, which was measured by an isokinetic dynamometer; pain, as indicated on a visual analog scale; prosthetic position, which was measured on plain radiograph; and range of motion. RESULTS: Patients who underwent the 38 quadriceps-sparing and 37 standard TKA procedures completed the 2-year follow-up period without any infection or revision. The mean surgical time and tourniquet time were significantly longer in the quadriceps-sparing group. The mean peak quadriceps muscle strength, hamstring muscle strength, normalized muscle balance (hamstring/quadriceps ratio), pain score, function score, and range of motion were comparable in both groups at 2 months and 2 years. In the quadriceps-sparing group, both the femoral and the tibial components were significantly more varus-deviated from the expected position. CONCLUSIONS: Patients undergoing quadriceps-sparing and standard medial parapatellar TKA had comparable outcomes for quadriceps muscle strength, hamstring-quadriceps balance, and knee function; however, the quadriceps-sparing TKA was more time consuming surgically and resulted in a less accurate prosthesis position.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Quadriceps Muscle/surgery , Aged , Arthroplasty, Replacement, Knee/adverse effects , Female , Follow-Up Studies , Humans , Knee Joint/physiology , Male , Middle Aged , Muscle Strength , Operative Time , Organ Sparing Treatments , Pain, Postoperative/etiology , Quadriceps Muscle/physiology , Range of Motion, Articular
20.
Tissue Eng Part A ; 17(23-24): 2919-29, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21895487

ABSTRACT

Implantation of autologous chondrogenic cells has become the mainstay strategy for repairing articular cartilage defects. Because the availability of autologous chondrocytes is extremely limited, many recent studies have used artificially induced mesenchymal stem cells (iMSCs) as substitutes for chondrocytes. In this study, we analyzed the differences between the iMSCs and chondrocytes, including their molecular biological and mechanical properties. Human bone marrow-derived MSCs were collected and induced to exhibit the chondrogenic phenotype by culturing the pelleted MSCs in a chemically defined culture medium supplemented with transforming growth factor-beta 1. The molecular biological properties of iMSCs and culture-expanded chondrocytes, including their mRNA profiles and surface proteomics, were analyzed using reverse transcription-polymerase chain reaction (RT-PCR) and flow cytometry, respectively. The biomechanical properties of iMSCs and native chondrocytes, including their surface topology, adhesion force, and membrane stiffness, were analyzed using atomic force microscopy (AFM). Both iMSCs and chondrocytes presented type II collagen and glycosaminoglycan, whereas only chondrocytes presented type X collagen. Flow cytometric assays showed that the expression of type II collagen and integrin-1 was higher in the chondrocytes than in the iMSCs. AFM revealed that the MSCs, iMSCs, and chondrocytes greatly differed in their shape. The MSCs were spindle shaped and easily distinguishable from the spherical chondrocytes. The iMSCs appeared round and resembled the spherical chondrocytes; however, the iMSCs were flatter with a central hump of condensed mass and a surrounding thin and broad pleat. The mean adhesion force and mean surface stiffness were significantly lower for the iMSCs (4.54 nN and 0.109 N/m, respectively) than for the chondrocytes (6.86 nN and 0.134 N/m, respectively). To conclude, although the iMSCs exhibited the chondrogenic phenotype, they differed from the chondrocytes in their molecular biological and mechanical properties.


Subject(s)
Bone Marrow Cells/cytology , Chondrocytes/cytology , Chondrogenesis , Adult , Aged , Biomarkers/metabolism , Biomechanical Phenomena/genetics , Bone Marrow Cells/metabolism , Cell Adhesion , Cell Differentiation/genetics , Chondrocytes/metabolism , Chondrogenesis/genetics , Collagen/genetics , Collagen/metabolism , Female , Flow Cytometry , Gene Expression Regulation , Humans , Immunohistochemistry , Male , Microscopy, Atomic Force , Middle Aged , RNA, Messenger/genetics , RNA, Messenger/metabolism , Reverse Transcriptase Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...