Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Gas Res ; 13(1): 29-32, 2023.
Article in English | MEDLINE | ID: mdl-35946220

ABSTRACT

Calcium ion-releasing ability of different calcium hydroxide-based pulp capping materials was comparatively evaluated in this study. Different brands of cements were taken from different manufacturers and categorized into three groups. Three different brands of Ca(OH)2 cements (Dycal, TheraCal, and Cal LC) were taken prepared by mixing and curing the cements as per the manufacturer's instructions. Consequently, ion release was measured after 7, 14, and 21 days by argon-based induction coupled plasma mass spectroscopy test. Within the limitations of this study, light-cured Ca(OH)2 cements released a higher amount of calcium ions compared with self-cured Ca(OH)2 cements. Theracal was found to be the highest light-cured calcium ion releasing materials throughout the period of 21 days. In conclusion, further clinical studies are warranted to substantiate the findings of this study.


Subject(s)
Pulp Capping and Pulpectomy Agents , Aluminum Compounds/chemistry , Argon , Calcium/chemistry , Calcium Hydroxide/chemistry , Ions , Mass Spectrometry , Oxides/chemistry
2.
J Lasers Med Sci ; 7(3): 184-191, 2016.
Article in English | MEDLINE | ID: mdl-28144440

ABSTRACT

Introduction: This in vitro study was designed to measure and compare the amount of temperature rise in the pulp chamber of the teeth exposed to different light curing units (LCU), which are being used for curing composite restorations. Methods: The study was performed in two settings; first, an in vitro and second was mimicking an in vivo situation. In the first setup of the study, three groups were formed according to the respective three light curing sources. i.e. quartz-tungsten-halogen (QTH) unit and two light-emitting diode (LED) units (second and third generations). In the in vitro setting, direct thermal emission from three light sources at 3 mm and 6 mm distances, was measured with a k-type thermocouple, and connected to a digital thermometer. For a simulation of an in vivo situation, 30 premolar teeth were used. Class I Occlusal cavity of all the teeth were prepared and they were restored with incremental curing of composite, after bonding agent application. While curing the bonding agent and composite in layers, the intrapulpal temperature rise was simultaneously measured with a k-type thermocouple. Results: The first setting of the study showed that the heat produced by irradiation with LCU was significantly less at 6 mm distance when compared to 3 mm distance. The second setting of the study showed that the rise of intrapulpal temperature was significantly less with third generation LED light cure units than with second generation LED and QTH light cure units. Conclusion: As the distance from the light source increases, less irradiation heat is produced. Third generation LED lights cause the least temperature change in the pulp chamber of single rooted teeth.

SELECTION OF CITATIONS
SEARCH DETAIL
...