Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(4): e0302274, 2024.
Article in English | MEDLINE | ID: mdl-38662796

ABSTRACT

In recent years, immune checkpoint inhibitors have proved immense clinical progression in the treatment of certain cancers. The efficacy of immune checkpoint inhibitors is correlated with mismatch repair system deficiency and is exceptionally administered based exclusively on this biological mechanism independent of the cancer type. The promising effect of immune checkpoint inhibitors has left an increasing demand for analytical tools evaluating the mismatch repair status. The analysis of microsatellite instability (MSI), reflecting an indirect but objective manner the inactivation of the mismatch repair system, plays several roles in clinical practice and, therefore, its evaluation is of high relevance. Analysis of MSI by PCR followed by fragment analysis on capillary electrophoresis remains the gold standard method for detection of a deficient mismatch repair system and thereby treatment with immune checkpoint inhibitors. Novel technologies have been applied and concepts such as tumor mutation burden have been introduced. However, to date, most of these technologies require high costs or the need of matched non-tumor tissue as internal comparator. In this study, we present a novel, one-instrument, fast, and objective method for the detection of MSI (MicroSight® MSI 1-step HRM Analysis), which does not depend on the use of matched non-tumor tissue. The assay analyzes five well-described mononucleotide microsatellite sequences by real-time PCR followed by high-resolution melt and evaluates microsatellite length variations via PCR product melting profiles. The assay was evaluated using two different patient cohorts and evaluation included several DNA extraction methodologies, two different PCR platforms, and an inter-laboratory ring study. The MicroSight® MSI assay showed a high repeatability regardless of DNA extraction method and PCR platform, and a 100% agreement of the MSI status with PCR fragment analysis methods applied as clinical comparator.


Subject(s)
Microsatellite Instability , Humans , DNA Mismatch Repair/genetics , Real-Time Polymerase Chain Reaction/methods , Female , Male , Microsatellite Repeats/genetics
2.
Nat Commun ; 14(1): 5153, 2023 08 24.
Article in English | MEDLINE | ID: mdl-37620381

ABSTRACT

DNA methylation is important for gene expression and alterations in DNA methylation are involved in the development and progression of cancer and other major diseases. Analysis of DNA methylation patterns has until now been dependent on either a chemical or an enzymatic pre-treatment, which are both time consuming procedures and potentially biased due to incomplete treatment. We present a qPCR technology, EpiDirect®, that allows for direct PCR quantification of DNA methylations using untreated DNA. EpiDirect® is based on the ability of Intercalating Nucleic Acids (INA®) to differentiate between methylated and unmethylated cytosines in a special primer design. With this technology, we develop an assay to analyze the methylation status of a region of the MGMT promoter used in treatment selection and prognosis of glioblastoma patients. We compare the assay to two bisulfite-relying, methyl-specific PCR assays in a study involving 42 brain tumor FFPE samples, revealing high sensitivity, specificity, and the clinical utility of the method.


Subject(s)
Polymerase Chain Reaction , Polymerase Chain Reaction/instrumentation , Polymerase Chain Reaction/methods , DNA/metabolism , DNA Methylation , Temperature , Oligonucleotides/metabolism , CpG Islands
3.
PLoS One ; 18(2): e0281558, 2023.
Article in English | MEDLINE | ID: mdl-36758042

ABSTRACT

Mutations in BRAF exon 15 lead to conformational changes in its activation loops, resulting in constitutively active BRAF proteins which are implicated in the development of several human cancer types. Different BRAF inhibitors have been developed and introduced in clinical practice. Identification of BRAF mutations influences the clinical evaluation, treatment, progression and for that reason a sensitive and specific identification of BRAF mutations is on request from the clinic. Here we present the SensiScreen® FFPE BRAF qPCR Assay that uses a novel real-time PCR-based method for BRAF mutation detection based on PentaBases proprietary DNA analogue technology designed to work on standard real-time PCR instruments. The SensiScreen® FFPE BRAF qPCR Assay displays high sensitivity, specificity, fast and easy-to-use. The SensiScreen® FFPE BRAF qPCR Assay was validated on two different FFPE tumour biopsy cohorts, one cohort included malignant melanoma patients previously analyzed by the Cobas® 4800 BRAF V600 Mutation Test, and one cohort from colorectal cancer patients previously analyzed by mutant-enriched PCR and direct sequencing. All BRAF mutant malignant melanoma patients were confirmed with the SensiScreen® FFPE BRAF qPCR Assay and additional four new mutations in the malignant melanoma cohort were identified. All the previously identified BRAF mutations in the colorectal cancer patients were confirmed, and additional three new mutations not identified with direct sequencing were detected. Also, one new BRAF mutation not previously identified with ME-PCR was found. Furthermore, the SensiScreen® FFPE BRAF qPCR Assay identified the specific change in the amino acid. The SensiScreen® FFPE BRAF qPCR Assay will contribute to a more specific, time and cost saving approach to better identify and characterize mutations in patients affected by cancer, and consequently permits a better BRAF characterization that is fundamental for therapy decision.


