Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Ann Med ; 55(2): 2249936, 2023.
Article in English | MEDLINE | ID: mdl-37683195

ABSTRACT

Objective: To investigate the effect of different bladder filling states on positioning errors in radiotherapy for cervical cancer and obtain the reference range of bladder filling consistency during radiotherapy.Methods: Patients who underwent postoperative radiotherapy for cervical cancer in Nantong Tumor Hospital from October 2018 to December 2019 were selected. According to the bladder filling deviation, they were divided into group A1 (deviation < 20%) and group B1 (deviation ≥ 20%). The bladder filling variations of the two groups were compared with different positioning errors. Group A2 has a positioning error of <0.4 cm, and group B2 has a positioning error of ≥0.4 cm. The reference range of bladder filling consistency during radiotherapy is obtained by analyzing the composition ratio of different positioning errors of bladder filling deviation.Results: This study included 195 patients with cervical cancer. The error of longitudinal and vertical position in group B1 was significantly higher than that in group A1 (0.50 ± 0.34 vs. 0.26 ± 0.22 cm, p < 0.001, and 0.22 ± 0.17 vs. 0.16 ± 0.12 cm, p < 0.001). Compared with group B2, the absolute deviation of bladder filling in group A2 (54.1% ± 54.4% vs. 25.6% ± 22.7%, p < 0.001) was slight. The chi-square test showed significant differences in the proportion of the positioning state of different bladder filling forms (χ2 = 31.006, p < 0.001). In addition, there was a significant difference in the proportion of stability errors in patients with poor stability in different directions (χ2 = 118.551, p < 0.001).Conclusion: In patients with cervical cancer fixed in the supine position, a bladder capacity deviation <20% is easier to achieve excellent positioning with, and it can better control the positioning error of radiotherapy and ensure the positioning accuracy of dose distribution to the target area. It can also achieve good tumor treatment effects. This range can be used as a reference for bladder filling consistency in patients with cervical cancer undergoing radiotherapy.


Subject(s)
Uterine Cervical Neoplasms , Female , Humans , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/surgery , Urinary Bladder/surgery , Hysterectomy , Reference Values
2.
Quant Imaging Med Surg ; 13(5): 2907-2921, 2023 May 01.
Article in English | MEDLINE | ID: mdl-37179916

ABSTRACT

Background: Cone-beam computed tomography (CBCT) is an important tool for patient positioning in radiotherapy due to its outstanding advantages. However, the CBCT registration shows errors due to the limitations of the automatic registration algorithm and the nonuniqueness of manual verification results. The purpose of this study was to verify the feasibility of using the Sphere-Mask Optical Positioning System (S-M_OPS) to improve the registration stability of CBCT through clinical trials. Methods: From November 2021 to February 2022, 28 patients who received intensity-modulated radiotherapy and site verification with CBCT were included in this study. S-M_OPS was used as an independent third-party system to supervise the CBCT registration result in real time. The supervision error was calculated based on the CBCT registration result and using the S-M_OPS registration result as the standard. For the head and neck, patients with a supervision error ≥3 or ≤-3 mm in 1 direction were selected. For the thorax, abdomen, pelvis, or other body parts, patients with a supervision error ≥5 or ≤-5 mm in 1 direction were selected. Then, re-registration was performed for all patients (selected and unselected). The registration errors of CBCT and S-M_OPS were calculated based on the re-registration results as the standard. Results: For selected patients with large supervision errors, CBCT registration errors (mean ± standard deviation) in the latitudinal (LAT; left/right), vertical (VRT; superior/inferior), and longitudinal (LNG; anterior/posterior) directions were 0.90±3.20, -1.70±0.98, and 7.30±2.14 mm, respectively. The S-M_OPS registration errors were 0.40±0.14, 0.32±0.66, and 0.24±1.12 mm in the LAT, VRT, and LNG directions, respectively. For all patients, CBCT registration errors in the LAT, VRT, and LNG directions were 0.39±2.69, -0.82±1.47, and 2.39±2.93 mm, respectively. The S-M_OPS registration errors were -0.25±1.33, 0.55±1.27, and 0.36±1.34 mm for all patients in the LAT, VRT, and LNG directions, respectively. Conclusions: This study shows that S-M_OPS registration offers comparable accuracy to CBCT for daily registration. S-M_OPS, as an independent third-party tool, can prevent large errors in CBCT registration, thereby improving the accuracy and stability of CBCT registration.

