Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
Dev Biol ; 457(1): 30-42, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31520602

ABSTRACT

In early vertebrate embryos, the dorsal ectoderm is induced by the axial mesendoderm to form the neural plate, which is given competence to form neural cells by soxB1 genes. Subsequently, neurogenesis proceeds in proneural clusters that are generated by a gene network involving proneural genes and Notch signaling. However, what occurs between early neural induction and the later initiation of neurogenesis has not been fully revealed. In the present study, we demonstrated that during gastrulation, the expression of the Oct4-related PouV gene pou5f3 (also called pou2), which is widely observed at earlier stages, was rapidly localized to an array of isolated spotted domains, each of which coincided with individual proneural clusters. Two-color in situ hybridization confirmed that each pou5f3-expressing domain included a proneural cluster. Further analysis demonstrated that anterior pou5f3 domains straddled the boundaries between rhombomere 1 (r1) and r2, whereas posterior domains were included in r4. The effects of forced expression of an inducible negative dominant-interfering pou5f3 gene suggested that pou5f3 activated early proneural genes, such as neurog1 and ebf2, and also soxB1, but repressed the late proneural genes atoh1a and ascl1b. Furthermore, pou5f3 was considered to repress her4.1, a Notch-dependent Hairy/E(spl) gene involved in lateral inhibition in proneural clusters. These results suggest that pou5f3 promotes early neurogenesis in proneural clusters, but negatively regulates later neurogenesis. Suppression of pou5f3 also altered the expression of other her genes, including her3, her5, and her9, further supporting a role for pou5f3 in neurogenesis. In vitro reporter assays in P19 cells showed that pou5f3 was repressed by neurog1, but activated by Notch signaling. These findings together demonstrate the importance of the pou5f3-mediated gene regulatory network in neural development in vertebrate embryos.


Subject(s)
Neural Plate/embryology , Neurogenesis , Octamer Transcription Factor-3/metabolism , Zebrafish Proteins/metabolism , Zebrafish/embryology , Animals , Body Patterning , Embryo, Nonmammalian/metabolism , Embryonic Development , Neural Plate/metabolism , Octamer Transcription Factor-3/genetics , SOXB1 Transcription Factors/genetics , Zebrafish Proteins/genetics
2.
J Radiat Res ; 58(5): 720-728, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28595311

ABSTRACT

We evaluated dose-volume histogram (DVH) parameters based on deformable image registration (DIR) between brachytherapy (BT) and external beam radiotherapy (EBRT) that included a center-shielded (CS) plan. Eleven cervical cancer patients were treated with BT, and their pelvic and CS EBRT were studied. Planning CT images for EBRT and BT (except for the first BT, used as the reference image) were deformed with DIR to reference image. We used two DIR parameter settings: intensity-based and hybrid. Mean Dice similarity coefficients (DSCs) comparing EBRT with the reference for the uterus, rectum and bladder were 0.81, 0.77 and 0.83, respectively, for hybrid DIR and 0.47, 0.37 and 0.42, respectively, for intensity-based DIR (P < 0.05). D1 cm3 for hybrid DIR, intensity-based DIR and DVH addition were 75.1, 81.2 and 78.2 Gy, respectively, for the rectum, whereas they were 93.5, 92.3 and 94.3 Gy, respectively, for the bladder. D2 cm3 for hybrid DIR, intensity-based DIR and DVH addition were 70.1, 74.0 and 71.4 Gy, respectively, for the rectum, whereas they were 85.4, 82.8 and 85.4 Gy, respectively, for the bladder. Overall, hybrid DIR obtained higher DSCs than intensity-based DIR, and there were moderate differences in DVH parameters between the two DIR methods, although the results varied among patients. DIR is only experimental, and extra care should be taken when comparing DIR-based dose values with dose-effect curves established using DVH addition. Also, a true evaluation of DIR-based dose accumulation would require ground truth data (e.g. measurement with physical phantom).


Subject(s)
Brachytherapy , Radiographic Image Interpretation, Computer-Assisted , Rectum/radiation effects , Urinary Bladder/radiation effects , Uterine Cervical Neoplasms/radiotherapy , Apoptosis/radiation effects , Dose-Response Relationship, Radiation , Female , Hardness , Humans , Photons
3.
J Radiat Res ; 58(4): 567-571, 2017 Jul 01.
Article in English | MEDLINE | ID: mdl-28158642

ABSTRACT

This study aimed to evaluate the performance of the hybrid deformable image registration (DIR) method in comparison with intensity-based DIR for pelvic cone-beam computed tomography (CBCT) images, using intensity and anatomical information. Ten prostate cancer patients treated with intensity-modulated radiation therapy (IMRT) were studied. Nine or ten CBCT scans were performed for each patient. First, rigid registration was performed between the planning CT and all CBCT images using gold fiducial markers, and then DIR was performed. The Dice similarity coefficient (DSC) and center of mass (COM) displacement were used to evaluate the quantitative DIR accuracy. The average DSCs for intensity-based DIR for the prostate, rectum, bladder, and seminal vesicles were 0.84 ± 0.05, 0.75 ± 0.05, 0.69 ± 0.07 and 0.65 ± 0.11, respectively, whereas those values for hybrid DIR were 0.98 ± 0.00, 0.97 ± 0.01, 0.98 ± 0.00 and 0.94 ± 0.03, respectively (P < 0.05). The average COM displacements for intensity-based DIR for the prostate, rectum, bladder, and seminal vesicles were 2.0 ± 1.5, 3.7 ± 1.4, 7.8 ± 2.2 and 3.6 ± 1.2 mm, whereas those values for hybrid DIR were 0.1 ± 0.0, 0.3 ± 0.2, 0.2 ± 0.1 and 0.6 ± 0.6 mm, respectively (P < 0.05). These results showed that the DSC for hybrid DIR had a higher DSC value and smaller COM displacement for all structures and all patients, compared with intensity-based DIR. Thus, the accumulative dose based on hybrid DIR might be trusted as a high-precision dose estimation method that takes into account organ movement during treatment radiotherapy.


