Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
BMC Infect Dis ; 23(1): 617, 2023 Sep 19.
Article in English | MEDLINE | ID: mdl-37726696

ABSTRACT

BACKGROUND: Dialister pneumosintes is an anaerobic, Gram negative bacillus, found in the human oral cavity and associated with periodontitis. It has also been isolated from gastric mucosa and stool samples. Recent case reports implicate D. pneumosintes in local infection such as dental root canals, sinusitis, Lemierres syndrome and brain abscesses, as well as distal infections of the liver and lung through haematogenous spread. CASE PRESENTATION: We present a novel case of aortic graft infection and aortoenteric fistula (AEF) in a 75 year old Caucasian male, associated with D. pneumosintes bacteraemia. Microbiological evaluation of septic emboli in the lower limbs revealed other gastrointestinal flora. This suggests either AEF leading to graft infection and subsequent distal emboli and bacteraemia, or a dental origin of infection which seeded to the graft, resulting in AEF and systemic infection. To our knowledge this is the first report of D. pneumosintes associated aortic graft infection. The patient underwent surgical explantation, oversew of the aorta and placement of extra-anatomical bypass graft in conjunction with antimicrobial therapy, making a good recovery with discharge home after a 35-day hospital admission. CONCLUSION: We report a case of Dialister pneumosintes bacteraemia associated with aortic graft infection. To our knowledge, vascular graft-associated infection with D. pneumosintes has not been reported before.


Subject(s)
Bacteremia , Sepsis , Male , Humans , Aged , Aorta , Veillonellaceae , Postoperative Complications , Bacteroides
2.
Ann Vasc Surg ; 95: 184-187, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37075833

ABSTRACT

BACKGROUND: Phantom limb pain (PLP) can have devastating consequences, affecting up to 90% of amputees. PLP is associated with analgesia dependence and impaired quality of life. Mirror therapy (MT) is a novel treatment that has been applied in other pain syndromes. We prospectively evaluated MT in the management of PLP. METHODS: A prospective study of patients recruited between 2008 and 2020 who underwent unilateral major limb amputation, with a healthy contralateral limb. Participants were invited to attend weekly MT sessions. Pain in the 7 days prior to each MT session was scored on a Visual Analog Scale (VAS: 0-10 mm) and the short form McGill pain questionnaire. RESULTS: Ninety eight patients (68 males and 30 females) aged 17-89 years were recruited over 12 years. Forty four percent of patients had amputations due to peripheral vascular disease. Over an average of 2.5 sessions, the final treatment score on the VAS scale was 2.6 (standard deviation ± 3.0) with a reduction of 4.5 points on VAS score. As a comparison using the short form McGill pain questionnaire scoring system, the average final treatment score was 3.2 (± 5.0) with 91% overall improvement. CONCLUSIONS: MT is a very powerful and effective intervention for PLP. It is an exciting addition to the armory of vascular surgeons in the management of this condition.


Subject(s)
Amputees , Phantom Limb , Male , Female , Humans , Phantom Limb/diagnosis , Phantom Limb/therapy , Mirror Movement Therapy , Quality of Life , Prospective Studies , Treatment Outcome , Lower Extremity/surgery
3.
Int J Comput Assist Radiol Surg ; 17(9): 1611-1617, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35397710

ABSTRACT

PURPOSE: Multimodality imaging of the vascular system is a rapidly growing area of innovation and research, which is increasing with awareness of the dangers of ionizing radiation. Phantom models that are applicable across multiple imaging modalities facilitate testing and comparisons in pre-clinical studies of new devices. Additionally, phantom models are of benefit to surgical trainees for gaining experience with new techniques. We propose a temperature-stable, high-fidelity method for creating complex abdominal aortic aneurysm phantoms that are compatible with both radiation-based, and ultrasound-based imaging modalities, using low cost materials. METHODS: Volumetric CT data of an abdominal aortic aneurysm were acquired. Regions of interest were segmented to form a model compatible with 3D printing. The novel phantom fabrication method comprised a hybrid approach of using 3D printing of water-soluble materials to create wall-less, patient-derived vascular structures embedded within tailored tissue-mimicking materials to create realistic surrounding tissues. A non-soluble 3-D printed spine was included to provide a radiological landmark. RESULTS: The phantom was found to provide realistic appearances with intravascular ultrasound, computed tomography and transcutaneous ultrasound. Furthermore, the utility of this phantom as a training model was demonstrated during a simulated endovascular aneurysm repair procedure with image fusion. CONCLUSION: With the hybrid fabrication method demonstrated here, complex multimodality imaging patient-derived vascular phantoms can be successfully fabricated. These have potential roles in the benchtop development of emerging imaging technologies, refinement of novel minimally invasive surgical techniques and as clinical training tools.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Humans , Phantoms, Imaging , Printing, Three-Dimensional
4.
J Vasc Surg ; 71(3): 748-757, 2020 03.
Article in English | MEDLINE | ID: mdl-31477478

