1.
Environ Eng Sci ; 30(6): 324-332, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23781129

ABSTRACT

Recent studies have shown that treated municipal wastewater can be a reliable cooling water alternative to fresh water. However, elevated nutrient concentration and microbial population in wastewater lead to aggressive biological proliferation in the cooling system. Three chlorine-based biocides were evaluated for the control of biological growth in cooling systems using tertiary treated wastewater as makeup, based on their biocidal efficiency and cost-effectiveness. Optimal chemical regimens for achieving successful biological growth control were elucidated based on batch-, bench-, and pilot-scale experiments. Biocide usage and biological activity in planktonic and sessile phases were carefully monitored to understand biological growth potential and biocidal efficiency of the three disinfectants in this particular environment. Water parameters, such as temperature, cycles of concentration, and ammonia concentration in recirculating water, critically affected the biocide performance in recirculating cooling systems. Bench-scale recirculating tests were shown to adequately predict the biocide residual required for a pilot-scale cooling system. Optimal residuals needed for proper biological growth control were 1, 2-3, and 0.5-1 mg/L as Cl2 for NaOCl, preformed NH2Cl, and ClO2, respectively. Pilot-scale tests also revealed that Legionella pneumophila was absent from these cooling systems when using the disinfectants evaluated in this study. Cost analysis showed that NaOCl is the most cost-effective for controlling biological growth in power plant recirculating cooling systems using tertiary-treated wastewater as makeup.

2.
Water Res ; 46(19): 6508-18, 2012 Dec 01.
Article in English | MEDLINE | ID: mdl-23063442

ABSTRACT

Secondary-treated municipal wastewater, an abundant and widely distributed impaired water source, is a promising alternative water source for thermoelectric power plant cooling. However, excessive biological growth is a major challenge associated with wastewater reuse in cooling systems as it can interfere with normal system operation as well as enhance corrosion and scaling problems. Furthermore, possible emission of biological aerosols (e.g., Legionella pneumophila) with the cooling tower drift can lead to public health concerns within the zone of aerosol deposition. In this study, the effectiveness of pre-formed and in-situ-formed monochloramine was evaluated for its ability to control biological growth in recirculating cooling systems using secondary-treated municipal wastewater as the only makeup water source. Bench-scale studies were compared with pilot-scale studies for their ability to predict system behavior under realistic process conditions. Effectiveness of the continuous addition of pre-formed monochloramine and monochloramine formed in-situ through the reaction of free chlorine with ammonia in the incoming water was evaluated in terms of biocide residual and its ability to control both planktonic and sessile microbial populations. Results revealed that monochloramine can effectively control biofouling in cooling systems employing secondary-treated municipal wastewater and has advantages relative to use of free chlorine, but that bench-scale studies seriously underestimate biocide dose and residual requirements for proper control of biological growth in full-scale systems. Pre-formed monochloramine offered longer residence time and more reliable performance than in-situ-formed monochloramine due to highly variable ammonia concentration in the recirculating water caused by ammonia stripping in the cooling tower. Pilot-scale tests revealed that much lower dosing rate was required to maintain similar total chlorine residual when pre-formed monochloramine was used as compared to in-situ-formed monochloramine. Adjustment of biocide dose to maintain monochloramine residual above 3mg/L is needed to achieve successful biological growth control in recirculating cooling systems using secondary-treated municipal effluent as the only source of makeup water.


Subject(s)
Biofouling/prevention & control , Chloramines/chemistry , Chloramines/pharmacology , Power Plants/instrumentation , Wastewater/microbiology , Water Purification/methods , Ammonia/chemistry , Bacteria/drug effects , Bacteria/growth & development , Chlorine/chemistry , Disinfectants/pharmacology , Disinfection/methods , Equipment Design , Legionella pneumophila/drug effects , Legionella pneumophila/growth & development , Pilot Projects
3.
Water Res ; 46(14): 4488-98, 2012 Sep 15.
Article in English | MEDLINE | ID: mdl-22727862

ABSTRACT

Treated municipal wastewater (MWW) is recognized as a significant potential source of cooling water for power generation. One of the key challenges for the successful use of the effluent from wastewater treatment facilities for cooling is the potential for significant mineral scaling when the raw water is concentrated as much as 4-6 times in recirculating cooling systems. Previous bench- and pilot-scale tests have shown that commonly used phosphorus- and polymer- based scaling inhibitors are ineffective when secondary-treated municipal wastewater (MWW) is used as make-up. In this study, two types of tertiary-treated municipal wastewaters, namely secondary-treated MWW with pH adjustment (MWW_pH) and secondary-treated MWW subjected to nitrification and sand filtration (MWW_NF) were evaluated as the sole source of make-up water for recirculating cooling systems. Both laboratory studies and pilot-scale tests revealed that adjusting the pH to 7.8 could reduce the mineral scaling rate by more than 80% without causing any significant corrosion problems. In contrast to MWW, where calcium carbonate was the dominant scaling mineral, the main component of mineral scale in MWW_pH was calcium phosphate. Both static and dynamic bench-scale tests indicated that scaling would not be a significant concern when MWW_NF is used as the make-up water in recirculating cooling systems operated at 4-6 cycles of concentration (CoC). Extended pilot-scale studies confirmed that MWW_NF is suitable makeup water for power plant cooling systems and that no anti-scaling chemicals would be required.


