Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Nephrol ; 52(6): 479-486, 2021.
Article in English | MEDLINE | ID: mdl-34111865

ABSTRACT

INTRODUCTION: Successful cannulation of an arteriovenous fistula (AVF) is important in patients starting hemodialysis (HD). Metal needles have been used for decades, but the usefulness of plastic cannulae has recently been demonstrated as a new technique. METHODS: This was a prospective, randomized, open-label study of incident HD patients. Eligible patients were randomized into 2 groups in a 1:1 ratio (n = 45/group). Maturation of the AVF was confirmed using Doppler ultrasound prior to first needling, and 2 well-trained nurses implemented the AVF cannulation. The primary endpoint was the initial cannulation failure rate, defined as the failure of successful completion of 3 consecutive dialysis sessions. The secondary endpoints were time for hemostasis at the end of HD, degree of patients' pain, degree of cannulation difficulty felt by the nursing staffs, and achieving optimal HD adequacy. RESULTS: The mean elapsed time from AVF creation to the first cannulation was 48.1 ± 16.7 days. A total of 17 cases of cannulation failure occurred, and the failure risk tended to be higher in the metal needle group than the plastic cannula group (hazard ratio 2.6, 95% confidence interval 0.95-7.41) after adjusting for age, gender, comorbidities, and AVF location. The overall incidence of vessel injury was higher and time for hemostasis was significantly longer in the metal group than the plastic group. The use of plastic cannula was associated with a better HD adequacy compared to a metal needle. However, the patients' pain score (p = 0.004) and nursing staff's cannulation difficulty score (p = 0.084) were higher in the plastic group, emphasizing the great importance of practice using plastic cannulae. CONCLUSION: The vascular outcomes of plastic cannulae were much favorable compared to metal needles in incident HD patients. The use of plastic cannulae could be a new and innovative way to improve the quality of dialysis.


Subject(s)
Cannula , Catheterization, Peripheral/instrumentation , Needles , Renal Dialysis/instrumentation , Aged , Arteriovenous Shunt, Surgical , Blood Vessels/injuries , Cannula/adverse effects , Female , Hemostasis , Humans , Male , Metals , Middle Aged , Needles/adverse effects , Pain, Procedural/etiology , Plastics , Prospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...