Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Oral Implantol ; 49(6): 616-628, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38258587

ABSTRACT

Peri-implant diseases have become one of the notable biological complications of postrehabilitation with implant-supported restorations. Effective modalities for decontamination of biofilm deposits around implant surfaces are critical for resolution of the inflammation. Air polishing is one of the recommended clinical methods for treating peri-implant diseases. This systematic review assessed clinical evidence on efficacy of using air polishing technology for the management of peri-implant diseases, including peri-implant mucositis and peri-implantitis. Four electronic databases from January 1990 to December 2022 were searched to identify the relative human randomized clinical trials that applied air polishing for nonsurgical and surgical treatment of peri-implant mucositis and peri-implantitis. Twelve articles were selected. For treating peri-implant mucositis, air polishing showed a comparable effect to ultrasonic scaling in the reduction of bleeding on probing (BOP) and probing pocket depth (PPD). The nonsurgical approach of air polishing in treating peri-implantitis varied in the reduction of BOP, PPD, and clinical attachment level (CAL) in evaluated studies. Air polishing in the surgical treatment of peri-implantitis was comparable to mechanical cleaning, implantoplasty, and the use of Ti-brush, in regards to the significant reduction of BOP, PPD, and CAL, as well as the improvement of the bone level between baseline and follow-ups. The standardized mean difference with a 95% confidence interval of the studied parameters was estimated using the random effect model; however, statistical differences were not detected between air polishing and comparative modalities in the treatment of peri-implantitis. Within the limitations of this review, the application of air polishing did not result in more favorable outcomes in the treatment of peri-implant diseases compared to other modalities.


Subject(s)
Dental Implants , Mucositis , Peri-Implantitis , Humans , Peri-Implantitis/surgery , Dental Implants/adverse effects , Dental Polishing/methods , Biofilms
2.
Neurocrit Care ; 36(2): 350-356, 2022 04.
Article in English | MEDLINE | ID: mdl-34845596

ABSTRACT

BACKGROUND: The aim of this study was to describe the utilization patterns of brain tissue oxygen (PbtO2) monitoring following severe traumatic brain injury (TBI) and determine associations with mortality, health care use, and pulmonary toxicity. METHODS: We conducted a retrospective cohort study of patients from United States trauma centers participating in the American College of Surgeons National Trauma Databank between 2008 and 2016. We examined patients with severe TBI (defined by admission Glasgow Coma Scale score ≤ 8) over the age of 18 years who survived more than 24 h from admission and required intracranial pressure (ICP) monitoring. The primary exposure was PbtO2 monitor placement. The primary outcome was hospital mortality, defined as death during the hospitalization or discharge to hospice. Secondary outcomes were examined to determine the association of PbtO2 monitoring with health care use and pulmonary toxicity and included the following: (1) intensive care unit length of stay, (2) hospital length of stay, and (3) development of acute respiratory distress syndrome (ARDS). Regression analysis was used to assess differences in outcomes between patients exposed to PbtO2 monitor placement and those without exposure by using propensity weighting to address selection bias due to the nonrandom allocation of treatment groups and patient dropout. RESULTS: A total of 35,501 patients underwent placement of an ICP monitor. There were 1,346 (3.8%) patients who also underwent PbtO2 monitor placement, with significant variation regarding calendar year and hospital. Patients who underwent placement of a PbtO2 monitor had a crude in-hospital mortality of 31.1%, compared with 33.5% in patients who only underwent placement of an ICP monitor (adjusted risk ratio 0.84, 95% confidence interval 0.76-0.93). The development of the ARDS was comparable between patients who underwent placement of a PbtO2 monitor and patients who only underwent placement of an ICP monitor (9.2% vs. 9.8%, adjusted risk ratio 0.89, 95% confidence interval 0.73-1.09). CONCLUSIONS: PbtO2 monitor utilization varied widely throughout the study period by calendar year and hospital. PbtO2 monitoring in addition to ICP monitoring, compared with ICP monitoring alone, was associated with a decreased in-hospital mortality, a longer length of stay, and a similar risk of ARDS. These findings provide further guidance for clinicians caring for patients with severe TBI while awaiting completion of further randomized controlled trials.


Subject(s)
Brain Injuries, Traumatic , Respiratory Distress Syndrome , Adult , Brain , Brain Injuries, Traumatic/therapy , Humans , Intracranial Pressure , Middle Aged , Monitoring, Physiologic , Respiratory Distress Syndrome/therapy , Retrospective Studies
3.
J Orthop Translat ; 22: 43-49, 2020 May.
Article in English | MEDLINE | ID: mdl-32440498

ABSTRACT

INTRODUCTION: Long-term study evidence about the BioBall® adapter system is limited, especially in highly morbid elderly patients. Thus, we analysed the long-term outcome of revision hip arthroplasty using this system in highly morbid elderly patients. MATERIALS AND METHODS: We included 19 patients undergoing revision hip arthroplasty after primary or secondary total hip arthroplasty dislocations between July 2002 and August 2004 and followed up their long-term outcome until 2015. RESULTS: The patients achieved a median of 17 points in the Merle d'Aubigné hip score in 2004 and a median of 18 points in 2011, and the 4 surviving patients in 2015 achieved 18 points. For the four 12-year survivors, the Merle d'Aubigné score was virtually stable over the complete observation period. The Harris Hip Score showed comparable results. The patients had a median Barthel index of 90 in 2004 and 100 in 2011, and the 4 survivors in 2015 had Barthel indices of 65, 95, 100, and 100, respectively, in 2015. CONCLUSIONS: In multimorbid patients, using the BioBall® adapter system for total hip arthroplasty, revision due to dislocation results in good long-term outcome without impairment of quality of life. TRANSLATIONAL POTENTIAL: Our study provides long-term evidence in a vulnerable patient population. It shows how the therapeutic concept of revision hip replacement with an adapter device translates into long-term outcome and quality of life in these patients. Thus, it adds important information for evaluation of therapeutic options in this field.

SELECTION OF CITATIONS
SEARCH DETAIL
...