1.
Int J Artif Organs ; 41(7): 385-392, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29749291

ABSTRACT

OBJECTIVES: Mechanical circulatory support for pediatric heart failure patients with the Berlin Heart EXCOR ventricular assist system is the only approved and established bridging strategy for recovery or heart transplantation. In recent years, the burden of thromboembolic events has led to modifications of the recommended antithrombotic therapy. Therefore, we aimed to assess modifications of antithrombotic practice among the European EXCOR Pediatric Investigator Group members. METHODS: We sent a questionnaire assessing seven aspects of antithrombotic therapy to 18 European hospitals using the EXCOR device for children. Returned questionnaires were analyzed and identified antithrombotic strategies were descriptively compared to "Edmonton protocol" recommendations developed for the US EXCOR pediatric approval study. RESULTS: Analysis of 18 received surveys revealed substantial deviations from the Edmonton protocol, including earlier start of heparin therapy at 6-12 h postoperatively and in 50% of surveyed centers, monitoring of heparin effectiveness with aPTT assay, administering vitamin K antagonists before 12 months of age. About 39% of centers use higher international normalized ratio targets, and platelet inhibition is changed in 56% including the use of clopidogrel instead of dipyridamole. Significant inter-center variability with multiple deviations from the Edmonton protocol was discovered with only one center following the Edmonton protocol completely. CONCLUSION: Current antithrombotic practice among European EXCOR users representing the treatment of more than 600 pediatric patients has changed over time with a trend toward a more aggressive therapy. There is a need for systematic evidence-based evaluation and harmonization of developmentally adjusted antithrombotic management practices in prospective studies toward revised recommendations.


Subject(s)
Fibrinolytic Agents/therapeutic use , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Thrombosis/prevention & control , Adolescent , Child , Child, Preschool , Female , Health Care Surveys , Heart Failure/physiopathology , Humans , Infant , Infant, Newborn , Male , Prospective Studies , Thrombosis/etiology , Treatment Outcome , Young Adult
2.
Eur J Cardiothorac Surg ; 51(4): 709-714, 2017 04 01.
Article in English | MEDLINE | ID: mdl-28329112

ABSTRACT

Objectives: With the scarcity of organs, a durable, reliable ventricular assist device (VAD) is required. The Berlin Heart EXCOR ® (BH) remains the most established VAD in the paediatric population. Implantable continuous flow (CF) VADs have been introduced to the paediatric field with encouraging early results. In this study, we compared the results of a newly introduced CF VAD (HeartWare VAD [HVAD] ® ) to results in a matched group of BH recipients. Methods: The study included patients aged <16 years who received mechanical left VAD (LVAD) support between December 2005 and January 2016. The preimplant characteristics and postimplant outcomes of patients who received the HVAD were compared with those of a matched group who received the BH. Patients with congenital heart disease were excluded. Results: Thirty patients were included in the study: 13 had received the HVAD and were matched with 17 patients who had received the BH LVAD. The only difference in preimplant characteristics was the need for higher inotropic support in the BH group. There was no difference in the need for right ventricular (RV) support (58.8% for BH vs 53.8% for HVAD, P = 1.00) or in the incidence of cerebrovascular accidents (12.5% vs 7.7%, respectively, P = 1.00), though the BH group showed prolonged mechanical ventilation (31.3% vs 0%, P = 0.047). There were no deaths while on VAD support in either group. Patients with the HVAD showed a bimodal distribution for the primary end point (transplant/explant): All HVAD recipients who also required early RV support reached this end point within 30 days of receiving the implant. Conclusions: Our early experience with the CF intracorporeal LVAD system (HVAD) indicates outcomes comparable to those with the well-established pulsatile flow paracorporeal LVAD (BH). The theoretical durability of the CF device, which might also allow for the possibility of hospital discharge and better quality of life, is yet to be proven.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices , Adolescent , Child , Child, Preschool , Female , Follow-Up Studies , Heart Transplantation , Heart-Assist Devices/adverse effects , Humans , Male , Prosthesis Design , Prosthesis Failure , Pulsatile Flow , Retrospective Studies , Stroke/etiology , Treatment Outcome
SELECTION OF CITATIONS