Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Indian J Crit Care Med ; 28(4): 336-342, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38585308

ABSTRACT

Aim and background: High-quality cardiopulmonary resuscitation (CPR) is associated with improved patient outcomes, but healthcare workers (HCWs) may be frequently undertrained. This study aimed to assess baseline knowledge and skills among HCWs about basic and advanced life support and the effect of simulation-based training on it. Methods: It was a single-center prospective quasi-interventional study among resident doctors and nurses at a Tertiary Center in New Delhi, India. A questionnaire-based assessment was done to assess baseline knowledge. The participants then underwent simulation-based training followed by questionnaire-based knowledge assessment and skill assessment. A repeat questionnaire-based assessment was done 6 months post-training to assess knowledge retention. Results: A total of 82 HCWs (54 doctors and 28 nurses) were enrolled. The participants scored 22.28 ± 6.06 out of 35 (63.65%) in the pre-training knowledge assessment, with low scores in post-cardiac arrest care, advanced life support, and defibrillation. After the training, there was a significant rise in scores to 28.32 ± 4.08 out of 35 (80.9%) (p < 0.01). The retention of knowledge at 6 months was 68.87% (p < 0.01). The participants scored 92.61 ± 4.75% marks in skill assessment with lower scores in chest compressions and team leadership roles. There was a positive correlation (r = 0.35) between knowledge and skills scores (p < 0.01). Conclusion: There is a progressive decrease in baseline knowledge of HCWs with the further steps in the adult chain of survival. The simulation training program had a positive impact on the knowledge of HCWs. The training programs should focus on defibrillation, advanced life support, post-cardiac arrest care, and leadership roles. How to cite this article: Agarwal A, Baitha U, Ranjan P, Swarnkar NK, Singh GP, Baidya DK, et al. Knowledge and Skills in Cardiopulmonary Resuscitation and Effect of Simulation Training on it among Healthcare Workers in a Tertiary Care Center in India. Indian J Crit Care Med 2024;28(4):336-342.

2.
3.
World J Pediatr Congenit Heart Surg ; : 21501351241227889, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38516699

ABSTRACT

Anomalous origin of a pulmonary artery branch from the aorta is a rare congenital anomaly in which one of the pulmonary arteries arises from the aorta. These patients require early surgery to prevent development of severe irreversible pulmonary arterial hypertension. Multiple techniques have been described for repair of this condition. In this report, we describe a different technique compared with previously described procedures and discuss its advantages.

6.
Transl Oncol ; 28: 101593, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36571987

ABSTRACT

The clinical utility of gallium 68 (68Ga)-PSMA PET for the diagnosis and management of prostate cancer is driven in part by radioisotope availability and production costs. This study evaluates the equivalence between the two manufacturing processes for 68Ga-PSMA: 68Ga-PSMA-cyclotron (from a solid target) and 68Ga-PSMA-generator. A prospective, single-arm, single-institution non-randomized study was conducted where 16 patients with prostate adenocarcinoma underwent PET/CTs consecutively within 12 to 48 hours with each type of manufactured 68Ga-PSMA between December 2020 and June 2021. The intraclass correlation coefficients suggested acceptable reliability in all lesion parameters (ICC > 0.70). Bland-Altman analysis demonstrated acceptable bias levels for all lesion parameters. Thereby 68Ga-cyclotron (solid target) and 68Ga-generator production methods tagged to the same PSMA ligand resulted in scans which were deemed to be equivalent in detecting PSMA+ lesions in our study. As cyclotron-produced, solid- target 68Ga can be made in large (Ci) quantities, it is a promising tool for future application in 68Ga-PSMA PET scans with the potential to decrease radiotracer production costs and increase isotope availability.

7.
Ann Pediatr Cardiol ; 16(4): 282-285, 2023.
Article in English | MEDLINE | ID: mdl-38343498

ABSTRACT

In patients with univentricular heart, the Fontan procedure is the final palliation. This is usually staged. A systemic-to-pulmonary artery shunt is performed in the presence of episodes of cyanotic spells in the neonatal period or in some patients in infancy; a bidirectional superior cardiopulmonary anastomosis is preferred early in life. This is followed by the final Fontan palliation on an elective basis later. For an effective bidirectional superior cavopulmonary anastomosis and Fontan palliation, good-sized confluent pulmonary arteries (PAs) are mandatory in addition to favorable hemodynamic data. Patients with discontinuous PAs that are small in size present a surgical challenge at initial palliation as the one described in this report.

