Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Transplant Cell Ther ; 27(12): 1022.e1-1022.e6, 2021 12.
Article in English | MEDLINE | ID: mdl-34571211

ABSTRACT

Changes to donor availability, collection center capacity, and travel restrictions during the early phase of the COVID-19 pandemic led to routine cryopreservation of most unrelated donor products for hematopoietic transplantation prior to the recipient commencing the conditioning regimen. We investigated the effect of this change on unrelated donor product quality and clinical outcomes. Product information was requested from transplantation centers in Australia and New Zealand and clinical outcome data from the Australasian Bone Marrow Transplant Recipient Registry (ABMTRR). In total, 191 products were collected between April 1, 2021, and September 30, 2021, and most (74%) were from international collection centers. Median post-thaw CD34 recovery was 78% (range 25% to 176%) and median post-thaw CD34 viability was 87% (range 34% to 112%). Median time to neutrophil recovery was 17 days (interquartile range 10 to 24 days), and graft failure occurred in 6 patients (4%). These clinical outcomes were similar to those of "fresh" unrelated donor transplants reported to the ABMTRR in 2019. However, recipient transplantation centers reported problems with 29% of products in the form of damage during transit, low cell dose, inadequate labeling, missing representative samples, or missing documentation. These problems were critical in 7 cases (4%). At last follow-up, 22 products (12%) had not been infused. Routine cryopreservation of unrelated donor hemopoietic progenitor cell products has enabled safe continuation of allogeneic transplant services during the COVID-19 pandemic. However, practices for product tracing, documentation, and transportation can be optimized, and measures to reduce the incidence of unused unrelated donor product are required.


Subject(s)
COVID-19 , Cryopreservation , Hematopoietic Stem Cells , Humans , Pandemics , SARS-CoV-2
2.
Blood Adv ; 4(17): 4147-4150, 2020 09 08.
Article in English | MEDLINE | ID: mdl-32886750

ABSTRACT

Donor registries and transplantation societies recommend cryopreservation of unrelated donor hemopoietic progenitor cell (HPC) products before the recipient commences conditioning therapy to mitigate the donor and travel risks associated with the COVID-19 pandemic. However, little is known regarding the postthaw quality of such allogeneic products or the effect of precryopreservation storage and processing on these characteristics. We investigated the postthaw CD34+ cell recovery and viability of 305 allogeneic HPC products cryopreserved at 9 laboratories across Australia. Median postthaw CD34+ cell recovery was 76% and ranged from 6% to 122%. Longer transit time before cryopreservation, white cell count (WCC) during storage, and complex product manipulation before cryopreservation were independently associated with inferior postthaw CD34+ cell recovery. Longer precryopreservation transit time and WCC were also associated with inferior postthaw CD34+ cell viability. We conclude that although postthaw CD34+ cell recovery and viability of cryopreserved allogeneic HPC is generally acceptable, there is a significant risk of poor postthaw product quality, associated with prolonged storage time, higher WCC, and complex product manipulation precryopreservation. Awareness of expected postthaw recovery and practices that influence it will assist collection, processing, and transplant centers in optimizing outcomes for transplant recipients.


Subject(s)
Antigens, CD34/analysis , Cryopreservation , Hematopoietic Stem Cells/cytology , COVID-19 , Cell Survival , Coronavirus Infections/epidemiology , Hematopoietic Stem Cell Transplantation , Humans , Pandemics , Pneumonia, Viral/epidemiology , Transplantation, Homologous
3.
J Transplant ; 2013: 163150, 2013.
Article in English | MEDLINE | ID: mdl-24163756

ABSTRACT

A survey of 24 international heart valve banks was conducted to acquire information on heart valve processing techniques used and outcomes achieved. The objective was to provide an overview of heart valve banking activities for tissue bankers, tissue banking associations, and regulatory bodies worldwide. Despite similarities found for basic manufacturing processes, distinct differences in procedural details were also identified. The similarities included (1) use of sterile culture media for procedures, (2) antibiotic decontamination, (3) use of dimethyl sulfoxide (DMSO) as a cryoprotectant, (4) controlled rate freezing for cryopreservation, and (5) storage at ultralow temperatures of below -135°C. Differences in procedures included (1) type of sterile media used, (2) antibiotics combination, (3) temperature and duration used for bioburden reduction, (4) concentration of DMSO used for cryopreservation, and (5) storage duration for released allografts. For most banks, the primary reasons why allografts failed to meet release criteria were positive microbiological culture and abnormal morphology. On average, 85% of allografts meeting release criteria were implanted, with valve size and type being the main reasons why released allografts were not used clinically. The wide variation in percentage of allografts meeting release requirements, despite undergoing validated manufacturing procedures, justifies the need for regular review of important outcomes as cited in this paper, in order to encourage comparison and improvements in the HVBs' processes.

SELECTION OF CITATIONS
SEARCH DETAIL
...