Subject(s)
Colorectal Neoplasms , Melanoma , Humans , Proto-Oncogene Proteins B-raf/genetics , DNA Mutational Analysis/methods , Melanoma/metabolism , Mutation , Real-Time Polymerase Chain Reaction/methods , Colorectal Neoplasms/genetics , Melanoma, Cutaneous Malignant
4.
Microbiol Spectr ; 10(5): e0142222, 2022 10 26.
Article in English | MEDLINE | ID: mdl-36129278

ABSTRACT

We examined the detection rate of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using reverse transcription-PCR (RT-PCR) of side-by-side saliva and oropharyngeal swab (OPS) samples from 639 symptomatic and asymptomatic subjects, of which 47 subjects were found to be positive for SARS-CoV-2 in the OPS or saliva sample or both. It was found that the detection rate (93.6% for both OPS and saliva) as well as the sensitivity and specificity were comparable between the two sampling methods in this cohort. The sensitivity was 0.932 (95% confidence interval [CI], 0.818 to 0.977) and the specificity was 0.995 (95% CI, 0.985 to 0.998), both for saliva when OPS sampling was used as the reference and for OPS when saliva was used as the reference. Furthermore, the Cohen's kappa value was 0.926 (95% CI, 0.868 to 0.985), indicating strong agreement between the two sampling methods. In addition, the viral RNA stability in pure saliva and saliva mixed with preservation buffers was examined following storage at room temperature and at 4°C. It was found that pure saliva kept the viral RNA stable for 9 days at both temperatures and that the type of preservation buffer can either enhance or reduce the stability of the RNA. We conclude that self-administered saliva sampling is an attractive alternative to oropharyngeal swabbing for SARS-CoV-2 detection, and it might be useful in large-scale testing. IMPORTANCE It is not inconceivable that we will witness recurring surges of COVID-19 before the pandemic finally recedes. It is therefore still relevant to look for feasible, simple, and flexible screening methods so that schools, workplaces, and communities in general can avoid lockdowns. In this work, we analyzed two different sampling methods: oropharyngeal swabs and saliva collection. Oropharyngeal swabs must be collected by trained health personnel at clinics, whereas self-assisted saliva collection can be performed at any given location. It was found that the two sampling methods were comparable. Saliva sampling is a simple method that allows easy mass testing using minimal resources from the existing health care system, and this method may therefore prove to be an effective tool for containing the COVID-19 pandemic.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , COVID-19/diagnosis , COVID-19 Testing , Saliva , RNA, Viral , Communicable Disease Control , Specimen Handling/methods
5.
Sci Rep ; 12(1): 13069, 2022 07 29.
Article in English | MEDLINE | ID: mdl-35906388

ABSTRACT

Reverse transcription quantitative PCR (RT-qPCR) assays are gold standard in diagnosing SARS-CoV-2 infection and play a major role in viral subtyping for rapid detection and monitoring of important mutations, containing the spread of new virus variants. We wanted to compare RT-qPCR melting curve analysis assays to Sanger Sequencing for detection of variants within the SARS-CoV-2 spike glycoprotein and examined their sensitivity and specificity. Samples positive for SARS-CoV-2 (n = 663 + 82) were subtyped using both Sanger sequencing and five RT-qPCR melting curve analysis assays specific for the mutations N501Y, P681H, E484K, K417N/T, and N439K. The results of the two methods were compared. The training cohort and the clinical validation cohort showed equally, or significantly better sensitivity of the assays compared to the Sanger sequencing. The agreement of the Sanger sequencing and the assays ranged from 92.6 to 100% for the training cohort and 99.4-100% for the clinical validation. The sensitivity, specificity, and turn-around time of the RT-qPCR melting curve analysis assays are well-suited for clinical monitoring of VOCs, making the assays an important tool in contact tracing and risk stratification. Furthermore, the assays were able to indicate the presence of new mutations in the complementary sequence to the mutation-specific probes.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/genetics , Humans , Mutation , Reverse Transcription , SARS-CoV-2/genetics , Sensitivity and Specificity
6.
Nat Commun ; 12(1): 5089, 2021 08 24.
Article in English | MEDLINE | ID: mdl-34429424