8.
Ann Pediatr Cardiol ; 16(5): 354-359, 2023.
Article in English | MEDLINE | ID: mdl-38766445

ABSTRACT

Total cavopulmonary connection (Fontan) without using cardiopulmonary bypass (CPB) may be superior to Fontan on CPB. In the experience of many, a Fontan operation without CPB may be associated with a reduced need for inotropic support, improved outcomes in the postoperative phase including faster time to termination of mechanical ventilatory support, reduced intensive care unit stay, lower volume of pleural and peritoneal effusions, and decreased hospital stay, thereby rendering it more cost-effective. However, the operation is technically more difficult to perform than Fontan on CPB and requires significant modifications of surgical technique and alteration in overall management strategy. In this article, an alternative technique of performing total cavopulmonary connection without CPB is described. Its advantages are briefly discussed.

9.
Ann Pediatr Cardiol ; 14(3): 350-355, 2021.
Article in English | MEDLINE | ID: mdl-34667407

ABSTRACT

BACKGROUND: Pulmonary vascular resistance, an important determinant of shunting across ventricular septal defects (VSD), rises at both extremes of lung volume. AIMS: We sought to determine the effect of changes in tidal volumes (VT) on pulmonary blood flow (Qp), systemic blood flow (Qs), and shunt (Qp/Qs) in children with VSD. SETTING: Single-center teaching hospital. DESIGN: Prospective observational study. METHODS: Thirty children with a mean age of 11.8 ± 5 months undergoing surgical closure of VSD were studied. Hemodynamics and shunt-related parameters were assessed using transthoracic echocardiography measured at three different VT i.e. 10, 8, and 6-ml/kg keeping the minute ventilation constant. RESULTS: Reduction in VT from 10 to 8 to 6 ml/kg led to a reduction in gradient across VSD measuring 23.5, 20 and 13 mmHg respectively (P < 0.001). Similarly, right ventricluar outflow tract (RVOT) diameter, RVOT velocity time integral, Qp (57.3 ± 18.1, 50.6 ± 16.9, 39.9 ± 14.7 mL; P < 0.001), Qs (24.1 ± 10.4, 20.0 ± 8.7, 15.3 ± 6.9 mL; P < 0.001) and peak airway pressure (17.2 ± 1.5, 15.8 ± 1.3, 14.5 ± 1.2 cmHg; P < 0.001) showed progressive decline with decreasing VT from 10 to 8 to 6 ml/kg, respectively. However, Qp/Qs (2.4 ± 0.4, 2.6 ± 0.4, 2.6 ± 0.4) demonstrated a minor increasing trend. CONCLUSION: Lower VT reduces the gradient across VSD, the pulmonary blood flow, and the peak airway pressure. Hence, ventilation with lower VT and higher respiratory rate maintaining adequate minute ventilation might be preferable in children with VSD. Further studies are required to confirm the findings of this pilot study.

10.
Ann Card Anaesth ; 24(2): 263-265, 2021.
Article in English | MEDLINE | ID: mdl-33884992

ABSTRACT

Pain emanating from pleurodesis is significantly distressing and presents an important management concern. Despite encouraging evidence on the application of fascial plane blocks for cardiothoracic surgery, the literature on the use of erector spinae block for pleurodesis remains scarce. We describe a case of bilateral recurrent pleural effusion following congenital heart surgery where erector spinae block was employed as an analgesic technique for pleurodesis. Finally, we discuss its regional analgesic effects in comparison to the conventional intravenous/systemic analgesia in a cross over fashion.


Subject(s)
Arterial Switch Operation , Nerve Block , Analgesics/therapeutic use , Humans , Pain, Postoperative/drug therapy , Pleurodesis
13.
Ann Card Anaesth ; 23(2): 221-223, 2020.
Article in English | MEDLINE | ID: mdl-32275041

ABSTRACT

Erector spinae plane block has been described to manage post-thoracotomy pain. It is a simple block and shown to be provide effective analgesia. In single shot blocks opioid supplementation may be required to manage pain after the effect of local anesthetic wears off. In this case, we describe a case of chest wall tumor excision in a child who received clonidine in addition to local anesthetic for the erector spinae plane block. This provided long lasting and effective postoperative analgesia and may be considered to prolong the analgesia achieved with erector spinae plane block.


Subject(s)
Analgesics/therapeutic use , Clonidine/therapeutic use , Nerve Block/methods , Pain, Postoperative/drug therapy , Thoracic Neoplasms/surgery , Thoracotomy/methods , Child, Preschool , Female , Humans , Thoracic Wall/surgery
14.
Ann Card Anaesth ; 23(1): 82-86, 2020.
Article in English | MEDLINE | ID: mdl-31929254

ABSTRACT

The association of Hemophilia A and ruptured aneurysm of sinus of valsalva (RSOV) has never been reported to the best of our knowledge. We report the case of a 29-year-old male patient with Hemophilia type A who presented with a RSOV into right atrium (RA). The patient underwent device closure off the RSOV and received Factor VIII infusions to decrease blood loss. The peri-procedural management is being presented in this case report.


