Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
EuroIntervention ; 10(1): 169-72, 2014 May.
Article in English | MEDLINE | ID: mdl-24602835

ABSTRACT

BACKGROUND: An 84-year-old man suffering from dyspnoea on mild exertion and a 10-year history of mitral valve replacement with a mechanical prosthesis presented to our department. The patient had an isolated right aortic arch. INVESTIGATION: Transthoracic echocardiography demonstrated severe LV systolic dysfunction (EF 25%), good function of the previously implanted mechanical prosthesis and severe aortic stenosis. Multislice computed tomography confirmed the presence of an isolated right aortic arch with mirror-image branching. DIAGNOSIS: Severe symptomatic aortic stenosis in a patient with right aortic arch at high risk for surgical reintervention. MANAGEMENT: Transcatheter aortic valve implantation using conventional delivery system.


Subject(s)
Aorta, Thoracic/abnormalities , Aortic Valve Stenosis/surgery , Heart Defects, Congenital/complications , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Angiography , Aortic Valve Stenosis/complications , Humans , Male , Tomography, X-Ray Computed
2.
Heart ; 99(1): 41-7, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22895641

ABSTRACT

BACKGROUND: In patients being considered for aortic valve replacement, there remains controversy over which design or tissue offers the best performance. We aimed to evaluate in a single study the haemodynamic performances of five different widely used aortic valve prostheses: stentless porcine xenograft (Elan), stentless bovine pericardium (Pericarbon Freedom), stented porcine xenograft (Aspire), stented bovine pericardium (More) and mechanical (Ultracor). We also compared them with normal aortic valves and stenosed valves of variable severity. METHODS AND RESULTS: Preoperative echocardiography and dobutamine stress echocardiography at 1 year postoperatively were undertaken in 106 patients (n=18-24 from each group). Stentless bioprostheses, whether porcine or bovine, displayed superior haemodynamics across nearly all echocardiographic parameters: lower gradients, larger effective orifice area, higher dimensionless severity index (DSI) and lower resistance, when compared with stented or mechanical prostheses. Comparing both stented designs, bovine tissue performed the worst at rest, but with stress, there was no difference. The stress performances of the stentless bioprostheses were similar to the mildly stenosed native aortic valve, whereas the performances of the stented and mechanical prostheses resembled that of native valves with mild-to-moderate stenoses. Haemodynamic differences, however, did not translate into differences in left ventricular mass reduction at 1 year. CONCLUSIONS: Stentless bioprostheses displayed haemodynamics superior to stented or mechanical prostheses and had the closest performance to a normal, native aortic valve. Stress DSI data, least reliant on variable annulus/valve sizes and flow rates, provided the best haemodynamic discrimination.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve/surgery , Bioprosthesis , Echocardiography, Stress/methods , Heart Valve Prosthesis , Hemodynamics/physiology , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Middle Aged , Prosthesis Design , Stents , Treatment Outcome
4.
JAMA ; 294(18): 2323-9, 2005 Nov 09.
Article in English | MEDLINE | ID: mdl-16278360

ABSTRACT

CONTEXT: Although left atrial radiofrequency ablation (RFA) is increasingly used for the treatment of chronic atrial fibrillation during mitral valve surgery, its efficacy to restore sinus rhythm and any resulting benefits have not been examined in the context of an adequately powered randomized trial. OBJECTIVE: To determine whether intraoperative RFA of the left atrium increases the long-term restoration of sinus rhythm and improves exercise capacity. DESIGN, SETTING, AND PATIENTS: Randomized, double-blind trial performed in a single UK tertiary referral center with enrollment between December 2001 and November 2003. A total of 101 patients referred for mitral valve surgery with at least 6 months' history of uninterrupted atrial fibrillation were assessed for eligibility; 97 were enrolled. Patients were followed up for 12 months. INTERVENTION: Patients were randomly assigned to undergo mitral valve surgery and RFA of the left atrium (n = 49) or mitral valve surgery alone (controls; n = 48). MAIN OUTCOME MEASURES: The primary outcome measure was presence of sinus rhythm at 12 months; secondary measures were patient functional status and exercise capacity (assessed by shuttle-walk test), left atrial contractility, and left atrial and left ventricular dimension and function and plasma levels of B-type natriuretic peptide. RESULTS: At 12 months, sinus rhythm was present in 20 (44.4%) of 45 RFA patients and in 2 (4.5%) of 44 controls (rate ratio, 9.8; 95% CI, 2.4-86.3; P<.001). Restoration of sinus rhythm in the RFA group was accompanied by a greater improvement in mean (SD) shuttle-walk distance compared with controls (+94 [102] m vs +48 [82] m; P = .003) and a greater reduction in the plasma level of B-type natriuretic peptide (-104 [87] fmol/mL vs -51 [82] fmol/mL; P = .03). Patients randomized to receive RFA had similar rates of postoperative complications and deaths as control patients. CONCLUSIONS: Radiofrequency ablation of the left atrium during mitral valve surgery for continuous atrial fibrillation significantly increases the rate of sinus rhythm restoration 1 year postoperatively, improving patient exercise capacity. On the basis of its efficacy and safety, routine use of RFA of the left atrium during mitral valve surgery may be justified. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00238706.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Mitral Valve/surgery , Aged , Atrial Fibrillation/blood , Atrial Fibrillation/physiopathology , Cardiac Surgical Procedures , Double-Blind Method , Female , Heart Atria , Heart Function Tests , Heart Rate , Humans , Intraoperative Period , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Treatment Outcome
5.
J Am Coll Cardiol ; 45(7): 1043-50, 2005 Apr 05.
Article in English | MEDLINE | ID: mdl-15808762

