Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37862532

ABSTRACT

A half-wave plate (HWP) is often used as a modulator to suppress systematic error in the measurements of cosmic microwave background (CMB) polarization. A HWP can also be used to measure circular polarization (CP) through its optical leakage from CP to linear polarization. The CP of the CMB is predicted from various sources, such as interactions in the Universe and extension of the standard model. Interaction with supernova remnants of population III stars is one of the brightest CP sources. Thus, the observation of the CP of CMB is a new tool for searching for population III stars. In this paper, we demonstrate the improved measurement of the leakage coefficient using the transmission measurement of an actual HWP in the laboratory. We measured the transmittance of linearly polarized light through the HWP used in Polarbear in the frequency range of 120-160 GHz. We evaluate the properties of the HWP by fitting the data with a physical model using the Markov Chain Monte Carlo method. We then estimate the band-averaged CP leakage coefficient using the physical model. We find that the leakage coefficient strongly depends on the spectra of CP sources. We thus calculate the maximum fractional leakage coefficient from CP to linear polarization as 0.133 ± 0.009 in the Rayleigh-Jeans spectrum. The nonzero value shows that Polarbear has a sensitivity to CP. Additionally, because we use the bandpass of detectors installed in the telescope to calculate the band-averaged values, we also consider systematic effects in the experiment.

2.
Phys Rev Lett ; 124(13): 131301, 2020 Apr 03.
Article in English | MEDLINE | ID: mdl-32302154

ABSTRACT

Using only cosmic microwave background polarization data from the polarbear experiment, we measure B-mode polarization delensing on subdegree scales at more than 5σ significance. We achieve a 14% B-mode power variance reduction, the highest to date for internal delensing, and improve this result to 22% by applying for the first time an iterative maximum a posteriori delensing method. Our analysis demonstrates the capability of internal delensing as a means of improving constraints on inflationary models, paving the way for the optimal analysis of next-generation primordial B-mode experiments.

3.
Rev Sci Instrum ; 90(11): 115115, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31779409

ABSTRACT

We describe the Fourier Transform Spectrometer (FTS) used for in-field testing of the POLARBEAR receiver, an experiment located in the Atacama Desert of Chile which measures the cosmic microwave background (CMB) polarization. The POLARBEAR-FTS (PB-FTS) is a Martin-Puplett interferometer designed to couple to the Huan Tran Telescope (HTT) on which the POLARBEAR receiver is installed. The PB-FTS measured the spectral response of the POLARBEAR receiver with signal-to-noise ratio >20 for ∼69% of the focal plane detectors due to three features: a high throughput of 15.1 sr cm2, optimized optical coupling to the POLARBEAR optics using a custom designed output parabolic mirror, and a continuously modulated output polarizer. The PB-FTS parabolic mirror is designed to mimic the shape of the 2.5 m-diameter HTT primary reflector, which allows for optimum optical coupling to the POLARBEAR receiver, reducing aberrations and systematics. One polarizing grid is placed at the output of the PB-FTS and modulated via continuous rotation. This modulation allows for decomposition of the signal into different harmonics that can be used to probe potentially pernicious sources of systematic error in a polarization-sensitive instrument. The high throughput and continuous output polarizer modulation features are unique compared to other FTS calibrators used in the CMB field. In-field characterization of the POLARBEAR receiver was accomplished using the PB-FTS in April 2014. We discuss the design, construction, and operation of the PB-FTS and present the spectral characterization of the POLARBEAR receiver. We introduce future applications for the PB-FTS in the next-generation CMB experiment, the Simons Array.

4.
Phys Rev Lett ; 113(2): 021301, 2014 Jul 11.
Article in English | MEDLINE | ID: mdl-25062161

ABSTRACT

Gravitational lensing due to the large-scale distribution of matter in the cosmos distorts the primordial cosmic microwave background (CMB) and thereby induces new, small-scale B-mode polarization. This signal carries detailed information about the distribution of all the gravitating matter between the observer and CMB last scattering surface. We report the first direct evidence for polarization lensing based on purely CMB information, from using the four-point correlations of even- and odd-parity E- and B-mode polarization mapped over ∼30 square degrees of the sky measured by the POLARBEAR experiment. These data were analyzed using a blind analysis framework and checked for spurious systematic contamination using null tests and simulations. Evidence for the signal of polarization lensing and lensing B modes is found at 4.2σ (stat+sys) significance. The amplitude of matter fluctuations is measured with a precision of 27%, and is found to be consistent with the Lambda cold dark matter cosmological model. This measurement demonstrates a new technique, capable of mapping all gravitating matter in the Universe, sensitive to the sum of neutrino masses, and essential for cleaning the lensing B-mode signal in searches for primordial gravitational waves.

5.
Phys Rev Lett ; 112(13): 131302, 2014 Apr 04.
Article in English | MEDLINE | ID: mdl-24745402

ABSTRACT

We reconstruct the gravitational lensing convergence signal from cosmic microwave background (CMB) polarization data taken by the Polarbear experiment and cross-correlate it with cosmic infrared background maps from the Herschel satellite. From the cross spectra, we obtain evidence for gravitational lensing of the CMB polarization at a statistical significance of 4.0σ and indication of the presence of a lensing B-mode signal at a significance of 2.3σ. We demonstrate that our results are not biased by instrumental and astrophysical systematic errors by performing null tests, checks with simulated and real data, and analytical calculations. This measurement of polarization lensing, made via the robust cross-correlation channel, not only reinforces POLARBEAR auto-correlation measurements, but also represents one of the early steps towards establishing CMB polarization lensing as a powerful new probe of cosmology and astrophysics.

6.
Rev Sci Instrum ; 83(5): 056104, 2012 May.
Article in English | MEDLINE | ID: mdl-22667668

ABSTRACT

We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two-point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.

7.
Rev Sci Instrum ; 82(5): 054501, 2011 May.
Article in English | MEDLINE | ID: mdl-21639525

ABSTRACT

We present a novel system to calibrate millimeter-wave polarimeters for cosmic microwave background (CMB) polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however, it employs cryogenically-cooled blackbody absorbers. The primary advantage of this system is that it can generate a slightly polarized signal (∼100 mK) in the laboratory; this is at a similar level to that measured by ground-based CMB polarization experiments observing a ∼10 K sky. It is important to reproduce the observing condition in the laboratory for reliable characterization of polarimeters before deployment. In this paper, we present the design and principle of the system and demonstrate its use with a coherent-type polarimeter used for an actual CMB polarization experiment. This technique can also be applied to incoherent-type polarimeters and it is very promising for the next-generation CMB polarization experiments.

SELECTION OF CITATIONS
SEARCH DETAIL
...