Subject(s)
Cities , Cold Temperature , Minerals/chemistry , Waste Disposal, Fluid , Water Purification/methods , Batch Cell Culture Techniques , Calcium/analysis , Chemical Precipitation , Hydrogen-Ion Concentration , Microscopy, Electron, Scanning , Pennsylvania , Phosphates/analysis , Pilot Projects , Solutions , X-Ray Diffraction
4.
Water Environ Res ; 83(9): 807-14, 2011 Sep.
Article in English | MEDLINE | ID: mdl-22073728

ABSTRACT

Passively treated abandoned mine drainage (AMD) is a promising alternative to fresh water as power plant cooling water system makeup water in mining regions where such water is abundant. Passive treatment and reuse of AMD can avoid the contamination of surface water caused by discharge of abandoned mine water, which typically is acidic and contains high concentrations of metals, especially iron. The purpose of this study was to evaluate the feasibility of reusing passively treated AMD in cooling systems with respect to corrosion control through laboratory experiments and pilot-scale field testing. The results showed that, with the addition of the inhibitor mixture orthophosphate and tolyltriazole, mild steel and copper corrosion rates were reduced to acceptable levels (< 0.127 mm/y and < 0.0076 mm/y, respectively). Aluminum had pitting corrosion problems in every condition tested, while cupronickel showed that, even in the absence of any inhibitor and in the presence of the biocide monochloramine, its corrosion rate was still very low (0.018 mm/y).


Subject(s)
Corrosion , Industrial Waste , Mining , Power Plants , Water , Pilot Projects
5.
Environ Sci Technol ; 45(10): 4195-200, 2011 May 15.
Article in English | MEDLINE | ID: mdl-21466187

ABSTRACT

To ensure sufficient thermoelectric power production in the future, the use of alternative water sources to replace freshwater consumption in power plants will be required. The amount of municipal wastewater (MWW) being produced and its widespread availability merit the investigation of this potential source of cooling water. This is particularly important for thermoelectric power plants in regions where freshwater is not readily available. Critical regulatory and technical challenges for using MWW as makeup water in recirculating cooling systems are examined. The existing regulations do not prohibit wastewater reuse for power plant cooling. The challenges of controlling corrosion, mineral scaling, and biofouling in recirculating cooling systems need to be carefully considered and balanced in a holistic fashion. Initial investigations suggest that many of these challenges can be surmounted to ensure the use of MWW in recirculating cooling systems.


Subject(s)
Power Plants/statistics & numerical data , Waste Disposal, Fluid/methods , Water Supply/statistics & numerical data , Conservation of Natural Resources/methods
6.
Water Res ; 45(2): 748-60, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20851443

ABSTRACT

Secondary-treated municipal wastewater (MWW) is a promising alternative to freshwater as power plant cooling system makeup water, especially in arid regions. A prominent challenge for the successful use of MWW for cooling is potentially severe mineral deposition (scaling) on pipe surfaces. In this study, theoretical, laboratory, and field work was conducted to evaluate the mineral deposition potential of MWW and its deposition control strategies under conditions relevant to power plant cooling systems. Polymaleic acid (PMA) was found to effectively reduce scale formation when the makeup water was concentrated four times in a recirculating cooling system. It was the most effective deposition inhibitor of those studied when applied at 10 mg/L dosing level in a synthetic MWW. However, the deposition inhibition by PMA was compromised by free chlorine added for biogrowth control. Ammonia present in the wastewater suppressed the reaction of the free chlorine with PMA through the formation of chloramines. Monochloramine, an alternative to free chlorine, was found to be less reactive with PMA than free chlorine. In pilot tests, scaling control was more challenging due to the occurrence of biofouling even with effective control of suspended bacteria. Phosphorous-based corrosion inhibitors are not appropriate due to their significant loss through precipitation reactions with calcium. Chemical equilibrium modeling helped with interpretation of mineral precipitation behavior but must be used with caution for recirculating cooling systems, especially with use of MWW, where kinetic limitations and complex water chemistries often prevail.


Subject(s)
Chemical Precipitation/drug effects , Polyesters/pharmacology , Power Plants , Waste Disposal, Fluid , Ammonia/pharmacology , Bioreactors , Chlorine/pharmacology , Organophosphorus Compounds , Phosphates/pharmacology , Pilot Projects , Solubility/drug effects , Water Purification
7.
Water Environ Res ; 82(12): 2346-56, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21214028

ABSTRACT

Secondary treated municipal wastewater is a promising alternative to fresh water as power plant cooling water system makeup water, especially in arid regions. Laboratory and field testing was conducted in this study to evaluate the corrosiveness of secondary treated municipal wastewater for various metals and metal alloys in cooling systems. Different corrosion control strategies were evaluated based on varied chemical treatment. Orthophosphate, which is abundant in secondary treated municipal wastewater, contributed to more than 80% precipitative removal of phosphorous-based corrosion inhibitors. Tolyltriazole worked effectively to reduce corrosion of copper (greater than 95% inhibition effectiveness). The corrosion rate of mild steel in the presence of free chlorine 1 mg/L (as Cl2) was approximately 50% higher than in the presence of monochloramine 1 mg/L (as Cl2), indicating that monochloramine is a less corrosive biocide than free chlorine. The scaling layers observed on the metal alloys contributed to corrosion inhibition, which could be seen by comparing the mild steel 21-day average corrosion rate with the last 5-day average corrosion rate, the latter being approximately 50% lower than the former.


Subject(s)
Waste Disposal, Fluid/methods , Water/chemistry , Corrosion , Electrochemical Techniques