1.
Indian J Anaesth ; 63(10): 814-819, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31649393

ABSTRACT

BACKGROUND AND AIMS: Safety and economy are the main concerns while using low- flow anaesthesia with newer inhalational agents. The main objective of this study was to use and compare 'equilibration time' of sevoflurane and desflurane after change-over from high-to-low flow anaesthesia. METHODS: This prospective study included consenting adult patients between 18-70 years undergoing elective surgery under general anaesthesia. Patients were randomised initially to receive high-flow anaesthesia with 1.3 MAC of either desflurane or sevoflurane with nitrous oxide. After equilibration point, low-flow anaesthesia was initiated. Heart rate, non-invasive blood pressure, pulse oximeter, 5 electrode ECG and gas monitoring was done. Statistical analysis was done with the help of Med CalC version 12.5.0.0 (student version) and IBM SPSS Version 20.0. RESULTS: Mean equilibration time in sevoflurane group was higher (4.59 ± 0.77 minutes) than desflurane group (3.78 ± 0.56 minutes, P < 0.001). Inspired concentrations of both inhalational agents varied from their vaporiser settings over 2 hours, more so with sevoflurane than desflurane. Inspired oxygen concentration (FiO2) remained above 30% during anaesthesia in both groups with stable haemodynamics. CONCLUSION: Change-over from high-to-low flow anaesthesia is faster in desflurane. With fresh gas flow (FGF) of 1 L with 50% oxygen and dial concentration of 1-1.5% of sevoflurane and 3.8-4.4% of desflurane, the risk of hypoxia is minimal. The disparity between the set and delivered concentrations is more (20%) in sevoflurane than desflurane (12%).

2.
Indian J Anaesth ; 61(3): 272-273, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28405046
4.
Indian J Anaesth ; 59(6): 365-8, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26195833

ABSTRACT

BACKGROUND AND AIMS: Shoulder arthroscopy requires fluid irrigation, which causes soft-tissue oedema around chest, neck, and arm intraoperatively, leading to postoperative airway complications. We decided to study the incidence of increase in the neck circumference in shoulder arthroscopy and its effects on the airway. METHODS: We studied 32 cases of shoulder arthroscopies over a period of 1-year, performed under general anaesthesia with interscalene block. The neck circumference of patients before and after the procedure was measured along with other parameters. The endotracheal tube cuff was deflated at the end of surgery to determine air leak around the tube. The negative leak test suggested airway oedema. RESULTS: Thirty out of 32 patients showed positive air leak test. The average change in neck circumference was 1.17 ± 1.16 cm and all could be extubated uneventfully. Two showed negative leak test with an increase in neck circumference by 4.5 and 6.4 cm and were not extubated. Multiple regression analysis for risk factors showed intraoperative hypertension as a single predictor for an increase in neck circumference. CONCLUSION: Change in the neck circumference beyond 4 cm may suggest airway compromise and below 4 cm, airway compromise is unlikely even in the presence of extensive soft-tissue oedema around the shoulder, upper arm and chest.

6.
J Anaesthesiol Clin Pharmacol ; 28(3): 330-3, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22869939

ABSTRACT

BACKGROUND: It is well documented that pressure-controlled ventilation (PCV) improves oxygenation and ventilation compared to volume-controlled ventilation and reduces peak airway pressure in gynecological laparoscopy. PCV with moderately inversed inspiratory-expiratory (I: E) ratio can successfully recruit collapsed alveoli and has been proved to be beneficial in intensive care. We tested the hypothesis that altering the I: E ratio to 1.5:1 in PCV improves ventilation during gynecological laparoscopy using laryngeal mask airway (LMA). OBJECTIVE: To study pressure-controlled inverse ratio ventilation (PCIRV) with I: E ratio 1.5:1 as against PCV with I: E ratio 1:2 in gynecological laparoscopy with LMA using noninvasive parameters. MATERIALS AND METHODS: Intraoperative hemodynamics and side-stream spirometry recordings were noted in 20 consecutive patients undergoing major gynecological laparoscopy with LMA. Flexible LMA or LMA supreme were used depending on normal body mass index (BMI) or high BMI, respectively. RESULTS: REVERSING THE I: E ratio to 1.5:1 increased the tidal volume, mean airway pressures, and dynamic lung compliance significantly, all indicating better oxygenation at comparable peak airway pressures as against PCV with I: E ratio 1:2. There was no change in the end-tidal carbon dioxide. There was no auto-positive end expiratory pressure (PEEP) or change in the hemodynamics. CONCLUSION: REVERSAL OF I: E ratio with PCV can be beneficially used with LMA in laparoscopy.

7.
9.
J Gynecol Endosc Surg ; 2(1): 18-20, 2011 Jan.
Article in English | MEDLINE | ID: mdl-22442529

ABSTRACT

Recent advances in the practice of anesthsiology ensure that we move closer to our goal of zero morbidity. It is of critical importance that we couple our clinical expertise with the sophisticated monitoring equipment and get the best out of them.