Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 4837, 2024 02 28.
Article in English | MEDLINE | ID: mdl-38418657

ABSTRACT

The EOS™2D/3D system is a low-dose, 3D imaging system that utilizes two perpendicular X-ray beams to create simultaneous frontal and lateral images of the body. This is a useful modality to assess spinal pathologies. However, due to the slow imaging acquisition time up to 25 s, motion artifacts (MA) frequently occur. These artifacts may not be distinguishable from pathological findings, such as scoliosis, and may impair the diagnostic process. The aim of this study was to design a method to detect MA in EOS X-ray. We retrospectively analyzed EOS imaging from 40 patients wearing a radiopaque reference device during imaging. We drew a straight vertical line along the reference device. We measured deviations from it to quantify MA, presenting these findings through descriptive statistics. For a subset of patients with high MA, acquisitions were repeated after giving specific instructions to stand still. For these patients, we compared MA between the two acquisitions. In our study, a substantial proportion of patients exhibited MA ≥ 1 mm, with 80% in frontal projections and 87.9% in lateral projections. In the subjects who received a second acquisition, MA was significantly lower in the second images. Our method allows for a precise detection of MA on EOS images through a simple, yet reliable solution. Our method may improve the reliability of spine measurements, and reduce the risk of wrong diagnosis due to low imaging quality.


Subject(s)
Artifacts , Imaging, Three-Dimensional , Humans , X-Rays , Retrospective Studies , Reproducibility of Results , Radiography , Imaging, Three-Dimensional/methods
2.
Sci Rep ; 13(1): 7245, 2023 05 04.
Article in English | MEDLINE | ID: mdl-37142669

ABSTRACT

The aim of this exploratory study was the assessment of the metabolic profiles of persons with complete spinal cord injury (SCI) in three region-of-interests (pons, cerebellar vermis, and cerebellar hemisphere), with magnetic resonance spectroscopy, and their correlations to clinical scores. Group differences and association between metabolic and clinical scores were examined. Fifteen people with chronic SCI (cSCI), five people with subacute SCI (sSCI) and fourteen healthy controls were included. Group comparison between cSCI and HC showed lower total N-acetyl-aspartate (tNAA) in the pons (p = 0.04) and higher glutathione (GSH) in the cerebellar vermis (p = 0.02). Choline levels in the cerebellar hemisphere were different between cSCI and HC (p = 0.02) and sSCI and HC (p = 0.02). A correlation was reported for choline containing compounds (tCho) to clinical scores in the pons (rho = - 0.55, p = 0.01). tNAA to total creatine (tNAA/tCr ratio) correlated to clinical scores in the cerebellar vermis (rho = 0.61, p = 0.004) and GSH correlated to the independence score in the cerebellar hemisphere (rho = 0.56, p = 0.01). The correlation of tNAA, tCr, tCho and GSH to clinical scores might be indicators on how well the CNS copes with the post-traumatic remodeling and might be further examined as outcome markers.


Subject(s)
Cerebellum , Spinal Cord Injuries , Humans , Proton Magnetic Resonance Spectroscopy , Cerebellum/metabolism , Spinal Cord Injuries/metabolism , Pons/diagnostic imaging , Pons/metabolism , Creatine/metabolism , Metabolome , Choline/metabolism , Receptors, Antigen, T-Cell/metabolism , Aspartic Acid/metabolism
3.
NMR Biomed ; 36(3): e4856, 2023 03.
Article in English | MEDLINE | ID: mdl-36285630

ABSTRACT

Diffusion kurtosis imaging (DKI) is applied to gain insights into the microstructural organization of brain tissues. However, the reproducibility of DKI outside brain white matter, particularly in combination with advanced estimation to remedy its noise sensitivity, remains poorly characterized. Therefore, in this study, we investigated the variability and reliability of DKI metrics while correcting implausible values with a fit method called mean kurtosis (MK)-Curve. A total of 10 volunteers (four women; age: 41.4 ± 9.6 years) were included and underwent two MRI examinations of the brain. The images were acquired on a clinical 3-T scanner and included a T1-weighted image and a diffusion sequence with multiple diffusion weightings suitable for DKI. Region of interest analysis of common kurtosis and tensor metrics derived with the MK-Curve DKI fit was performed, including intraclass correlation (ICC) and Bland-Altman (BA) plot statistics. A p value of less than 0.05 was considered statistically significant. The analyses showed good to excellent agreement of both kurtosis tensor- and diffusion tensor-derived MK-Curve-corrected metrics (ICC values: 0.77-0.98 and 0.87-0.98, respectively), with the exception of two DKI-derived metrics (axial kurtosis in the cortex: ICC = 0.68, and radial kurtosis in deep gray matter: ICC = 0.544). Non-MK-Curve-corrected kurtosis tensor-derived metrics ranged from 0.01 to 0.52 and diffusion tensor-derived metrics from 0.06 to 0.66, indicating poor to moderate reliability. No structural bias was observed in the BA plots for any of the diffusion metrics. In conclusion, MK-Curve-corrected DKI metrics of the human brain can be reliably acquired in white and gray matter at 3 T and DKI metrics have good to excellent agreement in a test-retest setting.


