Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 30(12): 20659-20665, 2022 Jun 06.
Article in English | MEDLINE | ID: mdl-36224805

ABSTRACT

We fabricated a 1 × 10 PbS QD photodiode array with multiple stacked QD layers with high-resolution patterning using a customized photolithographic process. The array showed the average responsivity of 5.54 × 10-3 A/W and 1.20 × 10-2 A/W at 0 V and -1 V under 1310- nm short-wavelength infrared (SWIR) illumination. The standard deviation of the pixel responsivity was under 10%, confirming the uniformity of the fabrication process. The response time was 2.2 ± 0.13 ms, and the bandwidth was 159.1 Hz. A prototype 1310-nm SWIR imager demonstrated that the QD photodiode-based SWIR image sensor is a cost-effective and practical alternative for III-V SWIR image sensors.

2.
PLoS One ; 16(12): e0260618, 2021.
Article in English | MEDLINE | ID: mdl-34882724

ABSTRACT

PURPOSE: Immune responses for cancer cells can be altered according to genetic variation of human leukocyte antigen (HLA). Association of HLA polymorphism with risk of various cancer types is well known. However, the association between HLA and glioblastoma (GBM) remains uncertain. We sought to evaluate the association of HLA polymorphism with risk of GBM development in Koreans. MATERIALS AND METHODS: A case-control study was performed to identify the odds ratios (OR) of HLA class I and II genes for GBM. The control group consisted of 142 healthy Korean volunteers, and the GBM group was 80 patients with newly diagnosed GBM at our institution. HLA class I (-A, -B, and-C) and class II (-DR, -DQ, and-DP) genotyping was performed by high-resolution polymerase chain reaction (PCR)-sequence-based typing (PCR-SBT) methods. RESULTS: There were significantly decreased frequencies of HLA-A*26:02 (OR 0.22 CI 0.05-0.98), HLA-C*08:01 (OR 0.29 CI 0.10-0.87), and HLA-DRB1*08:03 (OR 0.32 CI 0.11-0.98), while there was significantly increased frequency of HLA-C*04:01 (OR 2.29 CI 1.05-4.97). In analysis of haplotypes, the frequency of DRB1*14:05-DQB1*05:03 was significantly decreased (OR 0.22 CI 0.05-0.98). CONCLUSION: This study suggests that genetic variations of HLA may affect GBM development in Koreans. Further investigations with larger sample sizes are needed to delineate any potential role of the HLA polymorphisms in the pathogenesis of GBM development.


Subject(s)
Asian People/genetics , Glioblastoma/genetics , HLA-A Antigens/genetics , HLA-C Antigens/genetics , HLA-DRB1 Chains/genetics , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Genetic Association Studies , Genotyping Techniques , Humans , Male , Middle Aged , Polymorphism, Single Nucleotide , Republic of Korea , Young Adult
3.
Opt Express ; 27(21): 29938-29948, 2019 Oct 14.
Article in English | MEDLINE | ID: mdl-31684249

ABSTRACT

Optical scatterfield imaging microscopy technique which has the capability of controlling scattered fields in the imaging mode is useful for quantitative nanoscale dimensional metrology that yields precise characterization of nanoscale features for semiconductor device manufacturing process control. To increase the sensitivity in the metrology using this method, it is required to optimize illumination and collection optics that enhance scatterfield signals from the nanoscale targets. Partial coherence of the optical imaging system is used not only for enhancing image quality in the traditional microscopy or lithography but also for increasing the sensitivity of the scatterfield imaging microscopy. This paper presents an empirical investigation of the effect of partial coherence on measurement sensitivity using a deep ultraviolet scatterfield imaging microscope platform that uses a 193 nm excimer laser as a source and a conjugate back focal plane as a unit for controlling partial coherence. Dimensional measurement sensitivity is assessed through analyzing scatterfield images measured at the edge area of periodic multiline structures with nominal linewidths ranging 44-80 nm on a Molybdenum Silicide (MoSi) photomask. Intensities scattered from the targets under the illuminations with various partial coherence factors and two orthogonal polarizations are assessed with respect to sensitivity coefficient. The optimization of partial coherence factor for the target dimension is discussed through the sensitivity coefficient maps.

SELECTION OF CITATIONS
SEARCH DETAIL
...