Subject(s)
Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Aortic Rupture/complications , Aortic Rupture/diagnostic imaging , Echocardiography, Transesophageal/methods , Hemophilia A/complications , Sinus of Valsalva/diagnostic imaging , Adult , Aortic Aneurysm/therapy , Aortic Rupture/therapy , Humans , Male , Septal Occluder Device , Sinus of Valsalva/surgery
15.
J Cardiothorac Vasc Anesth ; 34(1): 58-64, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31473114

ABSTRACT

BACKGROUND: Augmentation of coronary artery flow by surgical grafting increases coronary sinus blood flow (CSBF), which can be quantified on transesophageal echocardiography (TEE). However, transit time flowmetry (TTF) technology remains the most used intraoperative technique for coronary artery graft assessment. The purpose of the present pilot study was to evaluate the predictive value of TEE-based CSBF estimation for identifying favorable TTF graft measurements. DESIGN: Prospective observational study. SETTING: Single university hospital. PATIENTS: Forty patients undergoing triple vessel coronary artery bypass grafting. MEASUREMENTS AND MAIN RESULTS: CSBF was assessed on TEE examination before and after revascularization, estimating the percentage increase in CSBF (∆CSBF). Postoperative TTF graft measurements were averaged to compute mean diastolic filling (DF) and pulsatility index (PI). Subjects were grouped based on favorable (PI ≤ 3, DF ≥ 50%) and unfavorable (PI > 3, DF < 50%) parameters. The group with PI ≤ 3 (n = 32) had significantly higher ∆CSBF compared with the group with PI > 3 (n = 8) (38.22% ± 12.05%, 13.75% ± 3.37%, p < 0.001). ∆CSBF was higher in the DF ≥ 50% group (n = 35) (36.40 ± 12.99) in contrast to DF < 50% group (n = 5) (11.80 ± 2.59%). A strong negative and significantly positive correlation was observed between ∆CSBF with PI, DF (r = -0.903, 0.571, respectively, p < 0.001). A ∆CSBF ≥15.5% was found to predict a mean PI ≤ 3 and DF ≥ 50% with sensitivity and specificity of 100% and 62.5% for PI and 100% and 100% for DF. A ∆CSBF ≥19% demonstrated a sensitivity and specificity of 100% and 100%, 100% and 91.4% for prediction of PI ≤ 3 and DF ≥ 50%, respectively. CONCLUSION: TEE-based demonstration of an augmented CSBF can ensure favorable TTF graft parameters, guiding the adequacy of surgical revascularization.


Subject(s)
Coronary Sinus , Blood Flow Velocity , Coronary Artery Bypass , Coronary Circulation , Coronary Sinus/diagnostic imaging , Echocardiography, Transesophageal , Humans , Pilot Projects , Vascular Patency
19.
J Cardiovasc Imaging ; 27(1): 24-33, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30701713

ABSTRACT

BACKGROUND: Tricuspid annular plane systolic excursion (TAPSE) has become a popular tool for assessing right ventricular (RV) systolic function because of its ease of application. TAPSE using transesophageal echocardiography (TEE) is limited by alignment with the lateral wall of the RV. Modified TAPSE (m-TAPSE) is a novel method for measuring TAPSE. m-TAPSE is the difference in the 'apical to lateral tricuspid annulus distance' during diastole and systole. The aim of the present study was to compare prospectively m-TAPSE with the most commonly used parameter TAPSE and near-gold standard 2D echocardiographic parameter RV fractional area change (RV FAC). METHODS: We conducted a prospective observational study of 125 consecutive patients undergoing coronary artery bypass graft surgery in a single tertiary care center. Post-anesthetic induction TAPSE was recorded using transthoracic echocardiography (TTE). m-TAPSE was recorded using TEE in the mid-esophageal four-chamber view. RV FAC was also assessed using TEE. m-TAPSE < 16 mm, TAPSE < 16 mm and RV FAC < 35% were taken as cut-offs for RV systolic dysfunction. Correlations were assessed using the Pearson correlation coefficient. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using 2 × 2 cross table. RESULTS: m-TAPSE was significantly correlated with TAPSE (r = 0.797, p < 0.001). Similarly, a significant correlation was observed between m-TAPSE and RV FAC (r = 0.602, p < 0.001). The sensitivity, specificity, PPV, NPV, and accuracy of m-TAPSE were 100%, 98.3%, 80%, 100% and 98.4%, respectively. CONCLUSIONS: m-TAPSE correlated well with both RV FAC and TAPSE. Therefore, m-TAPSE can be considered an easily measurable alternative parameter for evaluating RV systolic function in a busy intraoperative setting.

SELECTION OF CITATIONS
SEARCH DETAIL
...