Subject(s)
Diffusion Tensor Imaging , White Matter , Humans , Female , Adult , Middle Aged , Reproducibility of Results , Diffusion Tensor Imaging/methods , Brain/diagnostic imaging , Magnetic Resonance Imaging , White Matter/diagnostic imaging , Diffusion Magnetic Resonance Imaging
4.
Sci Rep ; 12(1): 20874, 2022 12 03.
Article in English | MEDLINE | ID: mdl-36463248

ABSTRACT

After spinal cord injury (SCI), reorganization processes and changes in brain connectivity occur. Besides the sensorimotor cortex, the subcortical areas are strongly involved in motion and executive control. This exploratory study focusses on the cerebellum and vermis. Resting-state functional magnetic resonance imaging (fMRI) was performed. Between-group differences were computed using analysis of covariance and post-hoc tests for the seed-based connectivity measure with vermis and cerebellum as regions of interest. Twenty participants with complete SCI (five subacute SCI, 15 with chronic SCI) and 14 healthy controls (HC) were included. Functional connectivity (FC) was lower in all subjects with SCI compared with HC in vermis IX, right superior frontal gyrus (pFDR = 0.008) and right lateral occipital cortex (pFDR = 0.036). In addition, functional connectivity was lower in participants with chronic SCI compared with subacute SCI in bilateral cerebellar crus I, left precentral- and middle frontal gyrus (pFDR = 0.001). Furthermore, higher amplitude of low-frequency fluctuations (ALFF) was found in the left thalamus in individuals with subacute SCI (pFDR = 0.002). Reduced FC in SCI indicates adaptation with associated deficit in sensory and motor function. The increased ALFF in subacute SCI might reflect reorganization processes in the subacute phase.


Subject(s)
Graft vs Host Disease , Sensorimotor Cortex , Spinal Cord Injuries , Humans , Spinal Cord Injuries/diagnostic imaging , Cerebellum/diagnostic imaging , Occipital Lobe
5.
J Ultrasound Med ; 33(12): 2099-103, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25425365

ABSTRACT

OBJECTIVES: An important sign of proximal intersection syndrome is thickening of the tendons at the area where the first extensor compartment tendons cross over the second compartment. Normal values for the thickness of the tendons have not been reported. Our purpose was to measure the thickness of the tendons with sonography at the level of the intersection in healthy volunteers and assess differences between men and women, dominant and nondominant sides, and different tendons. METHODS: Forty-one asymptomatic volunteers (25 women and 16 men) were examined by 2 radiologists experienced in musculoskeletal sonography. The thickness of the tendons in the first and second compartments was measured at their intersection at standardized proximal and distal levels. Descriptive statistics were obtained. Differences between men and women, dominant and nondominant sides, and different tendons were evaluated by a Student t test. RESULTS: The 95% confidence intervals for measurements of superimposed tendon groups varied between 0.30 and 0.40 cm in women and between 0.36 and 0.48 cm in men. There were no statistically significant differences in comparisons of the different tendon groups (P > .05). There were statistically significant differences (P < .05) between tendon thickness in men and women except for the right extensor carpi radialis longus + abductor pollicis longus (proximal measurement) and extensor carpi radialis brevis + extensor pollicis brevis (distal measurement). On comparison of dominant and nondominant sides, there were no statistically significant differences. CONCLUSIONS: Normal tendon thickness should be between 0.30 and 0.40 cm in women and 0.36 and 0.48 cm in men. A comparison between asymptomatic and symptomatic sides and proximal and distal measurements is recommended.


Subject(s)
Functional Laterality/physiology , Tendons/diagnostic imaging , Tendons/physiology , Ultrasonography/methods , Adult , Female , Humans , Male , Middle Aged , Organ Size , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Sex Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...