Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38552177

ABSTRACT

AIMS: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve outcomes in patients with symptomatic, refractory atrial fibrillation (AF). Superior approach (SA) from the pocket, via axillary or subclavian vein, has been recently proposed as an alternative to the conventional femoral venous approach (FA) to perform AVJA. In this study we compared the impact of these alternative approaches on the nurse workload (NWL) and on patient satisfaction. METHODS AND RESULTS: Prospective, observational study, enrolling consecutive patients undergoing simultaneous CSP and AVJA. ElectrophysiologyLaboratory (EP Lab) NWL was calculated with a self-developed model. Ward NWL was calculated using the MIDENF® validated scale. Patient satisfaction was collected using the Hospital Consumer Assessment of Healthcare Provider Systems (HCAHPS) questionnaire. A total of 119 patients were enrolled: in 50, AVJA was primarily attempted with SA, in 69 from FA. Compared to FA, SA was associated with a lower EP Lab NWL (169.8±26.7 vs. 202.7±38.9 minutes; p<0.001), and a lower Ward NWL (474.5±184.8 vs. 808.6±289.9 minutes; p<0.001). Multivariate analysis identified SA as an independent predictor of lower EP Lab NWL (hazard ratio 4.60; p=0.001), and of lower Ward NWL (hazard ratio 45.13; p<0.001). Compared to FA, SA was associated with a higher patient-reported rating regarding the experience during hospital stay (p=0.035), and the overall hospital evaluation (p=0.026). CONCLUSIONS: In patients undergoing simultaneous CSP and AVJA, the use of a SA for ablation is a valid alternative to conventional FA. Compared to FA, this approach significantly reduces NWL, and is associated with greater patient satisfaction.

3.
Expert Rev Med Devices ; 18(5): 483-491, 2021 May.
Article in English | MEDLINE | ID: mdl-33888044

ABSTRACT

BACKGROUND: Leadless pacemaker (L-PM) have been developed in order to overcome the lead- and pocket-related complications associated with transvenous pacemaker (T-PM). The impact of L-PM implantation on the utilization of medical resources, patient comfort and therapy acceptance could differ from that of T-PM. RESEARCH DESIGN AND METHODS: Prospective, single-center study enrolling 243 consecutive patients undergoing PM implantation. Propensity matching for baseline characteristics yielded 77 matched pairs. Procedural data, patient acceptance (assessed by Florida Patient Acceptance Survey, FPAS) and quality of life (QoL) (assessed at the baseline, 1 week, 3 and 6 months) were compared between the two groups (L-PM and T-PM). RESULTS: The implantation procedure was longer in L-PM than T-PM patients (42.2±16.3 vs. 28.9±11.9 minutes; p<0.001). L-PM was associated with lower intra- and post-operative pain intensity (all p<0.05), shorter hospitalization (3.2±0.5 vs. 3.5±1.1 days; p=0.034), greater patient acceptance (FPAS score: 58.7±7.1 vs. 40.5±4.1; p<0.001), and better QoL on both physical and mental health scales (all p<0.05). CONCLUSIONS: Although L-PM implantation takes longer than T-PM, it is better tolerated and accepted by patients and is associated with a better QoL.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Patient Acceptance of Health Care , Aged , Aged, 80 and over , Electrodes , Female , Follow-Up Studies , Health Resources , Humans , Male , Postoperative Complications/etiology , Propensity Score , Prospective Studies , Quality of Life , Surveys and Questionnaires , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL