Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Omega ; 5(37): 23983-23988, 2020 Sep 22.
Article in English | MEDLINE | ID: mdl-32984719

ABSTRACT

CdS has been known to be one of the best junction partners for Cu(In,Ga)Se2 (CIGS) in CIGS solar cells. However, the use of thick CdS buffer decreases the short-circuit current density of CIGS solar cells. There are two obstacles that limit the use of ultrathin CdS. The first is plasma damage to CIGS during the preparation of transparent conducting windows and the second is a low shunt resistance due to the direct contact between the window and CIGS via pinholes in the thin CdS buffer. In other words, to avoid plasma damage and shunt paths, we may have to use a CdS buffer that is thicker than necessary to form a high-quality CdS/CIGS junction. This work aims to determine how thin the CdS buffer can be employed without sacrificing device performance while also eliminating the above two obstacles. We investigate the effect of CdS thickness on the performance of CIGS solar cells with silver nanowire-based window layers, which can eliminate both obstacles. An approximately 13 nm thick CdS buffer allows us to achieve high short-circuit current density and fill factor values. To attain an even high open-circuit voltage, an additional CdS buffer with a thickness of 13 nm is needed. The data from this study imply that an approximately 26 nm thick CdS buffer is sufficient to form a high-quality CdS/CIGS junction.

2.
Data Brief ; 25: 104407, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31516932

ABSTRACT

The authors have recently reported silver nanowire based Cu(In,Ga)Se2 solar cells [1,2]. Metal mesh based transparent electrodes other than the silver nanowire can be also employed or have a potential to provide a better performance for the solar cells. To select a suitable electrode for a solar cell among metal meshes, it is required to have data on the lateral collection length of charge carriers in the targeted cell. The method to determine the lateral collection has been reported in our previous publication [3]. Here, we report data on the effect of the light intensity during pre-white-light soaking on the lateral charge collection length for metal mesh transparent electrode based Cu(In,Ga)Se2 solar cells.

3.
J Vis Exp ; (149)2019 07 19.
Article in English | MEDLINE | ID: mdl-31380832

ABSTRACT

Silver nanowire transparent electrodes have been employed as window layers for Cu(In,Ga)Se2 thin-film solar cells. Bare silver nanowire electrodes normally result in very poor cell performance. Embedding or sandwiching silver nanowires using moderately conductive transparent materials, such as indium tin oxide or zinc oxide, can improve cell performance. However, the solution-processed matrix layers can cause a significant number of interfacial defects between transparent electrodes and the CdS buffer, which can eventually result in low cell performance. This manuscript describes how to fabricate robust electrical contact between a silver nanowire electrode and the underlying CdS buffer layer in a Cu(In,Ga)Se2 solar cell, enabling high cell performance using matrix-free silver nanowire transparent electrodes. The matrix-free silver nanowire electrode fabricated by our method proves that the charge-carrier collection capability of silver nanowire electrode-based cells is as good as that of standard cells with sputtered ZnO:Al/i-ZnO as long as the silver nanowires and CdS have high-quality electrical contact. The high-quality electrical contact was achieved by depositing an additional CdS layer as thin as 10 nm onto the silver nanowire surface.


Subject(s)
Electric Conductivity , Nanowires , Silver , Cadmium Compounds/chemistry , Electrodes , Solar Energy , Sulfates/chemistry , Zinc Oxide
4.
Korean J Radiol ; 9(1): 10-8, 2008.
Article in English | MEDLINE | ID: mdl-18253071

ABSTRACT

OBJECTIVE: To correlate high resolution dynamic MR features with prognostic factors in breast cancer. MATERIALS AND METHODS: One hundred and ninety-four women with invasive ductal carcinomas underwent dynamic MR imaging using T1-weighted three-dimensional fast low-angle shot (3D-FLASH) sequence within two weeks prior to surgery. Morphological and kinetic MR features were determined based on the breast imaging and reporting data system (BI-RADS) MR imaging lexicon. Histological specimens were analyzed for tumor size, axillary lymph node status, histological grade, expression of estrogen receptor (ER), expression of progesterone receptor (PR), and expression of p53, c-erbB-2, and Ki-67. Correlations between the MR features and prognostic factors were determined using the Pearson chi(2) test, linear-by-linear association, and logistic regression analysis. RESULTS: By multivariate analysis, a spiculated margin was a significant, independent predictor of a lower histological grade (p < 0.001), and lower expression of Ki-67 (p = 0.007). Rim enhancement was significant, independent predictor of a higher histological grade (p < 0.001), negative expression of ER (p = 0.001), negative expression of PR (p < 0.001) and a larger tumor size (p = 0.006). A washout curve may predict a higher level of Ki-67 (p = 0.05). Most of the parameters of the initial enhancement phase cannot predict the status of the prognostic factors. Only the enhancement ratio may predict a larger tumor size (p = 0.05). CONCLUSION: Of the BI-RADS-MR features, a spiculated margin may predict favorable prognosis, whereas rim enhancement or washout may predict unfavorable prognosis of breast cancer.


Subject(s)
Breast Neoplasms/pathology , Carcinoma, Ductal/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Chi-Square Distribution , Contrast Media , Female , Gadolinium DTPA , Humans , Image Processing, Computer-Assisted , Logistic Models , Middle Aged , Neoplasm Invasiveness , Prognosis , Retrospective Studies
5.
Korean J Radiol ; 6(2): 102-9, 2005.
Article in English | MEDLINE | ID: mdl-15968149

ABSTRACT

OBJECTIVE: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. RESULTS: A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance (n = 5), and the imaging findings showing disease progression (n = 20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. CONCLUSION: The outcomes of the sonographically guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those outcomes of the biopsies performed with the 14-gauge automated gun in terms of underestimation, rebiopsy and the false negative rate, although these differences were not statistically significant.


Subject(s)
Biopsy/methods , Breast Neoplasms/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy/instrumentation , Breast Neoplasms/diagnostic imaging , Carcinoma in Situ/pathology , Carcinoma, Ductal/pathology , Disease Progression , False Negative Reactions , Female , Humans , Middle Aged , Retrospective Studies , Ultrasonography
6.
Korean J Radiol ; 6(1): 31-6, 2005.
Article in English | MEDLINE | ID: mdl-15782017

ABSTRACT

Ductography has become the gold standard for the evaluation of patients exhibiting pathologic nipple discharges. In nine patients (age range, 29-67 years; median age, 51 years) with invasive (n=5) or intraductal (n=4) cancer, ductographic findings were recorded, then correlated with mammographic and sonographic findings. Common ductographic findings included complete ductal obstruction, multiple irregular filling defects in the nondilated peripheral ducts, ductal wall irregularities, periductal contrast extravasation, and ductal displacement. Faint microcalcifications or ill-defined masses, which were not opacified by contrast material, were often discovered adjacent to ductal abnormalities. Mammographically and sonographically occult diffusely spreading intraductal cancers often manifested as pathologic nipple discharge. In such cases, meticulous ductographic examinations and interpretations were crucial in order not to miss breast cancers.


Subject(s)
Breast Neoplasms/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Nipples/diagnostic imaging , Adult , Aged , Female , Humans , Middle Aged , Radiography , Ultrasonography, Mammary
7.
J Clin Ultrasound ; 32(3): 115-22, 2004.
Article in English | MEDLINE | ID: mdl-14994251

ABSTRACT

PURPOSE: The aim of this study was to evaluate the role of preoperative sonography in predicting technical difficulties during laparoscopic cholecystectomy in patients with acute cholecystitis. METHODS: Sonographic assessment of 14 parameters was performed in 55 patients during a 9-month period: volume of gallbladder (GB), thickness of GB wall, pattern of GB wall thickening, size of largest gallstone, gallstone mobility, adhesion of GB to its bed, fat plane between GB and hepatoduodenal ligament, free fluid in GB fossa, common bile duct (CBD) dilatation, CBD stone(s), color and power Doppler signals in GB wall, and increased color and power Doppler signals in adjacent liver. Each of the 5 operative steps of laparoscopic cholecystectomy was scored as being difficult (1) or not (0). The scores for each step were added to obtain the overall difficulty score (0-5). We evaluated prospectively whether there were significant associations among the preoperative sonographic findings and the overall difficulty score, scores for each of the 5 operative steps, and operation time. RESULTS: The overall difficulty score was significantly associated with a GB volume of 50 cm(3) or more, GB wall thickness of 3 mm or more, and presence of color Doppler signals in the GB wall. Increased GB volume also made dissection of adhesions from the GB and dissection of Calot's triangle more difficult. Extraction of the GB from the abdomen was more difficult with a thickened GB wall or adhesion of the GB to its bed. The presence of a CBD stone, dilatation of the CBD (> or = 8 mm), color Doppler signals in the GB wall, and increased power Doppler signals in the adjacent liver were significantly associated with increased operation time. CONCLUSIONS: Based on our experience, preoperative determination of GB volume, GB wall thickness, and presence of color Doppler signals in the GB wall in patients with acute cholecystitis helps predict technical difficulties during laparoscopic cholecystectomy.


Subject(s)
Cholecystitis, Acute/diagnostic imaging , Preoperative Care , Ultrasonography, Doppler, Color , Adult , Aged , Cholecystectomy, Laparoscopic/methods , Cholecystitis, Acute/surgery , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis
SELECTION OF CITATIONS
SEARCH DETAIL
...