ABSTRACT

AIMS: While hormonal assays are commonly used for thyroid function assessment, Doppler sonography provides valuable information on vascularization and blood flow. This study aimed to examine the potential associations between Doppler parameters and clinical characteristics of hypothyroid patients, such as the autoimmune nature of the disease and adequacy of LT4 replacement. METHODS: A total of 338 patients with hypothyroidism, primarily caused by autoimmune thyroiditis (AT), were enrolled in this study. Exclusion criteria comprised specific medical conditions, medication history, and nodular abnormalities of the thyroid gland. Patient demographics (age, sex, BMI), treatment parameters (LT4 daily dose), and thyroid hormone levels (TSH, fT4) were recorded. RESULTS: Among the enrolled patients, 85.2% had autoimmune thyroiditis. Suboptimal levothyroxine (LT4) replacement was observed in 20.1% of patients at the time of enrollment. Patients with autoimmune thyroiditis had increased elastography ratios compared to those without autoimmune disease and present a positive association of elastography ratios with vascularity. In patients without autoimmune thyroiditis, those with suboptimal LT4 replacement had lower total thyroid volume. Patients with suboptimal LT4 replacement had higher peak systolic velocity (PSV) and end-diastolic velocity (EDV) in the inferior thyroid artery and lower resistive index (RI). The severity of hypothyroidism, as indicated by LT4 dose/body mass index (BMI), was negatively correlated with thyroid volume and EDV values of superior and inferior thyroid arteries. PSV of the inferior thyroid artery can predict suboptimal LT4 replacement (sensitivity 81.8%, specificity 42%). CONCLUSIONS: In situations where obtaining blood tests may be challenging, utilizing color Doppler ultrasound can serve as an alternative method to assess treatment responses and identify patients who require further hormonal examinations.

2.
J BUON ; 26(1): 243-249, 2021.
Article in English | MEDLINE | ID: mdl-33721458

ABSTRACT

PURPOSE: In this study we evaluated the day to day prostate displacement during radiation therapy by using implanted radiopaque fiducials and daily image guided position verification. METHODS: The data of 10 patients that received radiation therapy to the prostate were analyzed. Three fiducial markers were implanted in the prostate before treatment initiation for everyday verification of the target's position. Daily X ray images (kilovolt/KV films) of the pelvis were acquired for verification and were matched with baseline images produced during treatment preparation using bony structures and fiducials as landmarks. We calculated the mean difference between the two methods and the prostate displacement derived from these measurements. RESULTS: A total of 208 KV films were obtained. Our results showed a non-uniform prostate motion, with most of the displacements observed in the caudal direction followed by anterior, posterior, cranial, right and left. The mean target motion in each of the above directions was 3.5 mm, 3.5 mm, 3.3 mm, 3.9 mm, 2 mm and 2.4 mm. Based on the cumulative frequency of the target's displacement, a margin of 8 mm, 7mm, 5 mm, 4 mm, 9 mm and 7 mm in the anterior, posterior, left, right, cranial and caudal direction respectively would account for 95% of prostate's motion, provided that every day KV image guidance is performed. CONCLUSION: A non-isotopic margin of 8 mm, 7mm, 5 mm, 4 mm, 9 mm and 7 mm around the prostate can be considered safe for treatment delivery.


Subject(s)
Fiducial Markers/standards , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Humans , Male
3.
J Cancer ; 11(5): 1008-1016, 2020.
Article in English | MEDLINE | ID: mdl-31956347

ABSTRACT

Background: Prostate cancer is considered to be highly sensitive to changes in radiation therapy dose per fraction, specifically to hypofractionation. An increase in the fractionation dose could cause a higher increase to the prostate than to the normal tissues leading to better disease control with less toxicity. Here we present the results of a randomized trial comparing mild hypofractionation to conventional fractionation after a median of 3,6 years follow up. Patients and Methods: 139 patients were randomized to receive either hypofractionated radiotherapy with 2,25 Gy/fr to a total of 72 Gy (arm 1) or conventionally fractionated treatment with 2Gy/fr to a total of 74 Gy (arm 2). 72 patients were assigned to arm 1 and 67 to arm 2. Results: After a median follow up of 3,6 years, 23 patients (31,9%) from arm 1 developed grade≥ 2 acute genitourinary toxicity and 21 (31,3%) from arm 2 (p=0,79). The corresponding values from gastrointestinal were 15 (20,8%) and 12 (17,9%) (p=0,6). For late toxicity from GU, 8 patients (11,1%) developed grade≥ 2 symptoms in arm 1 and 7 (10,4%) in arm 2 (p=0,92). late GI toxicity grade≥ 2 was observed in 8 (11,1%) patients in arm 1 and 8 (11,9%) in arm 2 (p=0,88). In multivariate analysis, hormone therapy was significantly associated with late GI events, while acute toxicity from both GU and GI was a prognostic factor of late adverse reaction. Conclusion: No difference in the toxicity profile could be identified between hypofractionation and conventional fractionation. Our schedule of 2,25Gy/fr seems safe and tolerable by the patients with acceptable rates of acute and late toxicity.

4.
J Cancer ; 10(25): 6217-6224, 2019.
Article in English | MEDLINE | ID: mdl-31772654

ABSTRACT

Background: Prostate cancer is considered to have a special biology which could affect the radiation therapy result based on the selected fractionation scheme. We present the preliminary results of a randomized trial comparing conventionally and hypofractionated radiation therapy for prostate cancer. Methods: Patients included in the study had localized prostate cancer (cT1c-T3bN0M0) and were randomly assigned to mild hypofractionated (72 Gy in 32 fractions, arm1) or conventionally fractionated (74 Gy in 37 fractions, arm2) radiation therapy treatment with Volumetric Arc Therapy technique. The treatment was delivered only to the prostate with or without the seminal vesicles according to physician's discretion and hormone therapy was optional according to the disease stage and comorbidities. Here we present the preliminary results of acute toxicity from the gastrointestinal (GI) and genitourinary (GU) system. Results: Between 2015 and 2016, 139 patients were enrolled. 67 patients were treated with conventional fractionation and 72 were treated with hypofractionation. Grade≥ 2 toxicity from GU and GI was observed in 23 and 21 patients (31,9% vs 31,3%, p=0,79) and 15 and 12 (20,8% vs 17,9%, p=0,6) for arm1 and arm2 respectively. No statistically significant differences were observed between arms in the incidence of early toxicity. There was no correlation observed between patient characteristics and toxicity from either GU or GI. Conclusions: Hypofractionated radiotherapy appears to be equally tolerated compared to conventional fractionation in the early setting. Longer follow up is needed to assess the late toxicity profile of the patients and any potential differences between the control and experimental arm.