Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Maxillofac Oral Surg ; 23(3): 462-474, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38911434

ABSTRACT

Fractures of the orbit are frequently noted in craniomaxillofacial trauma. The complexity of the anatomy and the proximity to various vital structures often complicates the surgical management of these fractures. The authors have thus attempted to review the literature on anatomy of the bony orbit and its soft tissue envelope in a simplified manner with due emphasis on surgical anatomy and exploration of the orbit with a surgical perspective. The contents of this narrative literature review may be useful for young maxillofacial surgeons and will aid in the process of management of orbital fractures.

2.
J Stomatol Oral Maxillofac Surg ; : 101927, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38830509

ABSTRACT

AIM: The purpose of this clinical study was to evaluate the efficacy of the preseptal transconjunctival approach with Y modification of the cutaneous extension for the management of zygomaticomaxillary complex (ZMC) fractures. METHODS: This prospective interventional study was conducted at our institute from 2012 to 2020. The study included patients aged 15-65 years with displaced ZMC fractures. Patients with uncontrolled systemic conditions, infected and/or comminuted fractures were excluded. The variables evaluated were age, gender, mechanism of injury, fracture side, clinical features, surgical exposure time, adequacy of exposure, complications, scar evaluation scores and cosmetic outcomes. The parameters for comparison were operated versus non operated side Eye Fissure Index (EFI) and surgical exposure time was compared with respect to the types of scars. RESULTS: A total of 49 patients were included in this study. The average exposure time was 18.87 ± 1.92 min. The exposure of fracture site was excellent in 73.5 % and satisfactory in 26.5 %. The mean EFI of operated side was 34.2 ± 5.04 mm while that of non-operated side was 34.22 ± 5 mm. On comparison of the same there was no significant difference. Invisible scars were noted in 71.4 % and barely visible scars in 22.4 %. The comparison of exposure time with type of scars showed a significant association (p = 0.02). The complications noted were chemosis, lower eyelid edema, conjunctival granuloma and entropion. Cosmetic outcomes were fairly satisfactory. CONCLUSION: The Y modification of the transconjunctival approach can provide excellent surgical exposure without the need for a second incision. Although this approach is technique sensitive and requires experience, the advantages outweigh the learning curve. Since this approach has been widely studied, a systematized review is recommended to further substantiate its reliability and advantages.

3.
Craniomaxillofac Trauma Reconstr ; 17(2): 104-114, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38779396

ABSTRACT

Study Design: Prospective Interventional study. Objective: To evaluate the efficiency of Matrixmidface preformed Orbital plates for three-dimensional reconstruction of orbital floor and medial wall fractures. Methods: This prospective institutional clinical study was conducted on a group of 14 patients who underwent repair of orbital floor and medial wall fracture defects using Matrixmidface Preformed Orbital plates and open reduction and internal fixation of associated fractures. The following parameters were studied preoperative and postoperative enophthalmos, hypoglobus, orbital volume; correction of diplopia, intraoperative and postoperative complications. Results: All 14 patients were males aged between 19 and 42 years. The most common mode of injury was found to be road traffic accidents (RTAs) followed by self-fall and trauma at workplace. Orbital fractures were associated with other concomitant maxillofacial fractures in 12 patients (85.7%) while 2 patients (14.3%) had pure blowout fractures. Significant improvement of enophthalmos was noted from preoperative period to 1 week, 6 weeks, and 6 months postoperatively (P value .02, .01, and .01, respectively). Out of 11 patients with preoperative hypoglobus, 5 patients (45.45%) had persistent hypoglobus in the immediate postoperative period which reduced to 4 patients (36.36%) at 6 weeks postoperatively (p value .00). The postoperative orbital volume of fractured side ranged from 20.3 cm3 to 26.76 cm3 with a mean of 23.50 cm3 ± 1.74. The mean difference between the volumes of the repaired and uninjured sides was found to be .27 cm3 ± .39 (P value .02) denoting that the reconstruction of the orbit closely approximated that of the uninjured side. Conclusions: The Matrixmidface Preformed Orbital plate provides exceptional reconstruction of the orbital blowout fracture defects and ensures satisfactory results clinically and radiographically. The plate ensures an approximate recreation of topographical anatomy of the orbit and adequately restores the orbital volume. It provides adequate correction of asymmetry, hypoglobus, enophthalmos and attempts to restore eye movements, without causing any significant postoperative complication.

SELECTION OF CITATIONS
SEARCH DETAIL
...