Subject(s)
Cone-Beam Computed Tomography , Pelvis/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted , Radiotherapy Planning, Computer-Assisted , Humans , Male , Prostatic Neoplasms/radiotherapy , Rectum/diagnostic imaging , Urinary Bladder/diagnostic imaging
4.
Med Phys ; 44(4): 1445-1455, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28214368

ABSTRACT

PURPOSE: In this study, we developed a 3D-printed deformable pelvis phantom for evaluating spatial DIR accuracy. We then evaluated the spatial DIR accuracies of various DIR settings for cervical cancer. METHODS: A deformable female pelvis phantom was created based on patient CT data using 3D printing. To create the deformable uterus phantom, we first 3D printed both a model of uterus and a model of the internal cavities of the vagina and uterus. We then made a mold using the 3D printed uterus phantom. Finally, urethane was poured into the mold with the model of the internal cavities in place, creating the deformable uterus phantom with a cavity into which an applicator could be inserted. To create the deformable bladder phantom, we first 3D printed models of the bladder and of the same bladder scaled down by 2 mm. We then made a mold using the larger bladder model. Finally, silicone was poured into the mold with the smaller bladder model in place to create the deformable bladder phantom with a wall thickness of 2 mm. To emulate the anatomical bladder, water was poured into the created bladder. We acquired phantom image without applicator for EBRT. Then, we inserted the applicator into the phantom to simulate BT. In this situation, we scanned the phantom again to obtain the phantom image for BT. We performed DIR using the two phantom images in two cases: Case A, with full bladder (170 ml) in both EBRT and BT images; and Case B with full bladder in the BT image and half-full bladder (100 ml) in the EBRT image. DIR was evaluated using Dice similarity coefficients (DSCs) and 31 landmarks for the uterus and 25 landmarks for the bladder. A hybrid intensity and structure DIR algorithm implemented in RayStation with four DIR settings was evaluated. RESULTS: On visual inspection, reasonable agreement in shape of the uterus between the phantom and patient CT images was observed for both EBRT and BT, although some regional disagreements in shape of the bladder and rectum were apparent. The created phantom could reproduce the actual patient's uterus deformation by the applicator. For both Case A and B, large variation was seen in landmark error among the four DIR parameters. In addition, although DSCs were comparable, moderate differences in landmark error existed between the two different DIR parameters selected from the four DIR parameters (i.e., DSC = 0.96, landmark error = 13.2 ± 5.7 mm vs. DSC = 0.97, landmark error = 9.7 ± 4.0 mm). This result suggests that landmark error evaluation might thus be more effective than DSC for evaluating DIR accuracy. CONCLUSIONS: Our developed phantom enabled the evaluation of spatial DIR accuracy for the female pelvic region for the first time. Although the DSCs are high, the spatial errors can still be significant and our developed phantom facilitates their quantification. Our results showed that optimization is needed to identify suitable DIR settings. For determining suitable DIR settings, our method of evaluating spatial DIR accuracy using the 3D-printed phantom may prove helpful.


Subject(s)
Brachytherapy , Image Processing, Computer-Assisted/instrumentation , Pelvis/diagnostic imaging , Phantoms, Imaging , Printing, Three-Dimensional , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Radiotherapy Dosage , Tomography, X-Ray Computed
5.
Article in Japanese | MEDLINE | ID: mdl-28111399

ABSTRACT

Our aim was to investigate the feasibility of a three-dimensional (3D) -printed head-and-neck (HN) immobilization device by comparing its positional accuracy and dosimetric properties with those of a conventional immobilization device (CID). We prepared a 3D-printed immobilization device (3DID) consisting of a mask and headrest with acrylonitrile-butadiene-styrene resin developed from the computed tomography data obtained by imaging a HN phantom. For comparison, a CID comprising a thermoplastic mask and headrest was prepared using the same HN phantom. We measured the setup error using the ExacTrac X-ray image system. Furthermore, using the ionization chamber and the water-equivalent phantom, we measured the changes in the dose due to the difference in the immobilization device material from the photon of 4 MV and 6 MV. The positional accuracy of the two devices were almost similar in each direction except in the vertical, lateral, and pitch directions (t-test, p<0.0001), and the maximum difference was 1 mm, and 1°. The standard deviations were not statistically different in each direction except in the longitudinal (F-test, p=0.034) and roll directions (F-test, p<0.0001). When the thickness was the same, the dose difference was almost similar at a 50 mm depth. At a 1 mm depth, the 3DID-plate had a 2.9-4.2% lower dose than the CID-plate. This study suggested that the positional accuracy and dosimetric properties of 3DID were almost similar to those of CID.


Subject(s)
Head/diagnostic imaging , Neck/diagnostic imaging , Patient Positioning , Printing, Three-Dimensional , Radiotherapy Planning, Computer-Assisted/methods , Humans , Printing, Three-Dimensional/instrumentation , Radiometry , Radiotherapy Planning, Computer-Assisted/instrumentation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...