Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pediatr Cardiol ; 40(6): 1217-1223, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31218374

ABSTRACT

We designed the newly developed flexed two-finger chest compression technique for cardiopulmonary resuscitation (CPR) in infants to increase the quality of chest compression by considering the advantages and disadvantages of the two-thumb encircling hand technique and conventional two-finger technique. The aim of the study is to compare the performance of the flexed two-finger technique and the currently used two-thumb technique or two-finger technique for infant CPR. A total of 42 doctors conducted 2-min single-rescuer CPR on a cardiac arrest infant model using the two-thumb technique followed, in a random order, by the two-finger technique and the flexed two-finger technique. Although the ratio of the adequate compression depth was highest in the two-thumb technique, followed by the flexed two-finger technique and two-finger technique (100% [98-100] vs. 99% [80-100] vs. 76% [42-95], respectively, P < 0.001), the hand-off time of the two-thumb technique was significantly longer than in the two-finger technique and flexed two-finger technique (31 s [28-35] vs. 29 s [27-32] vs. 29 s [26-32], respectively, P < 0.001). The number of total chest compressions of the two-thumb technique was significantly lower than in the two-finger technique and flexed two-finger technique (150 [148-159] vs. 159 [149-173] vs. 162 [150-172], respectively, P < 0.001). The newly developed chest compression technique could provide adequate compression depth without increasing the hand-off time during single-rescuer infant CPR.Trial registration: Clinical Research Information Service, KCT0002730.


Subject(s)
Cardiopulmonary Resuscitation/methods , Heart Massage/methods , Adult , Cross-Over Studies , Female , Fingers , Heart Arrest/therapy , Humans , Infant , Male , Manikins
2.
Ann Rehabil Med ; 43(6): 642-649, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31918527

ABSTRACT

OBJECTIVE: To investigate the correlation between mechanography and clinical parameters in older people at 3 and 6 months after hip fracture surgery. METHODS: A longitudinal follow-up study was conducted in university hospitals with 38 patients at 3 months and 29 patients at 6 months after hip fracture surgery. Subjects 65 years and older completed measurements on the Berg Balance Scale (BBS), Functional Ambulation Category (FAC), walking ability by Koval, Korean version of the fatigue, resistance, ambulation, illnesses, and loss of weight (K-FRAIL) scale, and hand grip strength. The Romberg test with center of foot pressure (COP), chair rise test (CRT), and maximal power (W/kg) were conducted using the Leonardo Mechanograph. RESULTS: COP area and pathway length were correlated with BBS at 3 and 6 months. Change in BBS was correlated with change in COP area, but not with change in COP length. COP area and pathway length were correlated with K-FRAIL at 3 months after hip fracture surgery. The same COP variables showed correlations with FAC and walking ability by Koval at 6 months after surgery. Maximal power during CRT had correlation with chair rise time but not with other clinical parameters. CONCLUSION: The study revealed correlations between mechanography and clinical parameters in older people at 3 and 6 months after hip fracture surgery. Both the clinical assessment and objective test with mechanography may be required for the quantitative and sensitive measurement of postural balance and lower limb muscle power.

SELECTION OF CITATIONS
SEARCH DETAIL
...