1.
Micromachines (Basel) ; 9(2)2018 Jan 31.
Article in English | MEDLINE | ID: mdl-30393333

ABSTRACT

Breakup of droplets at bi-layer bifurcating junction in polydimethylsiloxane (PDMS) microchannel has been investigated by experiments and numerical simulation. The pressure drop in bi-layer bifurcating channel was investigated and compared with single-layer bifurcating channel. Daughter droplet size variation generated in bi-layer bifurcating microchannel was analyzed. The correlation was proposed to predict the transition between breakup and non-breakup conditions of droplets in bi-layer bifurcating channel using a phase diagram. In the non-breakup regime, droplets exiting port can be switched via tuning flow resistance by controlling radius of curvature, and or channel height ratio. Compared with single-layer bifurcating junction, 3-D cutting in diagonal direction from bi-layer bifurcating junction induces asymmetric fission to form daughter droplets with distinct sizes while each size has good monodispersity. Lower pressure drop is required in the new microsystem. The understanding of the droplet fission in the novel microstructure will enable more versatile control over the emulsion formation, fission and sorting. The model system can be developed to investigate the encapsulation and release kinetics of emulsion templated particles such as drug encapsulated microcapsules as they flow through complex porous media structures, such as blood capillaries or the porous tissue structures, which feature with bifurcating junctions.

2.
Ultrason Sonochem ; 27: 165-170, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26186833

ABSTRACT

Ultrasonic VialTweeter is used for the sonication of small volume samples. It contains a titanium block with 8 holes for vial insertion, to be used simultaneously for batch operation. In this investigation, the ultrasonic and sonochemical performance of ultrasonic VialTweeter has been evaluated at its different positions. Experimental results using calorimetry, ultrasonic capillary effect, sonochemiluminescence and degradation of Rhodamine B showed that the sonochemical activity differs greatly at different positions along the VialTweeter, with positions 3 and 4 showing the maximum efficiency whereas the positions 1 and 2 being the least effective positions. These results were further verified by acoustic pressure simulation, confirming that certain locations in the VialTweeter may not perform in the same way as others due to the variation in acoustic pressure at different locations.

SELECTION OF CITATIONS
SEARCH DETAIL