Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Type of study
Publication year range
1.
Cancer Radiother ; 26(3): 427-432, 2022 May.
Article in English | MEDLINE | ID: mdl-34090790

ABSTRACT

PURPOSE: To use statistical process control for intensity-modulated radiation therapy (IMRT) quality assurance (QA) and improve tolerance limits and action limits. METHODS: An electronic portal imaging device (EPID) was selected to verify IMRT QA. The I-chart and the exponentially weighted moving averages (EWMA) chart were used to analyze the corresponding results. RESULTS: Twenty samples were used to enable the sampling requirements for building the control limits to be met. The I-chart showed that isolated data points beyond the control limits were mainly derived from complex plans. The EWMA made predictions of systematic errors earlier than the I-chart. Systematic errors primarily originated from the dose calibration on the EPID, and recalibrating the EPID could eliminate such errors. CONCLUSION: Statistical process control is an effective tool to detect controllable and can be used in IMRT QA. After calibrating the EPID, the tolerance and action limits all improved and satisfied the requirements/recommended values of the AAPM TG-218 report.


Subject(s)
Radiotherapy, Intensity-Modulated , Humans , Palliative Care , Quality Assurance, Health Care/methods , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
2.
Se Pu ; 19(3): 286-8, 2001 May.
Article in Chinese | MEDLINE | ID: mdl-12541822

ABSTRACT

The method developed is based on the special property that ethephon can be easily decomposed into ethene in alkaline solution by heating. Certain amount of concentrated KOH solution was added to the sample and heated at 70 degrees C. Then, 1 mL of the gas above the sample was injected into a gas chromatograph by head-space sampler for the determination of the target compound with external standard quantitation method. The detection limit was 0.025 mg/kg and the fortified recoveries of ethephon in concentrated pineapple juice (60 +/- 1) Brix at the range of 0.1 mg/kg-10 mg/kg were 92%-98% (n = 8, for each level). The relative standard deviations were 3.99%-7.94%.


Subject(s)
Beverages/analysis , Chromatography, Gas/methods , Organophosphorus Compounds/analysis , Pesticide Residues/analysis , Plant Growth Regulators/analysis , Ananas
SELECTION OF CITATIONS
SEARCH DETAIL
...