3.
Front Oncol ; 12: 918296, 2022.
Article in English | MEDLINE | ID: mdl-36267985

ABSTRACT

Background: The setup accuracy plays an extremely important role in the local control of tumors. The purpose of this study is to verify the feasibility of "Sphere-Mask" Optical Positioning System (S-M_OPS) for fast and accurate setup. Methods: From 2016 to 2021, we used S-M_OPS to supervise 15441 fractions in 1981patients (with the cancer in intracalvarium, nasopharynx, esophagus, lung, liver, abdomen or cervix) undergoing intensity-modulated radiation therapy (IMRT), and recorded the data such as registration time and mask deformation. Then, we used S-M_OPS, laser line and cone beam computed tomography (CBCT) for co-setup in 277 fractions, and recorded laser line-guided setup errors and S-M_OPS-guided setup errors with CBCT-guided setup result as the standard. Results: S-M_OPS supervision results: The average time for laser line-guided setup was 31.75s. 12.8% of the reference points had an average deviation of more than 2 mm and 5.2% of the reference points had an average deviation of more than 3 mm. Co-setup results: The average time for S-M_OPS-guided setup was 7.47s, and average time for CBCT-guided setup was 228.84s (including time for CBCT scan and manual verification). In the LAT (left/right), VRT (superior/inferior) and LNG (anterior/posterior) directions, laser line-guided setup errors (mean±SD) were -0.21±3.13mm, 1.02±2.76mm and 2.22±4.26mm respectively; the 95% confidence intervals (95% CIs) of laser line-guided setup errors were -6.35 to 5.93mm, -4.39 to 6.43mm and -6.14 to 10.58mm respectively; S-M_OPS-guided setup errors were 0.12±1.91mm, 1.02±1.81mm and -0.10±2.25mm respectively; the 95% CIs of S-M_OPS-guided setup errors were -3.86 to 3.62mm, -2.53 to 4.57mm and -4.51 to 4.31mm respectively. Conclusion: S-M_OPS can greatly improve setup accuracy and stability compared with laser line-guided setup. Furthermore, S-M_OPS can provide comparable setup accuracy to CBCT in less setup time.

4.
Technol Cancer Res Treat ; 18: 1533033819825865, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30803363

ABSTRACT

PURPOSE: To develop an infrared optical method of reducing surface-based registration error caused by respiration to improve radiotherapy setup accuracy for patients with abdominal or pelvic tumors. MATERIALS AND METHODS: Fifteen patients with abdominal or pelvic tumors who received radiation therapy were prospectively included in our study. All patients were immobilized with vacuum cushion and underwent cone-beam computed tomography to validate positioning error before treatment. For each patient, after his or her setup based on markers fixed on immobilization device, initial positioning errors in patient left-right, anterior-posterior, and superior-inferior directions were validated by cone-beam computed tomography. Then, our method calculated mismatch between patient and immobilization device based on surface registration by interpolating between expiratory- and inspiratory-phase surface to find the specific phase to best match the surface in planning computed tomography scans. After adjusting the position of treatment couch by the shift proposed by our method, a second cone-beam computed tomography was performed to determine the final positioning error. A comparison between initial and final setup error will be made to validate the effectiveness of our method. RESULTS: Final positioning error confirmed by cone-beam computed tomography is 1.59 (1.82), 1.61 (1.84), and 1.31 (1.38) mm, reducing initial setup error by 24.52%, 51.04%, and 53.63% in patient left-right, anterior-posterior, and superior-inferior directions, respectively. Wilcoxon test showed that our method significantly reduced the 3-dimensional distance of positioning error ( P < .001). CONCLUSION: Our method can significantly improve the setup precision for patients with abdominal or pelvic tumors in a noninvasive way by reducing the surface-based registration error caused by respiration.


Subject(s)
Abdominal Neoplasms/radiotherapy , Patient Positioning , Pelvic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Image-Guided/methods , Respiration , Abdominal Neoplasms/diagnostic imaging , Abdominal Neoplasms/pathology , Cone-Beam Computed Tomography/methods , Female , Humans , Male , Middle Aged , Movement , Pelvic Neoplasms/diagnostic imaging , Pelvic Neoplasms/pathology
5.
Technol Cancer Res Treat ; 16(6): 1187-1193, 2017 12.
Article in English | MEDLINE | ID: mdl-29333959

ABSTRACT

PURPOSE: To minimize the mismatch error between patient surface and immobilization system for tumor location by a noninvasive patient setup method. MATERIALS AND METHODS: The method, based on a point set registration, proposes a shift for patient positioning by integrating information of the computed tomography scans and that of optical surface landmarks. An evaluation of the method included 3 areas: (1) a validation on a phantom by estimating 100 known mismatch errors between patient surface and immobilization system. (2) Five patients with pelvic tumors were considered. The tumor location errors of the method were measured using the difference between the proposal shift of cone-beam computed tomography and that of our method. (3) The collected setup data from the evaluation of patients were compared with the published performance data of other 2 similar systems. RESULTS: The phantom verification results showed that the method was capable of estimating mismatch error between patient surface and immobilization system in a precision of <0.22 mm. For the pelvic tumor, the method had an average tumor location error of 1.303, 2.602, and 1.684 mm in left-right, anterior-posterior, and superior-inferior directions, respectively. The performance comparison with other 2 similar systems suggested that the method had a better positioning accuracy for pelvic tumor location. CONCLUSION: By effectively decreasing an interfraction uncertainty source (mismatch error between patient surface and immobilization system) in radiotherapy, the method can improve patient positioning precision for pelvic tumor.


Subject(s)
Multimodal Imaging/methods , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiotherapy, Image-Guided , Humans , Neoplasms/pathology , Patient Positioning , Phantoms, Imaging , Radiosurgery , Radiotherapy Planning, Computer-Assisted , Radiotherapy Setup Errors , Tomography, X-Ray Computed
6.
Zhonghua Yi Xue Za Zhi ; 91(40): 2841-4, 2011 Nov 01.
Article in Chinese | MEDLINE | ID: mdl-22333546

ABSTRACT

OBJECTIVE: To explore the clinical therapeutic efficacies of combined three-dimensional conformal radiotherapy (3DCRT) plus transcatheter arterial chemoembolization (TACE) for portal vein tumor thrombus (PVTT) in hepatocellular carcinoma (HCC). METHODS: A total of 145 HCC patients with tumor thrombus in portal vein were divided randomly into 2 groups. Group A (n = 64) was treated with surgical intervention alone while group B (n = 81) underwent 3DCRT plus TACE. The gross tumor volume (GTV) was defined as PVTT only. RESULTS: Survival rates of group A at year 1 and 2 were 40.3% and 21.9% with a mean survival time (MST) of 15.2 months while that of group B were 41.2% and 22.5% with a MST of 15.8 months. The total effective rates of groups A and B was 40.6% (28/64) and 44.4% (36/81) respectively. CONCLUSION: The therapeutic efficacy of 3DCRT plus TACE is similar to that of surgical intervention.


Subject(s)
Carcinoma, Hepatocellular/therapy , Embolization, Therapeutic , Liver Neoplasms/therapy , Radiotherapy, Conformal/methods , Thrombosis/pathology , Adult , Aged , Carcinoma, Hepatocellular/pathology , Combined Modality Therapy , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Neoplastic Cells, Circulating , Portal Vein/pathology , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...