ABSTRACT

OBJECTIVES: We sought to compare urinary and plasma N-terminal pro-brain natriuretic peptide (N-BNP) in left ventricular systolic dysfunction (LVSD) diagnosis. BACKGROUND: Plasma N-BNP is elevated in LVSD. Renal tubule cells produce BNP. We tested the incremental value of urinary N-BNP in LVSD diagnosis. METHODS: In this prospective, community-screening study of undiagnosed LVSD, 1,360 subjects (45 to 80 years of age) were invited, and 1,308 had analyzable echocardiographic scans and urine and plasma specimens. The criterion standard for LVSD was defined as a wall motion score over 1.8 (ejection fraction < or =40%). RESULTS: Twenty-eight patients with LVSD had elevated urinary and plasma N-BNP levels compared with normal subjects (p < 0.0005). Receiver-operating characteristic (ROC) areas under the curve (AUCs) for urinary and plasma N-BNP were 0.831 and 0.840, respectively. Both tests had high negative predictive values (>99%) for excluding LVSD. Urinary N-BNP was more specific (67.2%) than plasma N-BNP (41%). The plasma/urinary N-BNP product yielded a higher ROC-AUC (0.923) and specificity (78%), reducing the number of cases to scan to detect one case of LVSD to 11.4 (compared with 16.6 [urinary N-BNP] and 29.0 [plasma N-BNP]). Sequential application of tests (urinary N-BNP, then plasma N-BNP in the urine-"positive" cases) achieved similar reductions in the number of cases to scan (10.8), while limiting the number of N-BNP tests to be performed. Urinary N-BNP performed poorly in detection of other cardiac abnormalities with preserved systolic function. It was less costly to test urinary N-BNP in the whole population as compared with other strategies, including scanning high-risk cases with N-BNP testing in the remainder. CONCLUSIONS: Urinary N-BNP used together with plasma N-BNP could reduce the echocardiographic burden in screening programs.


Subject(s)
Mass Screening/methods , Natriuretic Peptide, Brain/blood , Natriuretic Peptide, Brain/urine , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/epidemiology , Aged , Aged, 80 and over , Area Under Curve , Blood Chemical Analysis/standards , Blood Chemical Analysis/statistics & numerical data , Cohort Studies , Community Health Services , Echocardiography/statistics & numerical data , England/epidemiology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , ROC Curve , Sensitivity and Specificity , Systole , Urinalysis/standards , Urinalysis/statistics & numerical data , Ventricular Dysfunction, Left/blood , Ventricular Dysfunction, Left/etiology
6.
Eur J Heart Fail ; 5(6): 775-82, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14675856

ABSTRACT

AIMS: We examined strategies to improve the positive predictive value of natriuretic peptides in screening for undiagnosed left ventricular systolic dysfunction (LVSD) in the community. METHODS AND RESULTS: The value of B-type(BNP), N-terminal proB-type (N-BNP) and N-terminal proAtrial(N-ANP) natriuretic peptides was prospectively assessed in 1360 subjects (45-80 years) together with echocardiography and electrocardiography. Seventeen individuals had definite and 13 had borderline, LVSD. Receiver-operating-characteristic (ROC) curve analysis showed the superiority of BNP (ROC areas 0.942 for definite LVSD, P<0.03; 0.934 for borderline LVSD, P<0.003) compared to N-BNP or N-ANP. Peptide levels, major ECG abnormality and ischaemic heart disease (IHD) history were independent predictors of LVSD. Logistic regression modelling incorporating these factors improved ROC areas for all natriuretic peptides. The specificity of all natriuretic peptides is enhanced by consideration of these factors. CONCLUSIONS: In population screening for definite LVSD, consideration of plasma natriuretic peptide levels together with the presence of major ECG abnormalities and IHD history reduces by a factor of six (in comparison to consideration of plasma natriuretic peptide levels in isolation) the number of subjects requiring echocardiography to detect one case of LVSD (for BNP, 44 falling to seven). Similar improvements were evident for N-ANP and N-BNP. Inclusion of major ECG abnormalities and IHD history improves the performance of any natriuretic peptide used in screening programmes for ruling in undiagnosed LVSD.


Subject(s)
Atrial Natriuretic Factor/blood , Electrocardiography , Mass Screening/methods , Ventricular Dysfunction, Left/diagnosis , Aged , Aged, 80 and over , Biomarkers/blood , Echocardiography , Electrocardiography/methods , Female , Humans , Logistic Models , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Prospective Studies , Protein Precursors/blood , ROC Curve , Stroke Volume , Ventricular Dysfunction, Left/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...