ABSTRACT

OBJECTIVE: A rational approach to the management of aortic aneurysm disease relies on weighing the risk of aneurysm rupture against the complications and durability of operative repair. In men, seminal studies of infrarenal aortic aneurysm disease and its endovascular management can provide a reasoned argument for the timing and modality of surgery, which is then extrapolated to the management of thoracoabdominal aortic aneurysms (TAAAs). In contrast, there is less appreciation for the natural history of TAAA disease in women and its response to therapy. METHODS: We used a retrospective cohort design of women, all men, and matched men, fit for complex endovascular thoracoabdominal aneurysm repair at two large aortic centers. We controlled for preoperative anatomic and comorbidity differences, and assessed technical success, postoperative renal dysfunction, spinal ischemia, and early mortality. Women and matched men were reassessed at follow-up for long-term durability and survival. RESULTS: Assessing women and all men undergoing complex endovascular aortic reconstruction, we demonstrate that these groups are dissimilar before the intervention with respect to comorbidities, aneurysm extent, and aneurysm size; women have a higher proportion of proximal Crawford extent 1, 2, and 3 aneurysms. Matching men and women for demographic and anatomic differences, we find persistent elevated perioperative mortality in women (16%) undergoing endovascular thoracoabdominal aneurysm repair compared with matched men (6%); however, at the 3-year follow-up, both groups have the same survival. Furthermore, women demonstrate more favorable anatomic responses to aneurysm exclusion, with good durability and greater aneurysm sac regression at follow-up, compared with matched men. CONCLUSIONS: Women and unmatched men with TAAA disease differ preoperatively with respect to aneurysm extent and comorbidities. Controlling for these differences, after complex endovascular aneurysm repair, there is increased early mortality in women compared with matched men. These observations argue for a careful risk stratification of women undergoing endovascular thoracoabdominal aneurysm treatment, balanced with women's good long-term survival and durability of endovascular aneurysm repair.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Endovascular Procedures , Aged , Aortic Aneurysm, Thoracic/mortality , Female , Humans , Male , Postoperative Complications , Retrospective Studies , Sex Factors , Survival Rate
5.
J Vasc Surg ; 68(6): 1706-1713.e1, 2018 12.
Article in English | MEDLINE | ID: mdl-29804734

ABSTRACT

OBJECTIVE: Use of three-dimensional fusion has been shown to significantly reduce radiation exposure and contrast material use in complex (fenestrated and branched) endovascular aneurysm repair (EVAR). Cydar software (CYDAR Medical, Cambridge, United Kingdom) is a cloud-based technology that can provide imaging guidance by overlaying preoperative three-dimensional vessel anatomy from computed tomography scans onto live fluoroscopy images both in hybrid operating rooms and on mobile C-arms. The aim of this study was to determine whether radiation dose reduction would occur with the addition of fusion imaging to infrarenal repair in all imaging environments. METHODS: All patients who consented to involvement in the trial and who were treated with EVAR in our center from March 2016 until April 2017 were included. A teaching session about radiation protection and Cydar fusion software use was provided to all operators before the start of the fusion group enrollment. This group was compared with a retrospective cohort of patients treated in the same center from March 2015 to March 2016, after a dedicated program of radiation awareness and reduction was introduced. Ruptured aneurysms and complex EVAR were excluded. Preoperative and perioperative characteristics were recorded, including parameters of radiation dose, such as air kerma and dose-area product. Results were expressed in median and interquartile range. RESULTS: Forty-four patients were prospectively enrolled and compared with 21 retrospective control patients. No significant differences were found in comparing sex, body mass index, and age at repair. The median operation time (wire to wire) and fluoroscopy time were 90 (75-105) minutes and 30 (22-34) minutes, respectively, without significant differences between groups (P = .56 and P = .36). Dose-area product was nonsignificantly higher in the control group, 21.7 (8.9-85.9) Gy cm2, compared with the fusion group, 12.4 (7.5-23.4) Gy cm2 (P = .10). Air kerma product was significantly higher in the control group, 142 (61-541) mGy, compared with 82 (51-115) mGy in the fusion group (P = .03). The number of digital subtraction angiography runs was significantly lower in the fusion group (8 [6-11]) compared with the control group (10 [9-14]); (P = .03). There were no significant differences in the frequency of adverse events, endoleaks, or additional procedures required. CONCLUSIONS: When it is used in simple procedures such as infrarenal aneurysm repair, image-based fusion technology is feasible both in hybrid operating rooms and on mobile systems and leads to an overall 50% reduction in radiation dose. Fusion technology should become standard of care for centers attempting to maximize radiation dose reduction, even if capital investment of a hybrid operating room is not feasible.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Computed Tomography Angiography/methods , Endovascular Procedures/methods , Imaging, Three-Dimensional/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Interventional/methods , Surgery, Computer-Assisted/methods , Aged , Aged, 80 and over , Aortography/adverse effects , Cloud Computing , Computed Tomography Angiography/adverse effects , Endovascular Procedures/adverse effects , Feasibility Studies , Female , Fluoroscopy , Humans , Imaging, Three-Dimensional/adverse effects , Male , Predictive Value of Tests , Prospective Studies , Radiation Dosage , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Radiography, Interventional/adverse effects , Retrospective Studies , Risk Factors , Surgery, Computer-Assisted/adverse effects , Treatment Outcome
6.
Vasc Med ; 23(5): 461-466, 2018 10.
Article in English | MEDLINE | ID: mdl-29806551

