Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Chemosphere ; : 142806, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986783

ABSTRACT

A gas chromatography coupled to high-resolution mass spectrometry (GC-HR/MS) has been used as the standard method for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDDs/Fs), which are regulated at screening and action levels in the environment. However, several alternative methods have been attempted due to the disadvantage of its high cost. Although a gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS) has been used in a wide variety of sample matrices, showing that they are interchangeable, there has been a lack of comprehensive studies on statistical agreement with GC-HR/MS. In this study, a pairwise comparison of the total concentrations of PCDDs/Fs in 90 soil field samples obtained by two mass spectrometric methods was performed using the Passing-Bablok (P&B) regression and Bland-Altman (B&A) analysis for the method comparison. According to the result of the B&A analysis, the concentration range of PCDDs/Fs was between 98.2 and 1760 pg/g showed good agreement between two methods at the 95 % confidence level (CL). Although there was a large discrepancy between the two methods in the low concentrations (< 16.5 pg/g of PCDDs/Fs), this result was similar to the P&B regression analysis. As the verification results by B&A and P&B regression analysis, the interchangeable concentration range between the two methods was confirmed to be adequate for the monitoring of PCDDs/Fs regulating levels in soils.

2.
Toxics ; 11(9)2023 Aug 28.
Article in English | MEDLINE | ID: mdl-37755748

ABSTRACT

Soils contaminated with polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and dioxin-like (dl) polychlorinated biphenyls (PCBs), known as persistent organic pollutants (POPs), have garnered global attention because of their toxicity and persistence in the environment. The standard method for target analytes has been used; however, it is an obstacle in large-scale sample analysis due to the comprehensive sample preparation and high-cost instrumental analysis. Thus, analytical development of inexpensive methods with lower barriers to determine PCDDs/Fs and dl-PCBs in soil is needed. In this study, a one-step cleanup method was developed and validated by combining a multilayer silica gel column and Florisil micro-column followed by gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS). To optimize the separation and quantification of 17 PCDDs/Fs and 12 dl-PCBs in soils, the sample cleanup and instrumental conditions were investigated. For quantification method validation, spiking experiments were conducted to determine the linearity of the calibration, recovery, and method detection limit of PCDDs/Fs and dl-PCBs using isotopic dilution GC-QqQ-MS/MS. The applicability of the simultaneous determination of PCDDs/Fs and dl-PCBs was confirmed by the recovery of native target congeners and labeled surrogate congeners spiked into the quality-control and actual soil samples. The results were in good agreement with the requirements imposed by standard methods. The findings in this work demonstrated the high accessibility of the sample cleanup and analysis methods for the efficient determination of PCDDs/Fs and dl-PCBs in contaminated soils.

3.
J Nanosci Nanotechnol ; 13(12): 8055-8, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24266190

ABSTRACT

Cobalt nanopatterns are promising assemblies for patterned magnetic storage applications. The fabrication of cobalt magnetic nanostructures on n-tridecylamine x hydrochloride (TDA x HCl) self-assembled monolayer (SAM) modified silicon surfaces using direct writing atomic force microscope (AFM) lithography for localized electrochemical reduction of cobalt ions was demonstrated. The ions were reduced to form metal nanowires along the direction of the electricfield between the AFM tip and the substrate. In this lithography process, TDA x HCI SAMs play an important role in the lithography process for improving the resolution of cobalt nanopatterns by preventing nonspecific reduction of cobalt ions on the unwritten background. Cobalt nanowires and nanodots with width of 225 +/- 26 nm and diameter of 208 +/- 28 nm were successfully fabricated. Platinium-coated polydimethylsiloxane (PDMS) stamp was used fabricating bulk cobalt structures which can be detected by energy dispersive X-ray spectroscopy for element analysis and the physical and magnetic properties of these cobalt nanopatterns were characterized using AFM and magnetic force microscope.

SELECTION OF CITATIONS
SEARCH DETAIL
...