ABSTRACT

The current nucleic acid signal amplification methods for SARS-CoV-2 RNA detection heavily rely on the functions of biological enzymes which imposes stringent transportation and storage conditions, high cost and global supply shortages. Here, a non-enzymatic whole genome detection method based on a simple isothermal signal amplification approach is developed for rapid detection of SARS-CoV-2 RNA and potentially any types of nucleic acids regardless of their size. The assay, termed non-enzymatic isothermal strand displacement and amplification (NISDA), is able to quantify 10 RNA copies.µL-1. In 164 clinical oropharyngeal RNA samples, NISDA assay is 100 % specific, and it is 96.77% and 100% sensitive when setting up in the laboratory and hospital, respectively. The NISDA assay does not require RNA reverse-transcription step and is fast (<30 min), affordable, highly robust at room temperature (>1 month), isothermal (42 °C) and user-friendly, making it an excellent assay for broad-based testing.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Nucleic Acid Amplification Techniques/methods , RNA, Viral/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , COVID-19/virology , COVID-19 Testing , Humans , RNA, Viral/genetics , Recombination, Genetic
7.
PLoS One ; 16(6): e0253687, 2021.
Article in English | MEDLINE | ID: mdl-34166445

ABSTRACT

BACKGROUND: A major perspective for the use of circulating tumor DNA (ctDNA) in the clinical setting of non-small cell lung cancer (NSCLC) is expected as predictive factor for resistance and response to EGFR TKI therapy and, especially, as a non-invasive alternative to tissue biopsy. However, ctDNA is both highly fragmented and mostly low concentrated in plasma and serum. On this basis, it is important to use a platform characterized by high sensitivity and linear performance in the low concentration range. This motivated us to evaluate the newly developed and commercially available SensiScreen® EGFR Liquid assay platform (PentaBase) with regard to sensitivity, linearity, repeatability and accuracy and finally to compare it to our already implemented methods. The validation was made in three independent European laboratories using two cohorts on a total of 68 unique liquid biopsies. RESULTS: Using artificial samples containing 1600 copies of WT DNA spiked with 50% - 0.1% of mutant copies across a seven-log dilution scale, we assessed the sensitivity, linearity, repeatability and accuracy for the p.T790M, p.L858R and exon 19 deletion assays of the SensiScreen® EGFR Liquid assay platform. The lowest value detectable ranged from 0.5% to 0.1% with R2≥0,97 indicating good linearity. High PCR efficiency was shown for all three assays. In 102 single PCRs each containing theoretical one copy of the mutant at initiating, assays showed repeatable positivity in 75.5% - 80.4% of reactions. At low ctDNA levels, as in plasma, the SensiScreen® EGFR Liquid assay platform showed better sensitivity than the Therascreen® EGFR platform (Qiagen) and equal performance to the ctEGFR Mutation Detection Kit (EntroGen) and the IOT® Oncomine cell-free nucleic acids assay (Thermo Fisher Scientific) with 100% concordance at the sequence level. CONCLUSION: For profiling clinical plasma samples, characterized by low ctDNA abundance, the SensiScreen® EGFR Liquid assay is able to identify down to 1 copy of mutant alleles and with its high sensitivity, linearity and accuracy it may be a competitive platform of choice.


Subject(s)
Carcinoma, Non-Small-Cell Lung/genetics , Circulating Tumor DNA/genetics , Lung Neoplasms/genetics , Mutation , Neoplasm Proteins/genetics , Adult , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/blood , Cell Line, Tumor , Circulating Tumor DNA/blood , DNA Mutational Analysis , ErbB Receptors/blood , ErbB Receptors/genetics , Female , Humans , Liquid Biopsy , Lung Neoplasms/blood , Male , Middle Aged , Neoplasm Proteins/blood
8.
PLoS One ; 12(6): e0178027, 2017.
Article in English | MEDLINE | ID: mdl-28636636

ABSTRACT

Activating mutations in codon 12 and codon 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) gene are implicated in the development of several human cancer types and influence their clinical evaluation, treatment and prognosis. Numerous different methods for KRAS genotyping are currently available displaying a wide range of sensitivities, time to answer and requirements for laboratory equipment and user skills. Here we present SensiScreen® KRAS exon 2 simplex and multiplex CE IVD assays, that use a novel real-time PCR-based method for KRAS mutation detection based on PentaBase's proprietary DNA analogue technology and designed to work on standard real-time PCR instruments. By means of the included BaseBlocker™ technology, we show that SensiScreen® specifically amplifies the mutated alleles of interest with no or highly subdued amplification of the wild type allele. Furthermore, serial dilutions of mutant DNA in a wild type background demonstrate that all SensiScreen® assays display a limit of detection that falls within the range of 0.25-1%. Finally, in three different colorectal cancer patient populations, SensiScreen® assays confirmed the KRAS genotype previously determined by commonly used methods for KRAS mutation testing, and notably, in two of the populations, SensiScreen® identified additional mutant positive cases not detected by common methods.


Subject(s)
Biological Assay/methods , Colorectal Neoplasms/diagnosis , Exons , Multiplex Polymerase Chain Reaction/methods , Mutation/genetics , Proto-Oncogene Proteins p21(ras)/genetics , Real-Time Polymerase Chain Reaction/methods , Cohort Studies , Colorectal Neoplasms/genetics , DNA, Neoplasm/genetics , Genotype , Humans , Tumor Cells, Cultured
SELECTION OF CITATIONS
SEARCH DETAIL
...