ABSTRACT

Fusion imaging is standard for the endovascular treatment of complex aortic aneurysms, but its role in follow up has not been explored. A critical issue is renal function deterioration over time. Renal volume has been used as a marker of renal impairment; however, it is not reproducible and remains a complex and resource-intensive procedure. The aim of this study is to determine the accuracy of a fusion-based software to automatically calculate the renal volume changes during follow up. In this study, computerized tomography (CT) scans of 16 patients who underwent complex aortic endovascular repair were analysed. Preoperative, 1-month and 1-year follow-up CT scans have been analysed using a conventional approach of semi-automatic segmentation, and a second approach with automatic segmentation. For each kidney and at each time point the percentage of change in renal volume was calculated using both techniques. After review, volume assessment was feasible for all CT scans. For the left kidney, the intraclass correlation coefficient (ICC) was 0.794 and 0.877 at 1 month and 1 year, respectively. For the right side, the ICC was 0.817 at 1 month and 0.966 at 1 year. The automated technique reliably detected a decrease in renal volume for the eight patients with occluded renal arteries during follow up. This is the first report of a fusion-based algorithm to detect changes in renal volume during postoperative surveillance using an automated process. Using this technique, the standardized assessment of renal volume could be implemented with greater ease and reproducibility and serve as a warning of potential renal impairment.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Kidney/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Renal Artery Obstruction/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Algorithms , Aortic Aneurysm, Abdominal/diagnostic imaging , Automation , Feasibility Studies , Female , Glomerular Filtration Rate , Humans , Kidney/physiopathology , Male , Organ Size , Pilot Projects , Predictive Value of Tests , Renal Artery Obstruction/etiology , Renal Artery Obstruction/physiopathology , Reproducibility of Results , Retrospective Studies , Risk Factors , Software , Time Factors , Treatment Outcome
7.
J Vasc Surg Cases ; 1(3): 197-200, 2015 Sep.
Article in English | MEDLINE | ID: mdl-31724566

ABSTRACT

We describe the management of a woman who presented with synchronous mycotic aortic aneurysms of the aortic arch in the presence of Kommerell diverticulum, the distal thoracic, and the juxtarenal aorta. A staged stent graft repair was undertaken due to rapid expansion of the aneurysms, which involved placement of multiple thoracic quadruple-fenestrated and infrarenal bifurcated stent grafts. Despite complications of an aortoesophageal fistula and transitory spinal cord ischemia, she has been managed successfully and is doing well at 36 months. This case illustrates that stent graft repair of mycotic aneurysms can offer a successful treatment option in selected patients.

8.
J Immunol ; 190(2): 794-804, 2013 Jan 15.
Article in English | MEDLINE | ID: mdl-23248262

ABSTRACT

Immune dysfunction may contribute to tumor progression in gastric cancer (GC) patients. One mechanism of immune dysfunction is the suppression of T cell activation and impairment of the efficacy of cancer immunotherapy by myeloid-derived suppressor cells (MDSCs). We assessed the phenotype and immunosuppressive function of MDSCs in GC patients. We further investigated the role of S100A8/A9 in GC and the relationship between S100A8/A9 and MDSC function. Lastly, the effect of MDSCs on survival rates and its potential as a prognostic factor in GC patients were investigated. MDSCs from PBMCs of GC patients were identified by comparing the expression of specific surface markers with PBMCs from healthy individuals. The ability of MDSCs to suppress T lymphocyte response and the effect of S100A8/A9 and RAGE blocking were tested in vitro by (autologous) MLR. GC patients had significantly more MDSCs than healthy individuals. These MDSCs suppressed both T lymphocyte proliferation and IFN-γ production and had high arginase-I expression. Levels of S100A8/A9 in plasma were higher in GC patients compared with healthy individuals, and they correlated with MDSC levels in the blood. Blocking of S100A8/A9 itself and the S100A8/A9 receptor RAGE on MDSCs from GC patients abrogated T cell effector function. We found that high levels of MDSCs correlated with more advanced cancer stage and with reduced survival (p = 0.006). S100A8/A9 has been identified as a potential target to modulate antitumor immunity by reversing MDSC-mediated immunosuppression.


Subject(s)
Calgranulin A/blood , Calgranulin B/blood , Myeloid Cells , Stomach Neoplasms/blood , Stomach Neoplasms/pathology , Antigens, CD/metabolism , Arginase/metabolism , CD11b Antigen/metabolism , Humans , Immunophenotyping , Lipopolysaccharide Receptors/metabolism , Myeloid Cells/immunology , Myeloid Cells/metabolism , Neoplasm Staging , Nitric Oxide Synthase Type II/metabolism , Phenotype , Prognosis , Stomach Neoplasms/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...